Browsing by Author "Hung, Shao-Ming"
Now showing 1 - 3 of 3
- Results Per Page
- Sort Options
Item type:Item, Evaluation of a novel personal nanoparticle sampler(2014-02-01) ;Zhou, Yue ;Irshad, Hammad ;Tsai, Chuen-Jinn ;Hung, Shao-MingCheng, Yung-SungThis work investigated the performance in terms of collection efficiency and aspiration efficiency of a personal sampler capable of collecting ultrafine particles (nanoparticles) in the occupational environment. This sampler consists of a cyclone for respirable particle classification, micro-orifice impactor stages with an acceleration nozzle to achieve nanoparticle classification and a backup filter to collect nanoparticles. Collection efficiencies of the cyclone and impactor stages were determined using monodisperse polystyrene latex and silver particles, respectively. Calibration of the cyclone and impactor stages showed 50% cut-off diameters of 3.95 mu m and 94.7 nm meeting the design requirements. Aspiration efficiencies of the sampler were tested in a wind tunnel with wind speeds of 0.5, 1.0, and 1.5 m s(-1). The test samplers were mounted on a full size mannequin with three orientations toward the wind direction (0 degrees, 90 degrees, and 180 degrees). Monodisperse oleic acid aerosols tagged with sodium fluorescein in the size range of 2 to 10 mu m were used in the test. For particles smaller than 2 mu m, the fluorescent polystyrene latex particles were generated by using nebulizers. For comparison of the aspiration efficiency, a NIOSH two-stage personal bioaerosol sampler was also tested. Results showed that the orientation-averaged aspiration efficiency for both samplers was close to the inhalable fraction curve. However, the direction of wind strongly affected the aspiration efficiency. The results also showed that the aspiration efficiency was not affected by the ratio of free-stream velocity to the velocity through the sampler orifice. Our evaluation showed that the current design of the personal sampler met the designed criteria for collecting nanoparticles <= 100 nm in occupational environments.Item type:Item, Field Application of a Newly Developed Personal Nanoparticle Sampler to Selected Metalworking Operations(2013-06-01) ;Young, Li-Hao ;Lin, Yun-Hua ;Lin, Tzu-Hsien ;Tsai, Perng-JyWang, Ying-FangA personal nanoparticle sampler (PENS) that simultaneously collects respirable particles (< 4 mu m) and nanoparticles (< 0.1 mu m) has recently been developed and calibrated in the laboratory. This study aims to evaluate the performance of the PENS in the workplace, and to determine the exposure characteristics during selected metalworking operations. Metal polishing/buffing, spot welding, and milling operations were selected to represent sources of solid metal particles, fume aggregates and metalworking fluid mists, respectively. In each operation, personal samples of a side-by-side PENS and SKC respirable dust aluminum cyclone were taken concurrently with ambient particle number size distribution measurements. The PENS-measured respirable particle mass concentrations (PM4) showed remarkable accuracy with respect to the reference SKC cyclone, regardless of particle type. The PENS-derived nanoparticle effective densities agreed reasonably well with the bulk densities expected for the substrate and materials in use. During the metalworking operations, the nanoparticle mass concentrations (PM0.1) were poorly associated with the PM4 but strongly correlated with the ambient nanoparticle number concentrations (PN0.1), due to the persistent, elevated levels of nanoparticles formed during the operations. Overall, these results suggest that the PENS is applicable for use in the workplace to assess respirable and nanoparticle personal exposure, and that metal polishing/buffing, welding and milling generate a considerable amount of nanoparticles.Item type:Item, Novel Active Personal Nanoparticle Sampler for the Exposure Assessment of Nanoparticles in Workplaces(2012-04-17) ;Tsai, Chuen-Jinn ;Liu, Chun-Nan ;Hung, Shao-Ming ;Chen, Sheng-ChiehUang, Shi-NianA novel active personal nanoparticle sampler (PENS), which enables the collection of both respirable particulate mass (RPM) and nanoparticles (NPs) simultaneously, was developed to meet the critical demand for personal sampling of engineered nanomaterials (ENMs) in workplaces. The PENS consists of a respirable cyclone and a micro-orifice impactor with the cutoff aerodynamic diameter (d(pa50)) of 4 mu m and 100 nm, respectively. The micro-orifice impactor has a fixed micro-orifice plate (137 nozzles of 55 mu m in the inner diameter) and a rotating, silicone oil-coated Teflon filter substrate at 1 rpm to achieve a uniform particle deposition and avoid solid particle bounce. A final filter is used after the impactor to collect the NPs. Calibration results show that the d(pa50) of the respirable cyclone and the micro-orifice impactor are 3.92 +/- 0.22 mu m and 101.4 +/- 0.1 nm, respectively. The d(pa50) at the loaded micro-Al2O3 mass of 0.36-3.18 mg is shifted to 102.9-101.2 nm, respectively, while it is shifted to 98.9-97.8 nm at the loaded nano-TiO2 mass of 0.92-1.78 mg, respectively. That is, the shift of d(pa50) due to solid particle loading is small if the PENS is not overloaded. Both NPs and RPM concentrations were found to agree well with those of the IOSH respirable cyclone and MOUDI. By using the present PENS, the collected samples can be further analyzed for chemical species concentrations besides gravimetric analysis to determine the actual exposure concentrations of ENMs in both RPM and NPs fractions in workplaces, which are often influenced by the background or incident pollution sources.