Item type:Item, Biomechanical comparison of three stand-alone lumbar cages - a three-dimensional finite element analysis(2013-10-02) ;Chen, Shih-Hao ;Chiang, Ming-Chieh ;Lin, Jin-Fu ;Lin, Shang-ChihHung, Ching-HuaBackground: For anterior lumbar interbody fusion (ALIF), stand-alone cages can be supplemented with vertebral plate, locking screws, or threaded cylinder to avoid the use of posterior fixation. Intuitively, the plate, screw, and cylinder aim to be embedded into the vertebral bodies to effectively immobilize the cage itself. The kinematic and mechanical effects of these integrated components on the lumbar construct have not been extensively studied. A nonlinearly lumbar finite-element model was developed and validated to investigate the biomechanical differences between three stand-alone (Latero, SynFix, and Stabilis) and SynCage-Open plus transpedicular fixation. All four cages were instrumented at the L3-4 level. Methods: The lumbar models were subjected to the follower load along the lumbar column and the moment at the lumbar top to produce flexion (FL), extension (EX), left/right lateral bending (LLB, RLB), and left/right axial rotation (LAR, RAR). A 10 Nm moment was applied to obtain the six physiological motions in all models. The comparison indices included disc range of motion (ROM), facet contact force, and stresses of the annulus and implants. Results: At the surgical level, the SynCage-open model supplemented with transpedicular fixation decreased ROM (>76%) greatly; while the SynFix model decreased ROM 56-72%, the Latero model decreased ROM 36-91%, in all motions as compared with the INT model. However, the Stabilis model decreased ROM slightly in extension (11%), lateral bending (21%), and axial rotation (34%). At the adjacent levels, there were no obvious differences in ROM and annulus stress among all instrumented models. Conclusions: ALIF instrumentation with the Latero or SynFix cage provides an acceptable stability for clinical use without the requirement of additional posterior fixation. However, the Stabilis cage is not favored in extension and lateral bending because of insufficient stabilization.Item type:Item, Biomechanical comparison of unilateral and bilateral pedicle screws fixation for transforaminal lumbar interbody fusion after decompressive surgery - a finite element analysis(2012-05-16) ;Chen, Shih-Hao ;Lin, Shang-Chih ;Tsai, Wen-Chi ;Wang, Chih-WeiChao, Shih-HengBackground: Little is known about the biomechanical effectiveness of transforaminal lumbar interbody fusion (TLIF) cages in different positioning and various posterior implants used after decompressive surgery. The use of the various implants will induce the kinematic and mechanical changes in range of motion (ROM) and stresses at the surgical and adjacent segments. Unilateral pedicle screw with or without supplementary facet screw fixation in the minimally invasive TLIF procedure has not been ascertained to provide adequate stability without the need to expose on the contralateral side. This study used finite element (FE) models to investigate biomechanical differences in ROM and stress on the neighboring structures after TLIF cages insertion in conjunction with posterior fixation. Methods: A validated finite-element (FE) model of L1-S1 was established to implant three types of cages (TLIF with a single moon-shaped cage in the anterior or middle portion of vertebral bodies, and TLIF with a left diagonally placed ogival-shaped cage) from the left L4-5 level after unilateral decompressive surgery. Further, the effects of unilateral versus bilateral pedicle screw fixation (UPSF vs. BPSF) in each TLIF cage model was compared to analyze parameters, including stresses and ROM on the neighboring annulus, cage-vertebral interface and pedicle screws. Results: All the TLIF cages positioned with BPSF showed similar ROM (<5%) at surgical and adjacent levels, except TLIF with an anterior cage in flexion (61% lower) and TLIF with a left diagonal cage in left lateral bending (33% lower) at surgical level. On the other hand, the TLIF cage models with left UPSF showed varying changes of ROM and annulus stress in extension, right lateral bending and right axial rotation at surgical level. In particular, the TLIF model with a diagonal cage, UPSF, and contralateral facet screw fixation stabilize segmental motion of the surgical level mostly in extension and contralaterally axial rotation. Prominent stress shielded to the contralateral annulus, cage-vertebral interface, and pedicle screw at surgical level. A supplementary facet screw fixation shared stresses around the neighboring tissues and revealed similar ROM and stress patterns to those models with BPSF. Conclusions: TLIF surgery is not favored for asymmetrical positioning of a diagonal cage and UPSF used in contralateral axial rotation or lateral bending. Supplementation of a contralateral facet screw is recommended for the TLIF construct.Item type:Item, Droplet manipulation by electrowetting on polymer dispersed liquid crystal(2007) ;Chiu, Cheng-Pu ;Lin, Shang-Chih ;Fan, Shih-Kang ;材料科學與工程學系奈米科技碩博班Graduate Program of Nanotechnology , Department of Materials Science and EngineeringDroplets were successfully manipulated on an electrowetting-on-dielectric (EWOD) device whose dielectric layer was a polymer dispersed liquid crystal (PDLC) thin film. Dielectric layer is essential to EWOD since it would store charges and change the surface wettability. Therefore, most of the research on the dielectric material was focused on its dielectric constant and strength. However, besides serving as only a capacitor, many dielectric materials possess other physical or chemical characteristics including optical, thermal, and mechanical properties. In this paper, we introduced and investigated electrowetting on an electro-optic material PDLC. By applying a voltage across the PDLC film, dual phenomena, EWOD and electro-optic effects, were achieved. The proposed droplet manipulating device would be beneficial when light regulation is necessary.Item type:Item, Finite