Browsing by Author "Shih, Cheng-Min"
Now showing 1 - 5 of 5
- Results Per Page
- Sort Options
Item type:Item, Biomechanical analysis of acromioclavicular joint dislocation treated with clavicle hook plates in different lengths(2015-11-01) ;Shih, Cheng-Min ;Huang, Kui-Chou ;Pan, Chien-Chou ;Lee, Cheng-HungSu, Kuo-ChihClavicle hook plates are frequently used in clinical orthopaedics to treat acromioclavicular joint dislocation. However, patients often exhibit acromion osteolysis and per-implant fracture after undergoing hook plate fixation. With the intent of avoiding future complications or fixation failure after clavicle hook plate fixation, we used finite element analysis (FEA) to investigate the biomechanics of clavicle hook plates of different materials and sizes when used in treating acromioclavicular joint dislocation. Using finite element analysis, this study constructed a model comprising four parts: clavicle, acromion, clavicle hook plate and screws, and used the model to simulate implanting different types of clavicle hook plates in patients with acromioclavicular joint dislocation. Then, the biomechanics of stainless steel and titanium alloy clavicle hook plates containing either six or eight screw holes were investigated. The results indicated that using a longer clavicle hook plate decreased the stress value in the clavicle, and mitigated the force that clavicle hook plates exert on the acromion. Using a clavicle hook plate material characterized by a smaller Young\'s modulus caused a slight increase in the stress on the clavicle. However, the external force the material imposed on the acromion was less than the force exerted on the clavicle. The findings of this study can serve as a reference to help orthopaedic surgeons select clavicle hook plates.Item type:Item, Biomechanical Analysis of Implanted Clavicle Hook Plates With Different Implant Depths and Materials in the Acromioclavicular Joint: A Finite Element Analysis Study(2016-11) ;Lee, Cheng-Hung ;Shih, Cheng-Min ;Huang, Kui-Chou ;Chen, Kun-HuiHung, Li-KunClinical implantation of clavicle hook plates is often used as a treatment for acromioclavicular joint dislocation. However, it is not uncommon to find patients that have developed acromion osteolysis or had peri-implant fracture after hook plate fixation. With the aim of preventing complications or fixation failure caused by implantation of inappropriate clavicle hook plates, the present study investigated the biomechanics of clavicle hook plates made of different materials and with different hook depths in treating acromioclavicular joint dislocation, using finite element analysis (FEA). This study established four parts using computer models: the clavicle, acromion, clavicle hook plate, and screws, and these established models were used for FEA. Moreover, implantations of clavicle hook plates made of different materials (stainless steel and titanium alloy) and with different depths (12, 15, and 18mm) in patients with acromioclavicular joint dislocation were simulated in the biomechanical analysis. The results indicate that deeper implantation of the clavicle hook plate reduces stress on the clavicle, and also reduces the force applied to the acromion by the clavicle hook plate. Even though a clavicle hook plate made of titanium alloy (a material with a lower Young\'s modulus) reduces the force applied to the acromion by the clavicle hook plate, slightly higher stress on the clavicle may occur. The results obtained in this study provide a better reference for orthopedic surgeons in choosing different clavicle hook plates for surgery.Item type:Item, Comparison of implant failure rates of different plates for midshaft clavicular fractures based on fracture classifications(2019-07-16) ;Chiu, Yung-Cheng ;Huang, Kui-Chou ;Shih, Cheng-Min ;Lee, Kun-TsanChen, Kun-HuiBackgroundsThe aim of our study was to investigate failure rates of reconstruction plate and non-reconstruction plate, and find the best strategy for implant selection for different fracture types for midshaft clavicular fractures.Patients and methodsTwo hundred twenty-six consecutive patients with midshaft clavicular fractures who received open reduction and plate fixation during Jan 2012 to July 2017 were reviewed. The correlations between implant failure rates and risk factors including demographic data, fracture classifications, and implant types were analyzed.ResultsAO/OTA fracture classification and plate types are the most important factors affecting implant failure for midshaft clavicular fractures. Reconstruction plate had a significantly higher failure rate (53%) than that of non-reconstruction plates (3%) in comminuted midshaft clavicular (AO/OTA 15-2C) fractures (P value <0.01). However, the difference was not significant in AO/OTA 15-2A and 2B classifications.ConclusionPatients with comminuted midshaft clavicular (AO/OTA 15-2C) fractures treated with reconstruction plates had very high implant failure rates compared to non-reconstruction plates. We suggested that patients with comminuted midshaft clavicular (AO/OTA 15-2C) fractures treated with reconstruction plates need more protection and more frequent follow-up in the postoperative period.Item type:Item, Decision Support for the Optimization of Provider Staffing for Hospital Emergency Departments with a Queue-Based Approach(2019-12-01) ;Jiang, Fuu-Cheng ;Shih, Cheng-Min ;Wang, Yun-Ming ;Yang, Chao-TungChiang, Yi-JuDeployment or distribution of valuable medical resources has emerged as an increasing challenge to hospital administrators and health policy makers. The hospital emergency department (HED) census and workload can be highly variable. Improvement of emergency services is an important stage in the development of the healthcare system and research on the optimal deployment of medical resources appears to be an important issue for HED long-term management. HED performance, in terms of patient flow and available resources, can be studied using the queue-based approach. The kernel point of this research is to approach the optimal cost on logistics using queuing theory. To model the proposed approach for a qualitative profile, a generic HED system is mapped into the M/M/R/N queue-based model, which assumes an R-server queuing system with Poisson arrivals, exponentially distributed service times and a system capacity of N. A comprehensive quantitative mathematical analysis on the cost pattern was done, while relevant simulations were also conducted to validate the proposed optimization model. The design illustration is presented in this paper to demonstrate the application scenario in a HED platform. Hence, the proposed approach provides a feasibly cost-oriented decision support framework to adapt a HED management requirement.Item type:Item, Fracture of cobalt chrome, fully-coat beaded femoral revision long stem, a clinical outcomes study(2018-02-01) ;Chang, Chih-Hsiang ;Lin, Po-Chun ;Shih, Cheng-Min ;Chen, Chun-ChiehHsieh, Pang-HsinBackground: Femoral bone loss during revision total hip arthroplasty poses a challenging problem. Bypass fixation over the diaphysis has achieved clinical success in cases of proximal femoral bone loss. Fracture of cementless, fully bead-coated femoral stem is an uncommon complication. The purpose of this study is to analyze the patients with and without fracture stem and find out the possible risk factors. Methods: From 2006 to 2012, a total of 251 revision long stems (Zimmer, Warsaw, IN) were implanted. In the same period, 17 broken stems that underwent treatment were included for analysis. Patients' demographic data, pattern of femoral bone loss, stem size, medial calcar support in the proximal region of the stem, and the timing of stem breakage were collected and analyzed. Results: The stem size in patients with a broken stem was smaller (p < 0.001), and medial calcar defect was 12.4% and 100% (p < 0.001), respectively. The bone defect was greater in broken group (p = 0.024). The mean duration between revision surgery and stem breakage was 58.07 +/- 36.98 months. Smaller stem size, greater bone defect, and inadequate medial calcar bone support were major risk factors for stem breakage. Conclusions: Bypass fixation in the distal diaphysis with a long stem prosthesis without adequate bone support over medial calcar area may cause stress concentration in the long stem and a fatigue fracture. Use of a smaller prosthesis is the major risk of stem broken. It is essential to repair the proximal femoral bone deficiency and implant selection for better metaphyseal engagement to prevent further stem complications.