Browsing by Author "Ni, CH"
Now showing 1 - 9 of 9
- Results Per Page
- Sort Options
Item type:Item, Application of a membrane bioreactor system for opto-electronic industrial wastewater treatment - a pilot study(2003) ;Chen, TK ;Chen, JN ;Ni, CH ;Lin, GTChang, CYThe membrane bioreactor (MBR) system has become more and more attractive in the field of wastewater treatment. It is particularly attractive in situations where long solids retention times are required, such as nitrifying bacteria, and physical retention is critical to achieving more efficiency for biological degradation of pollutants. Although it is a new technology, the MBR process has been applied to industrial wastewater treatment for only the past decade. The opto-electronic industry, developed very fast over the past decade in the world, is a high technological manufacturing industry. The treatment of the opto-electronic industrial wastewater containing a significant quantity of organic nitrogen compounds, with a ratio over 95% in organic nitrogen (Org-N) to total nitrogen (T-N), is very difficult to meet the discharge limits. The purpose of this research is mainly to discuss the treatment capacity of high-strength organic nitrogen wastewater, and to investigate the capabilities of the MBR process. A 2 m(3)/day capacity MBR pilot plant consisting of anoxic and aerobic tanks and a membrane bioreactor was installed for evaluation. The operation was continued for 130 days. Over the whole experimental period, a satisfactory organic removal performance was achieved. The COD could be removed with an average of over 94.5%. For TOC and BOD5, the average removal efficiencies were 96.3 and 97.6%, respectively. The nitrification and denitrification were also successfully achieved. The effluent did not contain any suspended solids. Only a small concentration of ammonia nitrogen was found in the effluent. The stable effluent quality and satisfactory removal performance mentioned above were ensured by the efficient interception performance of the membrane device incorporated within the biological reactor. The MBR system shows promise as a means of treating very high organic nitrogen wastewater without dilution. The effluent of TKN, NOx-N and COD can fall below 20 mg/L, 30 mg/L and 50 mg/L.Item type:Item, Biological nitrification and denitrification of opto-electronic industrial wastewater(2003) ;Chen, TK ;Ni, CH ;Chen, LN ;環境工程研究所Institute of Environmental EngineeringDevelopment and application of biological nutrient removal processes accelerated significantly over the past decade due to more stringent nutrients (nitrogen and phosphorus) discharge limits being imposed on wastewater treatment plants. The opto-electronic industry has developed very fast over the past decade in the world. The wastewater often contains a significant quantity of organic nitrogen compounds and has a ratio of over 95% in organic nitrogen (Org-N) to total nitrogen (T-N). In this study, a 2-stage Anoxic/Aerobic pre-denitrification process was established and the efficiency of wastewater treatment was evaluated. Wastewater from an actual LCD-plant was obtained as the sample for looking into the feasibility of opto-electronic industrial wastewater treatment. Hydraulic retention time (HRT) and mixed liquor recycle rate (MLR) were controlled independently to distinguish between the effects of these two factors. Under suitable HRT and mixed liquor recycle ratio, effluents of NH4-N, NOx-N and COD can fall below 20 mg/l, 30 mg/l and 80 mg/l.Item type:Item, Catalytic ozonation of 2-dichlorophenol by metallic ions(2003) ;Ni, CH ;Chen, JN ;Yang, PY ;環境工程研究所Institute of Environmental EngineeringThis research is mainly to explore functional improvement by adding various kinds of metallic ions in the ozonation of 2-chlorophenol solution. During the experiment, various kinds of metallic ions (Pb+, Cu2+, Zn2+, Fe2+, Ti2+, and Mn2+) were added; it was found that the reaction rate increased in all cases. The best result was obtained by using manganese ions, followed by iron and titanium ions. At pH = 3 and 1 ppm Mn2+ concentration, the reaction rate was increased by three times. TOC removal rate was also increased from 12.6% to 38% at 60 min reaction time. Ozone self-decomposition with various kinds of metallic ions alone was tested. It was found the ozone self-decomposition coefficient is highly dependent on the reaction rate constant for ozonation of 2-chlorophenol. The improvement of reaction was relevant to the mechanism of reaction between ozone and metallic ions. Furthermore, the effect of adding manganese ions was studied. With the initial manganese concentration at 0-2 ppm, after gas exposure for 20 min the removal rate can be