Browsing by Author "Hsieh, Cheng-Huan"
Now showing 1 - 3 of 3
- Results Per Page
- Sort Options
Item type:Item, Automatic Sampling and Analysis of Organics and Biomolecules by Capillary Action-Supported Contactless Atmospheric Pressure Ionization Mass Spectrometry(2013-06-06) ;Hsieh, Cheng-Huan ;Meher, Anil Kumar ;Chen, Yu-Chie ;應用化學系Department of Applied ChemistryContactless atmospheric pressure ionization (C-API) method has been recently developed for mass spectrometric analysis. A tapered capillary is used as both the sampling tube and spray emitter in C-API. No electric contact is required on the capillary tip during C-API mass spectrometric analysis. The simple design of the ionization method enables the automation of the C-API sampling system. In this study, we propose an automatic C-API sampling system consisting of a capillary (similar to 1 cm), an aluminium sample holder, and a movable XY stage for the mass spectrometric analysis of organics and biomolecules. The aluminium sample holder is controlled by the movable XY stage. The outlet of the C-API capillary is placed in front of the orifice of a mass spectrometer, whereas the sample well on the sample holder is moved underneath the capillary inlet. The sample droplet on the well can be readily infused into the C-API capillary through capillary action. When the sample solution reaches the capillary outlet, the sample spray is readily formed in the proximity of the mass spectrometer applied with a high electric field. The gas phase ions generated from the spray can be readily monitored by the mass spectrometer. We demonstrate that six samples can be analyzed in sequence within 3.5 min using this automatic C-API MS setup. Furthermore, the well containing the rinsing solvent is alternately arranged between the sample wells. Therefore, the C-API capillary could be readily flushed between runs. No carryover problems are observed during the analyses. The sample volume required for the C-API MS analysis is minimal, with less than 1 nL of the sample solution being sufficient for analysis. The feasibility of using this setup for quantitative analysis is also demonstrated.Item type:Item, Capillary Action-Supported Contact less Atmospheric Pressure Ionization for the Combined Sampling and Mass Spectrometric Analysis of Biomolecules(2011-04-15) ;Hsieh, Cheng-Huan ;Chang, Chia-Hsien ;Urban, Pawel L. ;Chen, Yu-Chie應用化學系It is proposed that a short tapered capillary can be utilized as a nanoliter-volume sampling tool and sample emitter for generation of gas-phase ions in front of the mass spectrometer, without the need for using an additional electric power supply, a gas supply, or a syringe pump. A wide range of molecules can be analyzed in pure solutions and complex matrixes (cell extract, urine, and plant tissue) with no or minimum sample preparation. Singly and multiply charged ions can be detected in either positive or negative-ion mode. Because of the nanoliter-volume sampling and low spectral background, the mass detection limit for bradykinin is in the low attomole range. Other advantages include simplicity, disposability, and low cost. The putative mechanism of the ion formation in this capillary-action supported contactless spray emitter is discussed.Item type:Item, Online monitoring of chemical reactions by contactless atmospheric pressure ionization mass spectrometry(2012-05-01) ;Hsieh, Cheng-Huan ;Chao, Chin-Sheng ;Mong, Kwok-Kong Tony ;Chen, Yu-Chie應用化學系