Browsing by Author "Li, Jianqing"
Now showing 1 - 3 of 3
- Results Per Page
- Sort Options
Item type:Item, Development of Novel Hearing Aids by Using Image Recognition Technology(2019-05-01) ;Lin, Bor-Shing ;Liu, Ching-Feng ;Cheng, Chih-Jen ;Wang, Jhi-JoungLiu, ChengyuSpeech is easily affected by different background noise in real environment to reduce the speech intelligibility, in particular, for hearing impaired listeners. In order to improve the above issue, several hearing aids have been developed to enhance the speech signal in noisy environment. Most of current hearing aids were designed to enhance the component of speech and suppress the component of noise. However, it is difficult to separate other speech sources. Adaptive signal enhancement with the beamforming technique might improve the above issue. However, how to distinguish the location of the desired speaker effectively is still a difficult challenge for adaptive beamforming method. A novel concept of hearing aid was proposed in this study. Different from the beamforming-based hearing aids, which use the cross-correlation-coefficient method to estimate time difference of arrival (TDOA), an image recognition technology was used to estimate the location of the desired speaker to obtain the more precise TDOA. An adaptive signal enhancement was also used to enhance the noisy speech sound. From the experimental results, the proposed system could provide a smaller absolute error of TDOA less than 1.25 x 10(-4) ms, and a clear speech sound from the target speaker who the user wants to listen to.Item type:Item, Effects of Inferior Myocardial Infarction Sizes and Sites on Simulated Electrocardiograms Based on a Torso-Heart Model(2019-01-01) ;Cai, Zhipeng ;Li, Jianqing ;Luo, Kan ;Lin, Bor-ShyhWang, ZhigangMyocardial infarction (MI) is one of the major causes of death. Thus, understanding the underlying mechanisms of MI and its clinical features, especially its relationship with common electrocardiography measurements, is important. Heart modeling provides a possible method to simulate certain heart conditions. In this paper, a refined MI torso-heart model was proposed to explore the effect of inferior MI on simulated electrocardiograms. This model simulated the electrical activity of a normal heart and an inferior MI heart at three sites (basal, middle, and apical) with three MI sizes (small, moderate, and large), aiming to investigate the effect of inferior MI on the simulated electrocardiograms. Simulated body surface potential maps were compared with clinical body surface potential maps to verify the effciency of the model. A new measure, namely, the normalized variation coeffcient, was proposed for result evaluation. The results showed that the augmented unipolar left lower limb lead was the best choice for inferior MI diagnoses and it showed the most obvious electrocardiography signal differences between normal and inferior MI hearts. The simulation results corresponded well with commonly used clinical diagnostic criteria. Thus, the proposed refined MI torso-heart model provides a finite element simulation method for quantifying the effects of inferior MI on a torso-heart model-based electrocardiogram and has good potential for use in optimizing electrocardiogram detection.Item type:Item, Noise Rejection for Wearable ECGs Using Modeified Frequency Slice Wavelet Transform and Convolutional Neural Networks(2019-01-01) ;Zhao, Zhongyao ;Liu, Chengyu ;Li, Yaowei ;Li, YixuanWang, JingyuProgress in wearable techniques makes the long-term daily electrocardiogram (ECG) monitoring possible. However, the long-term wearable ECGs can be significantly contaminated by various noises, which affect the detection and diagnosis of cardiovascular diseases (CVDs). The situation becomes more serious for wearable ECG screening, where the data are huge, and doctors have no way to visually check the signal quality episode-by-episode. Therefore, automatic and accurate noise rejection for the wearable big-data ECGs is craving. This paper addressed this issue and proposed a noise rejection method for wearable ECGs based on the combination of modified frequency slice wavelet transform (MFSWT) and convolutional neural network (CNN). Wearable ECGs were recorded using the newly developed 12-lead Lenovo smart ECG vest with a sample rate of 500 Hz and a resolution of 16 bit. One thousand 10-s ECG segments were picked up and were manually labeled into three quality types: clinically useful segments with good signal quality (type A), clinically useful segments with poor signal quality (type B), and clinically useless segments (pure noises, type C). Each of the 1,000 10-s ECG segments were transformed into a 2-D time-frequency (T-F) image using the MFSWT, with a pixel size of 200x50. Then, the 2-D grayscale images from MFSWT were fed into a 13-layer CNN model for training the classification models. Results from the standard 5-folder cross-validation showed that the proposed combination method of MFSWT and CNN achieved a highest classification accuracy of 86.3%, which was higher than the comparable methods from continuous wavelet transform (CWT) and artificial neural networks (ANN). The combination of MFSWT and CNN also had a good calculation efficiency. This paper indicated that the combination of MFSWT and CNN is a potential method for automatic identification of noisy segments from wearable ECG recordings.