increased from 38% to 93%. TOC removal rate was increased from 11% to 38%. The reaction rate was improved more greatly at the initial pH = 3.Item type:Item, Heterogeneous catalytic ozonation of 2-chlorophenol aqueous solution with alumina as a catalyst(2001) ;Ni, CH ;Chen, JN ;環境工程研究所Institute of Environmental EngineeringHeterogenous catalytic ozonation of 2-chlorophenol (2-CP) in the presence of gamma -alumina as a solid catalyst has been investigated in this research. It showed that the rate for degradation of TOC could increase from 21% to 43%. The pseudo-first reaction constants of 2-CP could increase from 0.8688 min(-1) to 0.1270, increasing by approximately 40%. At the same time, the consumption of ozone was only half that of ozone alone. This research also explored the effects of the catalyst dosage, pH values and removal kinetics of 2-CP. In addition, three consecutive running with the same catalyst revealed insignificant reduction of the activity. Furthermore, the elimination of toxicity was evaluated by Microtox(R) analysis. The detoxification was more stable and with good results.Item type:Item, High-strength nitrogen removal of opto-electronic industrial wastewater in membrane bioreactor - a pilot study(2003) ;Chen, TK ;Ni, CH ;Chen, JN ;Lin, J環境工程研究所The membrane bioreactor (MBR) system has become more and more attractive in the field of wastewater treatment. It is particularly attractive in situations where long solids retention times are required, such as nitrifying bacteria, and physical retention critical to achieving more efficiency for biological degradation of pollutant. Although it is a new technology, the MBR process has been applied for industrial wastewater treatment for only the past decade. The opto-electronic industry, developed very fast over the past decade in the world, is high technology manufacturing. The treatment of the opto-electronic industrial wastewater containing a significant quantity of organic nitrogen compounds with a ratio over 95% in organic nitrogen (Org-N) to total nitrogen (T-N) is very difficult to meet the discharge limits. This research is mainly to discuss the treatment capacity of high-strength organic nitrogen wastewater, and to investigate the capabilities of the MBR process. A 5 m(3)/day capacity of MBR pilot plant consisted of anoxic, aerobic and membrane bioreactor was installed for evaluation. The operation was continued for 150 days. Over the whole experimental period, a satisfactory organic removal performance was achieved. The COD could be removed with an average of over 94.5%. For TOC and BOD5 items, the average removal efficiencies were 96.3 and 97.6%, respectively. The nitrification and denitrification was also successfully achieved. Furthermore, the effluent did not contain any suspended solids. Only a small concentration of ammonia nitrogen was found in the effluent. The stable effluent quality and satisfactory removal performance mentioned above were ensured by the efficient interception performance of the membrane device incorporated within the biological reactor. The MBR system shows promise as a means of treating very high organic nitrogen wastewater without dilution. The effluent of TKN, NOx-N and COD can fall below 20 mg/L, 30 mg/L and 50 mg/L.Item type:Item, MBR/RO/ozone processes for TFT-LCD industrial wastewater treatment and recycling(2005) ;Chen, TK ;Ni, CH ;Chan, YC ;Lu, MC環境工程研究所This research is mainly to explore the treatment capacity for TFT-LCD industrial wastewater recycling by the processes combined with membrane bioreactor (MBR), reverse osmosis (RO) and ozone(03). The organic wastewater from the TFT-LCD industry was selected as the target. MBR, RO and ozone plants were established for evaluation. An MBR plant consisted of a 2-stage anoxic/aerobic bioreactor and an immersed UF membrane unit was employed. The effluent of MBR was conducted into the RO system then into the ozone system. The RO system consisted of a spiral membrane in the vessel. One bubble column, 75 cm high and diameter 5 cm, were used as the ozonation reactor. On the bottom of ozonation reactor is a porous diffuser for releasing gas, with an aperture of 100 mu m (0.1 cm). Over the whole experimental period, the MBR process achieved a satisfactory organic removal. The COD could be removed with an average of over 98.5%. For the TOC item, the average removal efficiency was 97.4%. The stable effluent quality and satisfactory removal performance were ensured by the efficient interception performance of an immersed UF membrane device incorporated with the biological reactor. Moreover, the MBR effluent did not contain any suspended solids and the SDI value was under 3. After the treatment of RO, excellent