Browsing by Author "Kuo, Wen-Chuan"
Now showing 1 - 2 of 2
- Results Per Page
- Sort Options
Item type:Item, New insight on optical and magnetic Fe3O4 nanoclusters promising for near infrared theranostic applications(2015-01-01) ;Huang, Chih-Chia ;Chang, Po-Yang ;Liu, Chien-Liang ;Xu, Jia-PuWu, Shu-PaoExtensive efforts have been devoted to the development of a new biophotonic system using near infrared (NIR) nano-agents for non-invasive cancer diagnosis and therapy. Here, we developed a simple synthesis reaction of ligands, hydrazine, and iron(II) chloride to fabricate Fe3O4 cluster-structured nanoparticles (CNPs) with interesting NIR photonics and high magnetization (M-s: 98.3 emu g(-1) and proton relaxivity r(2): 234.6 mM(-1) s(-1)). These Fe3O4 CNPs exhibited optical absorption and reflection over all wavelengths, showing a U-shape absorption band with a low absorbance at a range of 750-950 nm and a progressive evolution in the second near infrared region. Strengthening of the scattering effect by incubating Fe3O4 CNPs with HeLa cells was observed when optical contrast enhancement was performed in an optical coherence tomography (OCT) microscope system with a laser light source at 860 nm. Using a 1064 nm laser at a low power density (380 mW cm(-2)) to excite the Fe3O4 CNPs (375 ppm([Fe])) led to a rise in the water temperature from 25 degrees C to 58 degrees C within 10 min. Finally, we present the first example of magneto-motive OCT cellular imaging combined with enhanced photothermal therapy using Fe3O4 CNPs and applying a magnetic field, which is promising for preclinical and clinical trials in the future.Item type:Item, Supercontinuum source-based multi-contrast optical coherence tomography for rat retina imaging(2018-12-01) ;Syu, Jia-Pu ;Buddhakosai, Waradee ;Chen, Shih-Jen ;Ke, Chang-ChihChiou, Shih-HwaThis study proposed an ultrahigh-resolution multi-contrast optical coherence tomography system integrated with fundus photography for in vivo retinal imaging of rodents. A supercontinuum light source was used in the system, providing an axial resolution of less than 3 mu m within 1.8 mm (in the tissue). Three types of tissue contrast based on backscattered intensity, phase retardation, and microvasculature at a capillary level can be simultaneously obtained using the proposed system. Pigmented Long-Evans, non-pigmented (albino) Sprague Dawley, and Royal College of Surgeons rats were imaged and compared. In vivo imaging results were validated with histology. (C) 2018 Optical Society of America under the terms of the OSA Open Access Publishing Agreement