Browsing by Author "Lee, Cheng-Hung"
Now showing 1 - 4 of 4
- Results Per Page
- Sort Options
Item type:Item, Biomechanical analysis of acromioclavicular joint dislocation treated with clavicle hook plates in different lengths(2015-11-01) ;Shih, Cheng-Min ;Huang, Kui-Chou ;Pan, Chien-Chou ;Lee, Cheng-HungSu, Kuo-ChihClavicle hook plates are frequently used in clinical orthopaedics to treat acromioclavicular joint dislocation. However, patients often exhibit acromion osteolysis and per-implant fracture after undergoing hook plate fixation. With the intent of avoiding future complications or fixation failure after clavicle hook plate fixation, we used finite element analysis (FEA) to investigate the biomechanics of clavicle hook plates of different materials and sizes when used in treating acromioclavicular joint dislocation. Using finite element analysis, this study constructed a model comprising four parts: clavicle, acromion, clavicle hook plate and screws, and used the model to simulate implanting different types of clavicle hook plates in patients with acromioclavicular joint dislocation. Then, the biomechanics of stainless steel and titanium alloy clavicle hook plates containing either six or eight screw holes were investigated. The results indicated that using a longer clavicle hook plate decreased the stress value in the clavicle, and mitigated the force that clavicle hook plates exert on the acromion. Using a clavicle hook plate material characterized by a smaller Young\'s modulus caused a slight increase in the stress on the clavicle. However, the external force the material imposed on the acromion was less than the force exerted on the clavicle. The findings of this study can serve as a reference to help orthopaedic surgeons select clavicle hook plates.Item type:Item, Biomechanical Analysis of Implanted Clavicle Hook Plates With Different Implant Depths and Materials in the Acromioclavicular Joint: A Finite Element Analysis Study(2016-11) ;Lee, Cheng-Hung ;Shih, Cheng-Min ;Huang, Kui-Chou ;Chen, Kun-HuiHung, Li-KunClinical implantation of clavicle hook plates is often used as a treatment for acromioclavicular joint dislocation. However, it is not uncommon to find patients that have developed acromion osteolysis or had peri-implant fracture after hook plate fixation. With the aim of preventing complications or fixation failure caused by implantation of inappropriate clavicle hook plates, the present study investigated the biomechanics of clavicle hook plates made of different materials and with different hook depths in treating acromioclavicular joint dislocation, using finite element analysis (FEA). This study established four parts using computer models: the clavicle, acromion, clavicle hook plate, and screws, and these established models were used for FEA. Moreover, implantations of clavicle hook plates made of different materials (stainless steel and titanium alloy) and with different depths (12, 15, and 18mm) in patients with acromioclavicular joint dislocation were simulated in the biomechanical analysis. The results indicate that deeper implantation of the clavicle hook plate reduces stress on the clavicle, and also reduces the force applied to the acromion by the clavicle hook plate. Even though a clavicle hook plate made of titanium alloy (a material with a lower Young\'s modulus) reduces the force applied to the acromion by the clavicle hook plate, slightly higher stress on the clavicle may occur. The results obtained in this study provide a better reference for orthopedic surgeons in choosing different clavicle hook plates for surgery.Item type:Item, Decision Support for the Optimization of Provider Staffing for Hospital Emergency Departments with a Queue-Based Approach(2019-12-01) ;Jiang, Fuu-Cheng ;Shih, Cheng-Min ;Wang, Yun-Ming ;Yang, Chao-TungChiang, Yi-JuDeployment or distribution of valuable medical resources has emerged as an increasing challenge to hospital administrators and health policy makers. The hospital emergency department (HED) census and workload can be highly variable. Improvement of emergency services is an important stage in the development of the healthcare system and research on the optimal deployment of medical resources appears to be an important issue for HED long-term management. HED performance, in terms of patient flow and available resources, can be studied using the queue-based approach. The kernel point of this research is to approach the optimal cost on logistics using queuing theory. To model the proposed approach for a qualitative profile, a generic HED system is mapped into the M/M/R/N queue-based model, which assumes an R-server queuing system with Poisson arrivals, exponentially distributed service times and a system capacity of N. A comprehensive quantitative mathematical analysis on the cost pattern was done, while relevant simulations were also conducted to validate the proposed optimization model. The design illustration is presented in this paper to demonstrate the application scenario in a HED platform. Hence, the proposed approach provides a feasibly cost-oriented decision support framework to adapt a HED management requirement.Item type:Item, Roles of impaired intracellular calcium cycling in arrhythmogenicity of diabetic mouse model(2017-10-01) ;Chou, Chung-Chuan ;Ho, Chien-Te ;Lee, Hui-Ling ;Chu, YenYen, Tzung-HaiBackgroundDiabetes mellitus is associated an increased risk of ventricular arrhythmias (VAs), but the underlying electrophysiological mechanisms are not fully explored. This study was aimed to test whether dynamic factors and Ca-i handling play roles in arrhythmogenesis of a diabetic animal model. Methods: We used 26 db/db type 2 diabetes mice and 28 control mice in this study. VA inducibility was evaluated in vivo under isoflurane general anesthesia. The intracellular Ca2+ (Ca-i) and membrane voltage (V-m) signals of the Langendorff-perfused mouse hearts were simultaneously recorded using the optical mapping technique. Action potential duration (APD), Ca-i dynamics conduction velocity (CV), and arrhythmogenic alternans were analyzed. Western blot was conducted to examine expressions of calcium handling and associated ion channels proteins. Results: The diabetic db/db mice showed significantly increased VA inducibility and severity. Longer APD and Ca-i transient duration and slower Ca-i decay and CV in the db/db mice than these in the control ones were observed. Dynamic pacing showed increased incidence of spatially discordant alternans leading to more VA inducibility in the db/db mice. Western blot analyses revealed increased phosphorylated-Ca2+/calmodulin-dependent protein kinase II protein expression and decreased ryanodine receptor protein expression, which probably underlay the molecular mechanisms of enhanced arrhythmogenicity in db/db mice. Conclusions: The type 2 diabetic mouse hearts show impaired repolarization, Ca-i handling homeostasis, and cardiac conduction reserve, leading to vulnerability of spatially discordant alternans development and induction of VA. Altered Ca-i-handling protein expressions probably underlie the molecular mechanisms of arrhythmogenicity in the type 2 diabetes animal model.