Browsing by Author "Lin, Yuan-Pin"
Now showing 1 - 8 of 8
- Results Per Page
- Sort Options
Item type:Item, Augmenting VR/AR Applications with EEG/EOG Monitoring and Oculo-Vestibular Recoupling(2016-01-01) ;Zao, John K. ;Jung, Tzyy-Ping ;Chang, Hung-Ming ;Gan, Tchin-TzeWang, Yu-TeHead-mounted virtual reality and augmented reality displays (a. k. a. VR/AR goggles) created a revolutionary multimedia genre that is seeking ever-broadening applications and novel natural human interfaces. Adding neuromonitoring and neurofeedback to this genre is expected to introduce a new dimension to user interaction with the cyber-world. This study presents the development of a Neuromonitoring VR/AR Goggle armed with electroencephalo- gram and electrooculogram sensors, programmable milli-Ampere current stimulators and wireless fog/cloud computing support. Beside of its potential use in mitigating cybersickness, this device may have potential applications in augmented cognition ranging from feedback-controlled perceptual training to on-line learning and virtual social interactions. A prototype of the device has been made from a Samsung Gear VR for S6. This study explains its technical design to ensure precision data sampling, synchronous event marking, real-time signal processing and big data cloud computing support. This study also demonstrates the effective-ness in measuring the event-related potentials during a visual oddball experiment.Item type:Item, Automatic Design for Independent Component Analysis based Brain-computer Interfacing(2013) ;Chuang, Chun-Hsiang ;Lin, Yuan-Pin ;Ko, Li-Wei ;Jung, Tzyy-PingLin, Chin-TengThis study proposes a new framework, independent component ensemble, to leverage the acquired knowledge into a truly automatic and on-line EEG-based brain-computer interfacing (BCI). The envisioned design includes: (1) independent source recover using independent component analysis (ICA) (2) automatic selection of the independent components of interest (ICi) associated with human behaviors; (3) multiple classifiers with a parallel constructing and processing structure; and (4) a simple fusion scheme to combine the decisions from multiple classifiers. Its implications in BCI are demonstrated through a sample application: cognitive-state monitoring of participants performing a realistic sustained-attention driving task. Empirical results showed the proposed ensemble design could provide an improvement of 7%similar to 15% in overall accuracy for the classification of the arousal state and the driving performance. In summary, constructing ICi-ensemble classifiers and combining their outputs demonstrates a practical option for ICA-based BCIs to reduce the risk of not obtaining any desired independent source or selecting an inadequate component. Most importantly, the ensemble design for integrating information across multiple brain areas creates potentials for developing more complicated BCIs for real world applications.Item type:Item, Co-modulatory spectral changes in independent brain processes are correlated with task performance(2012-09-01) ;Chuang, Shang-Wen ;Ko, Li-Wei ;Lin, Yuan-Pin ;Huang, Ruey-SongJung, Tzyy-Ping"This study investigates the independent modulators that mediate the power spectra of electrophysiological processes, measured by electroencephalogram (EEG), in a sustained-attention experiment. EEG and behavioral data were collected during 1-2 hour virtual-reality based driving experiments in which subjects were instructed to maintain their cruising position and compensate for randomly induced drift using the steering wheel. Independent component analysis (ICA) applied to 30-channel EEG data separated the recorded EEG signals into a sum of maximally temporally independent components (ICs) for each of 30 subjects. Logarithmic spectra of resultant IC activities were then decomposed by principal component analysis, followed by ICA, to find spectrally fixed and temporally independent modulators (IM). Across subjects, the spectral ICA consistently found four performance-related independent modulators: delta, delta-theta, alpha, and beta modulators that multiplicatively affected the spectra of spatially distinct IC processes when the participants experienced waves of alternating alertness and drowsiness during long-hour simulated driving. The activation of the delta-theta modulator increased monotonically as subjects' task performances decreased. Furthermore, the time courses of the theta-beta modulator were highly