Browsing by Author "Lin, Yu-Chao"
Now showing 1 - 4 of 4
- Results Per Page
- Sort Options
Item type:Item, Conversion of absorption to fluorescence probe in solid-state sensor for nitric oxide and nitrite(2013-04-01) ;Hong, Wun-Yan ;Yang, Tsung-Wei ;Wang, Chun-Ming ;Syu, Jia-HaoLin, Yu-ChaoA hydrogel bi-layer structure is used to convert an absorption type to a more convenient fluorescent type probe film for aqueous nitric oxide (NO) and nitrite (NO2-). In the bottom layer the commercial probe molecule 1,2-diaminoanthraquinone (DAQ) is dispersed in poly 2-hydroxyethyl methacrylate (poly HEMA), in the top layer the red inorganic phosphor is dispersed in poly HEMA. Both optical excitation and detection is from the bottom. This bi-layer is integrated with organic light-emitting diode (OLED) and organic photo-detector to form a real-time solid-state sensor. The sensor is responsive to NO bubbling, and remains stable in acid condition. Crown Copyright (C) 2012 Published by Elsevier B.V. All rights reserved.Item type:Item, Electrospun Fibers as a Solid-State Real-Time Zinc Ion Sensor with High Sensitivity and Cell Medium Compatibility(2013-03-25) ;Syu, Jia-Hao ;Cheng, Yi-Kai ;Hong, Wun-Yan ;Wang, Hsing-PingLin, Yu-Chaomeso-2,6-Dichlorophenyltripyrrinone (TPN-Cl2), a probe molecule for zinc II ions, is dispersed in a polymer host. The red fluorescence peak at 620 nm appears when the molecule forms a complex with zinc at its center. TPN-Cl2 has a high selectivity for zinc II and tolerates many common metal ions present in the human body. The probe molecules are blended with a hydrogel polymer, poly(2-hydroxyethyl methacrylate) (poly HEMA), with 30 wt% dimethylformamide (DMF). The fiber structure with 1 m diameter is made by electrospinning in DMF solution of the probe and poly HEMA mixture. The fibrous film detects zinc ions with concentrations as low as 106 M in real-time both in water and in the commonly used cell culture liquid media Dulbecco's modified Eagle medium (DMEM) and fetal bovine serum (FBS), which contain many metal ions and proteins. The time-resolution is 5 min for 106 M and 1 min for 105 M. This sensitivity and response speed satisfy the requirements for non-invasive biomedical studies.Item type:Item, Solid-state sensing tip for zinc ion with double parallel optical fibers embedded in fluorescent hydrogel(2015-11-01) ;Su, Heng-Tsan ;Tsai, May-Jywan ;Chang, Gao-Fong ;Hung, Chen-HsiungLin, Hung-ChengA tip-shaped zinc ion solid-state sensor is made by two parallel optical fibers embedded closely in a sensing hydrogel film. The film is made of poly(2-hydroxyethyl methacrylate) (poly HEMA) hydrogel mixed with the selective fluorescent probe meso-2,6-Dichlorophenyltripyrrinone (TPN-Cl-2) with weight ratio of 0.025 wt%. A 405 nm laser output is sent from one fiber and the 622 nm fluorescence of the doped hydrogel is collected by the second fiber. Each fiber diameter is 370 mu m (core is 300 mu m), whose sum is roughly the tip diameter. The 0.4 cm by 0.5 cm tip has real-time response for zinc ion concentration over 10(-6) M, with marginal signal for 10(-7) M. The tip is inserted inside an oyster and successfully detects the zinc ions, showing that the sensor works in complex body fluid and tolerates certain mechanical stress. To show the potential application for medicine, the sensing film is applied for primary neuronal cultures. We report for the first time zinc ions release at concentration levels 10(-6)-10(-7) M to the medium under stress conditions of ischemia, inflammation, and intoxication. Furthermore, this correlates with the zinc levels detected by biochemical assay. Such sensing tip has great potential for biomedical monitoring ex vivo or in vivo. (C) 2015 Elsevier B.V. All rights reserved.Item type:Item, Solid-state sensing tip for zinc ion with double parallel optical fibers embedded in fluorescent hydrogel (vol 26, pg 429, 2015)(2016-08) ;Su, Heng-Tsan ;Tsai, May-Jywan ;Chang, Gao-Fong ;Hung, Chen-HsiungLin, Hung-Cheng