Browsing by Author "Liu, Yu-Hang"
Now showing 1 - 2 of 2
- Results Per Page
- Sort Options
Item type:Item, Novel Dry Polymer Foam Electrodes for Long-Term EEG Measurement(2011-05-01) ;Lin, Chin-Teng ;Liao, Lun-De ;Liu, Yu-Hang ;Wang, I-JanLin, Bor-ShyhA novel dry foam-based electrode for long-term EEG measurement was proposed in this study. In general, the conventional wet electrodes are most frequently used for EEG measurement. However, they require skin preparation and conduction gels to reduce the skin-electrode contact impedance. The aforementioned procedures when wet electrodes were used usually make trouble to users easily. In order to overcome the aforesaid issues, a novel dry foam electrode, fabricated by electrically conductive polymer foam covered by a conductive fabric, was proposed. By using conductive fabric, which provides partly polarizable electric characteristic, our dry foam electrode exhibits both polarization and conductivity, and can be used to measure biopotentials without skin preparation and conduction gel. In addition, the foam substrate of our dry electrode allows a high geometric conformity between the electrode and irregular scalp surface to maintain low skin-electrode interface impedance, even under motion. The experimental results presented that the dry foam electrode performs better for long-term EEG measurement, and is practicable for daily life applications.Item type:Item, Performance Optimized of the Novel Dry EEG Electrodes by using the Non-Dominated Sorting Genetic Algorithms (NSGA-II)(2010) ;Han, Ming-Feng ;Liao, Lun-De ;Liu, Yu-Hang ;Wang, Wan-RuLin, Bor-ShyhIn this study, a optimization process was performed for the developed dry electroencephalography (EEG) electrodes by using the Non-dominated Sorting Genetic Algorithm II (NSGA-II) to minima the skin-electrode impedance. The developed dry EEG electrodes can measure the EEG signals without any gels applied and no skin preparation. However, how to find a proper skin-electrode contact area is an important issue. The contact area is directly related to the electrodes impedance and fabrication cost. Therefore, the NSGA-II is used to searching the suitable contact area and other design parameters. NSGA-II is a wieldy used optimization method, especially for the multi-objectives issues like this case. Finally, we compare the results of the simulation and experiments for ensuring the optimal process. The experiment results show that using the optimal values provided from NSGA-II can achieve the minima skin-electrode impedance. It confirms the dry electrode can be effectively used for the cognitive or other applications in the future.