water quality was found. The water quality of permeate was under 5 mg/l, 2 mg/l and 50 mu s/cm for COD, TOC and conductivity respectively. The treated water can be recycled and reused for the cooling tower make-up water or other purposes. After the treatment of ozone, the treated water quality was under 5 mg/l and 0.852 mg/l for COD and TOC respectively. The test results of MBR, MBR/RO and MBR/RO/ozone processes were compared as possible appropriate treatment technologies applied in TFT-LCD industrial wastewater reuse and recycling.Item type:Item, Nitrification-denitrification of opto-electronic industrial wastewater by anoxic/aerobic process(2003) ;Chen, TK ;Ni, CH ;Chen, JN ;環境工程研究所Institute of Environmental EngineeringThis research focused on the biological treatment of high-strength organic nitrogen wastewater, and presented the results from the nitrification and denitrification of an actual industrial wastewater using anoxic/aerobic process, The opto-electronic industrial wastewater often contains a significant quantity of organic nitrogen compounds and has a ratio over 95% in organic nitrogen (Org-N) to total nitrogen (T-N). In this study, a 2-stage anoxic/aerobic process was established and evaluated the efficiency of wastewater treatment. Raw wastewater from an actual TFT-LCD manufacturing plant was obtained as the sample for looking into the feasibility of opto-electronic industrial wastewater treatment. After toxicity identification evaluation (TIE) test of raw wastewater, the inhibition was related to organic nitrogen (TMAH, MEA) and unionized ammonia (free ammonia, NH3) with high pH. Therefore, pH control is important for biological treatment of high-strength organic nitrogen industrial wastewater. Besides, hydraulic retention time (HRT) and mixed liquor recycled rate (MLR) were controlled independently to distinguish between the effects of these two factors. Under suitable HRT (> 1.7d) and mixed liquor recycled rate (< 4Q). effluent of Nh(4)-N, No-3-N+NO2-N, and COD can fall below 20mg/L, 30mg/L, and 80 mg/L. The anoxic/aerobic process removed 92-98% of the carbon source, and approximately 80% of TKN, 70% of T-N.Item type:Item, Ozonation of domestic secondary effluent for recycling and reuse - a pilot plant study(2002) ;Ni, CH ;Chen, JN ;Tsai, YC ;Chen, WBChen, CHIn this study, a pilot plant combined ozonation with sand filtration is established. Wastewater from the secondary effluent was taken as the sample for looking into the feasibility of domestic wastewater recovery and recycling. At the beginning, a series of hydraulic analysis and ozone transfer tests was conducted in the bubble column reactor. From these tests, it was found that when the gas flow is controlled to within 0.2similar to1.0 L/min and liquid flow within 0.5similar to2.5 L/min, using series connected mixing tank model for our calculation, the result J (CSTR) is 1similar to2. From the ozone transfer test it is known that the smaller the gas flow, the better the transfer rate, and the same pattern occurs on ozone gas concentration. After sand filtration and ozone treatment, the G/L ratio within the ozone column reactor can be maintained within 0.2similar to0.4 and the ozone dosage within 8similar to12 mg/L. The removal rate for coliform bacillus, BOD, turbidity and color is 99.96%, 62.2%, 89.6% and 67% respectively. After ozonation treatment, coliform bacillus content can be controlled under 10 CFU/mL, BOD under 10mg/L, turbidity within 2.0similar to2.5 (NTU), and color within 10.3similar to13.7 degree. The recycled water is almost colorless and odorless, and is capable of reaching the reference standard for recycled water.Item type:Item, Recycling and reuse of wastewater from a new-developed community using sand filtration, ultrafiltration, and ozonation(2003) ;Ni, CH ;Chen, JN ;Tsai, YC ;Chen, TKChen, WBIn this study, the pilot apparatus combined with sand filtration, ozonation and ultrafiltration was established. Wastewater from the secondary treatment effluent in the new-developed community was taken as the sample for looking into the feasibility of domestic wastewater reuse and recycling. The test results by sand filtration, sand filtration/ultrafiltration, sand filtration/ozonation, and sand filtration/ultrafiltration/ozonation were compared for looking for appropriate treatment processes applied in the domestic wastewater reuse and recycling, Finally, cost analysis was carried out and sand filtration/ozonation process was suggested to be one of the best processes. The total cost is about 0.1-0.32 $USD per cubic meter of produced water by considering the capital and operation cost for five years in the small domestic wastewater treatment plant (50-750 CMD).