Browsing by Author "Li, K. W."
Now showing 1 - 3 of 3
- Results Per Page
- Sort Options
Item type:Item, Saturated flow boiling heat transfer of R-407C and associated bubble characteristics in a narrow annular duct(2008-07-15) ;Hsieh, F. C. ;Li, K. W. ;Lie, Y. M. ;Chen, C. A.Lin, T. F.Experiments are conducted here to investigate how the channel size affects the R-407C saturated flow boiling heat transfer and associated bubble characteristics in a horizontal narrow annular duct. The gap of the duct is fixed at 1.0 and 2.0 mm in this study. The measured data indicate that the saturated flow boiling heat transfer coefficient increases with a decrease in the duct gap. Besides, raising the imposed heat flux can cause a significant increase in the boiling heat transfer coefficients. However, the effects of the refrigerant mass flux and saturated temperature on the boiling heat transfer coefficient are milder. The results from the flow visualization show that the mean diameter of the bubbles departing from the heating surface decreases noticeably at increasing R-407C mass flux. Moreover, the bubble departure frequency increases at reducing duct size and at a high imposed heat flux many bubbles generated from the cavities in the heating surface tend to merge together to form big bubbles. Meanwhile comparison of the present heat transfer data for R-407C with R-134a in the same duct and with some existing correlations is conducted. Furthermore, correlation for the present R-407C saturated flow boiling heat transfer data is proposed. Additionally, the present data for some quantitative bubble characteristics such as the mean bubble departure diameter and frequency and the active nucleation site density are also correlated. (C) 2008 Elsevier Ltd. All rights reserved.Item type:Item, Saturated flow boiling heat transfer of R-410A and associated bubble characteristics in a narrow annular duct(2011-11-01) ;Chen, C. A. ;Li, K. W. ;Lie, Y. M. ;Lin, T. F.機械工程學系Experiments are conducted here to investigate how the channel size affects the R-410A saturated flow boiling heat transfer and associated bubble characteristics in a horizontal narrow annular duct. The gap of the duct is fixed at 1.0 and 2.0 mm in this study. The measured data indicate that the saturated flow boiling heat transfer coefficient increases with increasing refrigerant mass flux and saturated temperature and with a decrease in the gap size. Besides, raising the imposed heat flux can cause a significant increase in the boiling heat transfer coefficient. The results from the flow visualization show that the mean diameter of the bubbles departing from the heating surface decreases slightly with increasing refrigerant mass flux and saturated temperature. Moreover, the bubble departure frequency increases at reducing duct size and increasing mass flux. And at a high imposed heat flux many bubbles generated from the cavities in the heating surface tend to merge together to form big bubbles. Meanwhile, comparisons of the present heat transfer data for R-410A with R-407C and R-134a in the same duct and with some existing correlations are conducted. Furthermore, an empirical correlation for the present R-410A saturated flow boiling heat transfer data is proposed. (C) 2011 Elsevier Ltd. All rights reserved.Item type:Item, Subcooled flow boiling heat transfer of R-407C and associated bubble characteristics in a narrow annular duct(2009-06-01) ;Chen, C. A. ;Chang, W. R. ;Li, K. W. ;Lie, Y. M.Lin, T. F.An experiment is conducted here to investigate how the channel size affects the subcooled flow boiling heat transfer and the associated bubble characteristics of refrigerant R-407C in a horizontal narrow annular duct with the gap of the duct fixed at 1.0 and 2.0 mm. The measured boiling curves indicate that the temperature overshoot at ONB is relatively significant for the subcooled flow boiling of R-407C in the duct. Besides, the subcooled flow boiling heat transfer coefficient increases with a reduction in the duct gap, but decreases with an increase in the inlet liquid subcooling. Moreover, raising the heat flux imposed on the duct can cause a significant increase in the boiling heat transfer coefficients. However, the effects of the refrigerant mass flux and saturated temperature on the boiling heat transfer coefficient are slighter. Visualization of the subcooled flow boiling processes in the duct reveals that the bubbles are suppressed to become smaller and less dense by raising the refrigerant mass flux and inlet subcooling. Raising the imposed heat flux, however, produces positive effects on the bubble population, coalescence and departure frequency. Meanwhile, the present heat transfer data for R-407C are compared with the R-134a data measured in the same duct and with some existing correlations. We also propose empirical correlations for the present data for the R-407C subcooled flow boiling heat transfer and some quantitative bubble characteristics such as the mean bubble departure diameter and frequency and the active nucleation site density. (C) 2009 Elsevier Ltd. All rights reserved.