correlated with concurrent changes in driving errors across subjects (r = 0.77 +/- 0.13). (c) 2012 Elsevier Inc. All rights reserved."Item type:Item, Detecting Glaucoma With a Portable Brain-Computer Interface for Objective Assessment of Visual Function Loss(2017-06-01) ;Nakanishi, Masaki ;Wang, Yu-Te ;Jung, Tzyy-Ping ;Zao, John K.Chien, Yu-YiIMPORTANCE The current assessment of visual field loss in diseases such as glaucoma is affected by the subjectivity of patient responses and the lack of portability of standard perimeters. OBJECTIVE To describe the development and initial validation of a portable brain-computer interface (BCI) for objectively assessing visual function loss. DESIGN, SETTING, AND PARTICIPANTS This case-control study involved 62 eyes of 33 patients with glaucoma and 30 eyes of 17 healthy participants. Glaucoma was diagnosed based on a masked grading of optic disc stereophotographs. All participants underwent testing with a BCI device and standard automated perimetry (SAP) within 3 months. The BCI device integrates wearable, wireless, dry electroencephalogram and electrooculogram systems and a cellphone-based head-mounted display to enable the detection of multifocal steady state visual-evoked potentials associated with visual field stimulation. The performances of global and sectoral multifocal steady state visual-evoked potentials metrics to discriminate glaucomatous from healthy eyes were compared with global and sectoral SAP parameters. The repeatability of the BCI device measurements was assessed by collecting results of repeated testing in 20 eyes of 10 participants with glaucoma for 3 sessions of measurements separated by weekly intervals. MAIN OUTCOMES AND MEASURES Receiver operating characteristic curves summarizing diagnostic accuracy. Intraclass correlation coefficients and coefficients of variation for assessing repeatability. RESULTS Among the 33 participants with glaucoma, 19 (58%) were white, 12 (36%) were black, and 2 (6%) were Asian, while among the 17 participants with healthy eyes, 9 (53%) were white, 8 (47%) were black, and none were Asian. The receiver operating characteristic curve area for the global BCI multifocal steady state visual-evoked potentials parameter was 0.92 (95% CI, 0.86-0.96), which was larger than for SAP mean deviation (area under the curve, 0.81; 95% CI, 0.72-0.90), SAP mean sensitivity (area under the curve, 0.80; 95% CI, 0.69-0.88; P = .03), and SAP pattern standard deviation (area under the curve, 0.77; 95% CI, 0.66-0.87; P = .01). No statistically significant differences were seen for the sectoral measurements between the BCI and SAP. Intraclass coefficients for global and sectoral parameters ranged from 0.74 to 0.92, and mean coefficients of variation ranged from 3.03% to 7.45%. CONCLUSIONS AND RELEVANCE The BCI device may be useful for assessing the electrical brain responses associated with visual field stimulation. The device discriminated eyes with glaucomatous neuropathy from healthy eyes in a clinically based setting. Further studies should investigate the feasibility of the BCI device for home-based testing as well as for detecting visual function loss over time.Item type:Item, Generalizations of the Subject-independent Feature Set for Music-induced Emotion Recognition(2011) ;Lin, Yuan-Pin ;Chen, Jyh-Horng ;Duann, Jeng-Ren ;Lin, Chin-TengJung, Tzyy-PingElectroencephalogram (EEG)-based emotion recognition has been an intensely growing field. Yet, how to achieve acceptable accuracy on a practical system with as fewer electrodes as possible is less concerned. This study evaluates a set of subject-independent features, based on differential power asymmetry of symmetric electrode pairs [1], with emphasis on its applicability to subject variability in music-induced emotion classification problem. Results of this study have evidently validated the feasibility of using subject-independent EEG features to classify four emotional states with acceptable accuracy in second-scale temporal resolution. These features could be generalized across subjects to detect emotion induced by music excerpts not limited to the music database that was used to derive the emotion-specific features.Item type:Item, Independent Component Ensemble of EEG for Brain-Computer Interface(2014-03-01) ;Chuang, Chun-Hsiang ;Ko, Li-Wei ;Lin, Yuan-Pin ;Jung, Tzyy-PingLin, Chin-TengRecently, successful applications of independent component analysis (ICA) to electroencephalographic (EEG) signals