Item type:Item, An efficient venturi scrubber system to remove submicron particles in exhaust gas(2005-03-01) ;Tsai, CJ ;Lin, CH ;Wang, YM ;Hunag, CHLi, SNAn efficient venturi scrubber system making use of heterogeneous nucleation and condensational growth of particles was designed and tested to remove fine particles from the exhaust of a local scrubber where residual SiH4 gas was abated and lots of fine SiO2 particles were generated. In front of the venturi scrubber, normal-temperature fine-water mist mixes with high-temperature exhaust gas to cool it to the saturation temperature, allowing submicron particles to grow into micron sizes. The grown particles are then scrubbed efficiently in the venturi scrubber. Test results show that the present venturi scrubber system is effective for removing submicron particles. For SiO2 particles greater than 0.1 mum, the removal efficiency is greater than 80-90%, depending on particle concentration. The corresponding pressure drop is relatively low. For example, the pressure drop of the venturi scrubber is similar to15.4 +/- 2.4 cm H2O when the liquid-to-gas ratio is 1.50 L/m(3). A theoretical calculation has been conducted to simulate particle growth process and the removal efficiency of the venturi scrubber. The theoretical results agree with the experimental data reasonably well when SiO2 particle diameter is greater than 0.1 mum.Item type:Item, The effect of environmental conditions and electrical charge on the weighing accuracy of different filter materials(2002-07-03) ;Tsai, CJ ;Chang, CT ;Shih, BH ;Aggarwal, SGLi, SNDifferent filter materials and electrical charge elimination methods were used to investigate the weighing accuracy of filter papers under different environmental conditions. The results show that the standard deviations (S.D.) of weight data for glass fiber and MCE filters were substantial without environmental control, whether or not the electrical charge eliminators were used. Values of 0.157 and 0.349 mg were determined for glass and NICE filters, respectively. The accuracy of weighing was substantially improved and the S.D. was reduced to 0.01 and 0.09 mg for glass fiber and MCE filters, respectively, after applying the environmental control conditions. For PVC and Teflon filters, the accuracy of weighing was good, even in the uncontrolled environmental conditions, whether or not the electrical charge eliminators were used. The S.D. values of weighing data of PVC and Teflon filters were 0.007 and 0.011 mg, respectively. (C) 2002 Elsevier Science B.V. All rights reserved.