Browsing by Author "Lu, C"
Now showing 1 - 2 of 2
- Results Per Page
- Sort Options
Item type:Item, Characteristics of MOCVD- and MBE-grown InGa(N)As VCSELs(2005-08-01) ;Yang, HPD ;Lu, C ;Hsiao, R ;Chiou, CLee, CWe report our results on InGaNAs/GaAs vertical-cavity surface-emitting lasers (VCSELs) in the 1.3 mu m range. The epitaxial structures were grown on (10 0) GaAs substrates by metalorganic chemical vapour deposition (MOCVD) or molecular beam epitaxy (MBE). The nitrogen composition of the InGa(N)As/GaAs quantum-well (QW) active region is 0-0.02. The long-wavelength (up to 1.3 mu m) room-temperature continuous-wave (RT CW) lasing operation was achieved for MBE- and MOCVD-grown VCSELs. For MOCVD-grown devices with n- and p-doped distributed Bragg reflectors (DBRs), a maximum optical output power of 0.74 mW was measured for In(0.36)Ga(0.64)N(0.006)AS(0.994)/GaAs VCSELs. A very low J(th) of 2.55 kA cm(-2) was obtained for the InGaNAs/GaAs VCSELs. The MBE-grown devices were made with an intracavity structure. Top-emitting multi-mode 1.3 mu m In0.35Ga0.65N0.02As0.98/GaAs VCSELs with 1 mW output power have been achieved under RT CW operation. A J(th) of 1.52 kA cm-2 has been obtained for the MBE-grown In0.35Ga0.65N0.02As0.98/GaAs VCSELs, which is the lowest threshold current density reported. The emission characteristics of the InGaNAs/GaAs VCSELs were measured and analysed.Item type:Item, Sources of sampling error for field measurement of nitric acid gas by a denuder system(2003-03-01) ;Bai, H ;Lu, C ;Chang, KF ;Fang, GC環境工程研究所Field measurements of atmospheric HNO3 gas by a denuder system equipped with four annular denuders were conducted in Taiwan. The positive errors from interfering N-compounds as well as the negative errors from incompleteness of the apparent absorption of the HNO3 gas. as sampled by one NaCl-denuder, were quantitatively determined and the error sources were identified. It is found that the concentrations of positive error and negative error might cancel each other resulting in less difference between the measured and the true HNO3 concentrations. The atmospheric HNO3 concentration and the ambient temperature were the major factors that influence the degree of negative errors. The apparent absorption efficiency might decrease to less than 80% if the HNO3 gas concentration were lower than 0.3 mug m(-3) or the ambient temperature were over 28degreesC. There are also evidences showed that the positive errors were from both interfering N-containing gases and nitrate-containing particles. (C) 2003 Elsevier Science Ltd. All rights reserved.