have yielded tremendous insights into brain processes that underlie human cognition. Many studies have further established the feasibility of using independent processes to elucidate human cognitive states. However, various technical problems arise in the building of an online brain-computer interface (BCI). These include the lack of an automatic procedure for selecting independent components of interest (ICi) and the potential risk of not obtaining a desired ICi. Therefore, this study proposes an ICi-ensemble method that uses multiple classifiers with ICA processing to improve upon existing algorithms. The mechanisms that are used in this ensemble system include: 1) automatic ICi selection; 2) extraction of features of the resultant ICi; 3) the construction of parallel pipelines for effectively training multiple classifiers; and a 4) simple process that combines the multiple decisions. The proposed ICi-ensemble is demonstrated in a typical BCI application, which is the monitoring of participants\' cognitive states in a realistic sustained-attention driving task. The results reveal that the proposed ICi-ensemble outperformed the previous method using a single ICi with (91.6% versus 84.3%) in the cognitive state classification. Additionally, the proposed ICi-ensemble method that characterizes the EEG dynamics of multiple brain areas favors the application of BCI in natural environments.Item type:Item, Selective Transfer Learning for EEG-Based Drowsiness Detection(2015-01-01) ;Wei, Chun-Shu ;Lin, Yuan-Pin ;Wang, Yu-Te ;Jung, Tzyy-PingBigdely-Shamlo, NimaOn the pathway from laboratory settings to real world environment, a major challenge on the development of a robust electroencephalogram (EEG)-based brain-computer interface (BCI) is to collect a significant amount of informative training data from each individual, which is labor intensive and time-consuming and thereby significantly hinders the applications of BCIs in real-world settings. A possible remedy for this problem is to leverage existing data from other subjects. However, substantial inter-subject variability of human EEG data could deteriorate more than improve the BCI performance. This study proposes a new transfer learning (TL)-based method that exploits a subject\'s pilot data to select auxiliary data from other subjects to enhance the performance of an EEG-based BCI for drowsiness detection. This method is based on our previous findings that the EEG correlates of drowsiness were stable within individuals across sessions and an individual\'s pilot data could be used as calibration/training data to build a robust drowsiness detector. Empirical results of this study suggested that the feasibility of leveraging existing BCI models built by other subjects\' data and a relatively small amount of subject-specific pilot data to develop a BCI that can outperform the BCI based solely on the pilot data of the subject.Item type:Item, Transfer Learning with Large-Scale Data in Brain-Computer Interfaces(2016-01-01) ;Wei, Chun-Shu ;Lin, Yuan-Pin ;Wang, Yu-Te ;Lin, Chin-TengJung, Tzyy-PingHuman variability in electroencephalogram (EEG) poses significant challenges for developing practical real-world applications of brain-computer interfaces (BCIs). The intuitive solution of collecting sufficient user-specific training/calibration data can be very labor-intensive and time-consuming, hindering the practicability of BCIs. To address this problem, transfer learning (TL), which leverages existing data from other sessions or subjects, has recently been adopted by the BCI community to build a BCI for a new user with limited calibration data. However, current TL approaches still require training/calibration data from each of conditions, which might be difficult or expensive to obtain. This study proposed a novel TL framework that could nearly eliminate requirement of subject-specific calibration data by leveraging large-scale data from other subjects. The efficacy of this method was validated in a passive BCI that was designed to detect neurocognitive lapses during driving. With the help of large-scale data, the proposed TL approach outperformed the within-subject approach while considerably reducing the amount of calibration data required for each individual (similar to 1.5 min of data from each individual as opposed to a 90 min pilot session used in a standard within-subject approach). This demonstration might considerably facilitate the real-world applications of BCIs.