Browsing by Author "Huang, Tony"
Now showing 1 - 3 of 3
- Results Per Page
- Sort Options
Item type:Item, Deviatoric deformation kinetics in high entropy alloy under hydrostatic compression(2019-07-05) ;Huang, E-Wen ;Lin, Chih-Ming ;Juang, Jenh-Yih ;Chang, Yao-JenChang, Yuan-WeiAn equiatomic CoCrFeMnNi high-entropy alloy under hydrostatic compression is investigated using insitu angular-dispersive X-ray diffraction to explore the polymorphism in high entropy alloy systems. The metallic system is of face-centered-cubic structure at ambient condition and applied hydrostatic pressures up to 20 GPa via diamond anvil cell. The angle-resolved diffraction-intensity evolutions of multiple diffraction peaks were collected simultaneously to elucidate the phase stability examinations. The phase transformation from face-centered-cubic to hexagonal-close-packed structure was evidently observed in CoCrFeMnNi alloy accompanied by a deviatoric strain subjected to the hydrostatic compression. We found lattice-asymmetric crossover before and after the phase transformation subjected to hydrostatic compression surroundings. Deviatoric strain triggers fcc-hcp phase transformation as local heterogeneity-driven lattice distortion is significant for CoCrFeMnNi alloy. (c) 2019 The Authors. Published by Elsevier B.V.Item type:Item, Effectiveness of holographic optical element module sensor in measuring blood prothrombin time(2014-07-01) ;Lin, Yu-Cheng ;Yen, Shih-Chieh ;Cheng, Stone ;Huang, Tony機械工程學系A small-form-factor holographic optical element (HOE) module, which was mounted on a dual-stage seesaw actuator, was utilized to evaluate blood coagulation in real time. The method involved assessing the decrease in transmitted light of the blood sample surface when the clotting is formed. The prothrombin time (PT) was measured by illumining and focusing a 635 nm laser beam onto the sample. As the fibrinogen turned into non-solute fibrin, the transmitted efficiency and total intensity of the reflected light from the reflector changed. A low-pass filter suppressed the noise in the coagulation-related transient response to yield accurate signals. Finally, the PT measurements were compared to those made classically using other optical sensors.Item type:Item, Effectiveness of holographic optical element module sensor in measuring blood prothrombin time(2014-07-01) ;Lin, Yu-Cheng ;Yen, Shih-Chieh ;Cheng, Stone ;Huang, Tony機械工程學系A small-form-factor holographic optical element (HOE) module, which was mounted on a dual-stage seesaw actuator, was utilized to evaluate blood coagulation in real time. The method involved assessing the decrease in transmitted light of the blood sample surface when the clotting is formed. The prothrombin time (PT) was measured by illumining and focusing a 635 nm laser beam onto the sample. As the fibrinogen turned into non-solute fibrin, the transmitted efficiency and total intensity of the reflected light from the reflector changed. A low-pass filter suppressed the noise in the coagulation-related transient response to yield accurate signals. Finally, the PT measurements were compared to those made classically using other optical sensors.