element comparison of retrograde intramedullary nailing and locking plate fixation with/without an intramedullary allograft for distal femur fracture following total knee arthroplasty(2014-01-01) ;Chen, Shih-Hao ;Chiang, Ming-Chieh ;Hung, Ching-Hua ;Lin, Shang-ChihChang, Hsiao-WeiPurpose: Periprosthetic distal femur fracture after total knee arthroplasty due to the stress-shielding phenomenon is a challenging problem. Retrograde intramedullary nail (RIMN) or locking plate (LP) fixation with/without a strut allograft has been clinically used via less invasive stabilization surgery (LISS) for the treatment of these periprosthetic fractures. However, their biomechanical differences in construct stability and implant stress have not been extensively studied, especially for the osteoporotic femur. Methods: This study used a finite-element method to evaluate the differences between RIMN, LP, and LP/allograft fixation in treating periprosthetic distal femur fractures. There were sixteen variations of two fracture angles (transverse and oblique), two loading conditions (compression and rotation), and four bony conditions (one normal and three osteoporotic). Construct stiffness, fracture micromotion, and implant stress were chosen as the comparison indices. Results: The LP/allograft construct provides both lateral and middle supports to the displaced femur. Comparatively, the LP and RIMN constructs, respectively, transmit the loads through the lateral and middle paths, thus providing more unstable support to the construct and high stressing on the implants. The fracture pattern plays a minor role in the construct stabilization of the three implants. In general, the biomechanical performances of the RIMN and LP constructs were comparable and significantly inferior to those of the LP/allograft construct. The bone quality should be evaluated prior to the selection of internal fixators. Conclusions: The LP/allograft construct significantly stabilizes the fracture gap, reduces the implant stress, and serves as the recommended fixation for periprosthetic distal femur fracture. (C) 2013 Elsevier B.V. All rights reserved.Item type:Item, Metalworking Industry: Quality Management via Edge Computing-based Cloud Monitoring System(2019-01-01) ;Wu, Zheng-Wei ;Lin, Shang-Chih ;Hu, Po-Chun ;Su, Shun-FengHuang, YennunThis study uses the edge computing system for fast quality screening in the metal processing industry, and the Internet of Things technology is responsible for delivering data to the cloud for visualization and analysis. First, the system consists of optical components and embedded systems. Further, a fast Fourier transform is used to make the image have frequency characteristics. However, the convolution operation between the random kernel model and the image is the main means of feature extraction. In order to evaluate the performance and convergence of the proposed method, a rapid screening mechanism for good/bad products is defined. Finally, the data is passed to the cloud (ThingSpeak) platform for visualization through the MQTT protocol, and the content is subscribed to the content by the background host to perform the quality decision of the fuzzy inference system. The result is released back to the cloud. The experimental results in the industrial example show that the proposed method can accurately and quickly complete the quality inspection of surface roughness, and the feature distribution is easy to understand. At the same time, the edge computing system has the advantages of instant response and low cost, while the Internet of Things technology brings more management and analysis convenience. In future research, the unsupervised learning algorithm based on convolutional neural networks is a potential application, which can learn the quality of good or bad through a large amount of data.Item type:Item, Pretension Effects of the Dynesys Cord on the Tissue Responses and Screw-Spacer Behaviors of the Lumbosacral Construct With Hybrid Fixation(2013-06-01) ;Chien, Chen-Ying ;Tan, Ching-Hong ;Lu, Tsai-Hsiung ;Lin, Shang-ChihChuang, Wen-HsienStudy Design. The pretension of the Dynesys cord was varied to evaluate its effects on both tissue responses and screw-spacer behaviors by the finite-element method. Objective. This study aimed to provide detailed information about the motion-preserving and load-shielding mechanisms of the Dynesys screw-spacer joint. Summary of Background Data. Intuitively, higher cord pretension aims to ensure the occurrence of screw-spacer contact, thus making the spacer the transmitter of the vertebral loads. However, detailed investigations of the cord-pretension effects have not yet been carried out. Methods. Using a validated lumbosacral model, the moderately degenerative L4-L5 segment was instrumented by a static fixator and the Dynesys fixator was further used to bridge a mildly degenerative L3-L4 segment. The pre-tended cord was modeled as an elastic spring with 0- and 300-N pretensions. The disc range-of-motion, disc stress, facet force, bone-screw stress, and screw-spacer force were chosen as comparison indices. Results. At the transition and adjacent segments, the range-ofmotion differences between the 2 pretensions were 7.7% and 2.0% on average, respectively. The mechanical differences at the transition and adjacent segments were 9.0% and 5.2% (disc stress) and 9.4% and 9.1% (facet force), respectively. The results indicated that the cord pretension has a minor effect on the adjacent segments in comparison with the transition segment. However, the stress at the screw hub and force of the screw-spacer contact of the 300-N pretension were increased by 33.7% and 316.5% on average than without pretension, respectively. Conclusion. The moment arm from the screw-cord center to the fulcrum is signifi cantly less than that of vertebral loads. This leads to the minor effect of increasing the cord pretension on the responses of the adjacent segments. However, the cord pretension can signifi cantly affect both screw-spacer force and bone-screw stress.