Browsing by Author "Liu, Tsan-Chi"
Now showing 1 - 3 of 3
- Results Per Page
- Sort Options
Item type:Item, Brain structure and spatial sensitivity profile assessing by near-infrared spectroscopy modeling based on 3D MRI data(2013-03-01) ;Chuang, Ching-Cheng ;Chen, Chung-Ming ;Hsieh, Yao-Sheng ;Liu, Tsan-ChiSun, Chia-WeiThe goal of this study is to prove that the light propagation in the head by used the 3-D optical model from in vivo MRI data set can also provide significant characteristics on the spatial sensitivity of cerebral cortex folding geometry based on Monte Carlo simulation. Thus, we proposed a MRI based approach for 3-D brain modeling of near-infrared spectroscopy (NIRS). In the results, the spatial sensitivity profile of the cerebral cortex folding geometry and the arrangement of source-detector separation have being necessarily considered for applications of functional NIRS. The optimal choice of source-detector separation is suggested within 33.5 cm by the received intensity with different source-detector separations and the ratio of received light from the gray and white matter layer is greater than 50%. Additionally, this study has demonstrated the capability of NIRS in not only assessing the functional but also detecting the structural change of the brain by taking advantage of the low scattering and absorption coefficients observed in CSF of sagittal view. ((c) 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim)Item type:Item, Diffuser-Aided Diffuse Optical Imaging for Breast Tumor: A Feasibility Study Based on Time-Resolved Three-Dimensional Monte Carlo Modeling(2012-05-01) ;Chuang, Ching-Cheng ;Lee, Chia-Yen ;Chen, Chung-Ming ;Hsieh, Yao-ShengLiu, Tsan-ChiThis study proposed diffuser-aided diffuse optical imaging (DADOI) as a new approach to improve the performance of the conventional diffuse optical tomography (DOT) approach for breast imaging. The 3-D breast model for Monte Carlo simulation is remodeled from clinical MRI image. The modified Beer-Lambert's law is adopted with the DADOI approach to substitute the complex algorithms of inverse problem for mapping of spatial distribution, and the depth information is obtained based on the time-of-flight estimation. The simulation results demonstrate that the time-resolved Monte Carlo method can be capable of performing source-detector separations analysis. The dynamics of photon migration with various source-detector separations are analyzed for the characterization of breast tissue and estimation of optode arrangement. The source-detector separations should be less than 4 cm for breast imaging in DOT system. Meanwhile, the feasibility of DADOI was manifested in this study. In the results, DADOI approach can provide better imaging contrast and faster imaging than conventional DOT measurement. The DADOI approach possesses great potential to detect the breast tumor in early stage and chemotherapy monitoring that implies a good feasibility for clinical application.Item type:Item, Patient-oriented simulation based on Monte Carlo algorithm by using MRI data(2012-04-17) ;Chuang, Ching-Cheng ;Lee, Yu-Tzu ;Chen, Chung-Ming ;Hsieh, Yao-ShengLiu, Tsan-ChiBackground: Although Monte Carlo simulations of light propagation in full segmented three-dimensional MRI based anatomical models of the human head have been reported in many articles. To our knowledge, there is no patient-oriented simulation for individualized calibration with NIRS measurement. Thus, we offer an approach for brain modeling based on image segmentation process with in vivo MRI T1 three-dimensional image to investigate the individualized calibration for NIRS measurement with Monte Carlo simulation. Methods: In this study, an individualized brain is modeled based on in vivo MRI 3D image as five layers structure. The behavior of photon migration was studied for this individualized brain detections based on three-dimensional time-resolved Monte Carlo algorithm. During the Monte Carlo iteration, all photon paths were traced with various source-detector separations for characterization of brain structure to provide helpful information for individualized design of NIRS system. Results: Our results indicate that the patient-oriented simulation can provide significant characteristics on the optimal choice of source-detector separation within 3.3 cm of individualized design in this case. Significant distortions were observed around the cerebral cortex folding. The spatial sensitivity profile penetrated deeper to the brain in the case of expanded CSF. This finding suggests that the optical method may provide not only functional signal from brain activation but also structural information of brain atrophy with the expanded CSF layer. The proposed modeling method also provides multi-wavelength for NIRS simulation to approach the practical NIRS measurement. Conclusions: In this study, the three-dimensional time-resolved brain modeling method approaches the realistic human brain that provides useful information for NIRS systematic design and calibration for individualized case with prior MRI data.