Browsing by Author "Shiu, Yan-Ting"
Now showing 1 - 2 of 2
- Results Per Page
- Sort Options
Item type:Item, MicroRNA-92a Mediates Endothelial Dysfunction in CKD(2017-11-01) ;Shang, Fenqing ;Wang, Shen-Chih ;Hsu, Chien-Yi ;Miao, YifeiMartin, MarcyCKD is an independent risk factor for cardiovascular disease (CVD). The accumulation of uremic toxins in CKD induces oxidative stress and endothelial dysfunction. MicroRNA-92a (miR-92a) is induced by oxidative stress in endothelial cells (ECs) and involved in angiogenesis and atherosclerosis. We investigated a role for oxidative stress responsive miR-92a in CKD. Our study of patients at three clinical sites showed increased serum miR-92a level with decreased kidney function. In cultured ECs, human CKD serum or uremic toxins (such as indoxyl sulfate), compared with non-CKD serum, induced the levels of miR-92a and suppressed the expression of miR-92a targets, including key endothelial-protective molecules. The antioxidant N-acetylcysteine inhibited these vasculopathic properties. In rats, adenine-induced CKD associated with increased levels of miR-92a in aortas, serum, and CD144(+) endothelial microparticles. Furthermore, CD144(+) microparticles from human uremic serum contained more miR-92a than those from control serum. Additional analysis showed a positive correlation between serum levels of miR-92a and indoxyl sulfate in a cohort of patients with ESRD undergoing hemodialysis. Collectively, our findings suggest that the uremic toxins accumulated in CKD can upregulate miR-92a in ECs, which impairs EC function and predisposes patients to CVD.Item type:Item, The Anastomotic Angle of Hemodialysis Arteriovenous Fistula Is Associated With Flow Disturbance at the Venous Stenosis Location on Angiography(2020-07-23) ;Yang, Chih-Yu ;Li, Ming-Chia ;Lan, Chien-Wen ;Lee, Wang-JiunLee, Chen-JuThe juxta-anastomotic stenosis of an arteriovenous fistula (AVF) is a significant clinical problem in hemodialysis patients with no effective treatment. Previous studies of AV anastomotic angles on hemodynamics and vascular wall injury were based on computational fluid dynamics (CFD) simulations using standardized AVF geometry, not the real-world patient images. The present study is the first CFD study to use angiographic images with patient-specific outcome information, i.e., the exact location of the AVF stenotic lesion. We conducted the CFD analysis utilizing patient-specific AVF geometric models to investigate hemodynamic parameters at different locations of an AVF, and the association between hemodynamic parameters and the anastomotic angle, particularly at the stenotic location. We analyzed 27 patients who used radio-cephalic AVF for hemodialysis and received an angiographic examination for juxta-anastomotic stenosis. The three-dimensional geometrical model of each patient's AVF was built using the angiographic images, in which the shape and the anastomotic angle of the AVF were depicted. CFD simulations of AVF hemodynamics were conducted to obtain blood flow parameters at different locations of an AVF. We found that at the location of the stenotic lesion, the AV angle was significantly correlated with access flow disturbance (r= 0.739;p< 0.001) and flow velocity (r= 0.563;p= 0.002). Furthermore, the receiver operating characteristic (ROC) curve analysis revealed that the AV angle determines the lesion's flow disturbance with a high area under the curve value of 0.878. The ROC analysis also identified a cut-off value of the AV angle as 46.5 degrees, above or below which the access flow disturbance was significantly different. By applying CFD analysis to real-world patient images, the present study provides evidence that an anastomotic angle wider than 46.5 degrees might lead to disturbed flow generation, demonstrating a reference angle to adopt during the anastomosis surgery.