Browsing by Author "Miyazaki, J."
Now showing 1 - 2 of 2
- Results Per Page
- Sort Options
Item type:Item, Frequency domain approach for time-resolved pump-probe microscopy using intensity modulated laser diodes(2014-09-01) ;Miyazaki, J. ;Kawasumi, K. ;Kobayashi, T. ;電子物理學系Department of ElectrophysicsWe present a scheme for time-resolved pump-probe microscopy using intensity modulated laser diodes. The modulation frequencies of the pump and probe beams are varied up to 500 MHz with fixed frequency detuning typically set at 15 kHz. The frequency response of the pump-probe signal is detected using a lock-in amplifier referenced at the beat frequency. This frequency domain method is capable of characterizing the nanosecond to picosecond relaxation dynamics of sample species without the use of a high speed detector or a high frequency lock-in amplifier. Furthermore, as the pump-probe signal is based on the nonlinear interaction between the two laser beams and the sample, our scheme provides better spatial resolution than the conventional diffraction-limited optical microscopes. Time-resolved pump-probe imaging of fluorescence beads and aggregates of quantum dots demonstrates that this method is useful for the microscopic analysis of optoelectronic devices. The system is implemented using compact and low-cost laser diodes, and thus has a broad range of applications in the fields of photochemistry, optical physics, and biological imaging. (C) 2014 AIP Publishing LLC.Item type:Item, Resolution enhancement of pump-probe microscopy with an inverse-annular spatial filter(2016-12-01) ;Kobayashi, T. ;Kawasumi, K. ;Miyazaki, J. ;Nakata, K.電子物理學系We have introduced a pupil filter, an inverse-annular pupil filter in a pump-probe photothermal microscope, which provides resolution enhancement in three dimensions. The resolution is probed to be improved in lateral and axial resolution by imaging experiment using 20 nm gold nanoparticles. The improvement in X (perpendicular to the common pump and probe polarization direction), Y (parallel to the polarization direction), and Z (axial direction) are by 15 +/- 6, 8 +/- 8, and 21 +/- 2 % from the resolution without a pupil filter. The resolution enhancement is even better than the calculation using vector field, which predicts the corresponding enhancement of 11, 8, and 6 %. The discussion is made to explain the unexpected results. We also demonstrate the photothermal imaging of thick biological samples (cells from rabbit intestine and kidney) stained with hematoxylin and eosin dye with the inverse-annular filter. (C) 2016 Author(s).