Browsing by Author "Shu, Chi-Min"
Now showing 1 - 3 of 3
- Results Per Page
- Sort Options
Item type:Item, A study of caprolactam storage tank accident through root cause analysis with a computational approach(2017-11-01) ;Liu, Wei-Yi ;Chen, Chiun-Hsun ;Chen, Wei-Ting ;Shu, Chi-Min機械工程學系In Taiwan, the rapid development of the petrochemical industry over the past four decades has resulted in economic progress and technological advancement. However, this success has been accompanied by pollution and sporadic accidents. Numerous accidents related to crude oil and its derivatives have resulted in a loss of life, employee injuries, environmental and property damage, economic decay, social outcry, and even political turmoil. This study investigated a caprolactam storage tank accident through root cause analysis with a computational approach. The previously described approaches returned findings that indicated causes similar to the real cause of this caprolactam accident. The four summarized descriptions of false conditions of the caprolactam explosion can serve as a reference for other investigations into the causes of petrochemical accidents. Reason of the caprolactam storage tank accident was determined by root cause analysis accompanying with a computational approach. (C) 2017 Elsevier Ltd. All rights reserved.Item type:Item, Fire suppression performance of water mist under diverse desmoking and ventilation conditions(2020-01-01) ;Liu, Wei-Yi ;Chen, Chiun-Hsun ;Shu, Yi-Liang ;Chen, Wei-TingShu, Chi-MinThis paper described full-scale tests of water mist fire suppression system under forced desmoking conditions. Pool fire was effectively suppressed in 25.0 and 37.0 s for 1,500.0 (test 1) and 3,000.0 (test 2) mL of oil with no ventilation, respectively. Moreover, under ventilation rates of 50.0 and 75.0 m(3)/min, the suppression time were lengthened to 54.0 s (test 1) and 202.0 s (test 2), and 102.0 s (test 1) and 222.0 s (test 2), correspondingly. However, the smoke exhaust had a strong effect on the water mist to result in fire could not extinguish, when the ventilation rate increased to 120.0 m(3)/min. The temperature distribution during the early period in the scenario of no ventilation has a higher magnitude than those scenarios of 50.0, 75.0, and 120.0 m(3)/min, because combustion proceeds smoothly to result in temperature increased rapidly at no ventilation. Furthermore, similar results presented in smoke concentration distribution at four scenarios (0, 50.0, 75.0, and 120.0 m(3)/min), and combustion occurred steadily at no ventilation to result in more smoke during the early period. This study employed a computer modeling to verify water mist system in a compartment space and determine how the water mist system could be optimized. (C) 2019 Institution of Chemical Engineers. Published by Elsevier B.V. All rights reserved.Item type:Item, Performance of vanadium oxide on multi-walled carbon nanotubes/titanium electrode for supercapacitor application(2011) ;Liu, Ming-Yang ;Hsieh, Tung-Feng ;Hsieh, Chia-Jung ;Chuang, Chia-ChihShu, Chi-MinComposite electrodes based on vertically aligned multi-walled carbon nanotubes (MWCNTs) coated with vanadium oxide (V2O5) have used in supercapacitors. The vanadium (V) oxide (V2O5) cathodically deposited on titanium collector in vanadium oxide solution. The novel supercapacitor performed by V2O5/MWCNTs/Ti electrode in 1.0 M HCl aqueous solution can reach a specific capacitance of 713.3 F/g at 10 mV/s, which is larger than that of MWCNTs/Ti. To characterize the V2O5/MWCNTs/Ti composite electrode, cyclic voltammetry and galvanostatic charge-discharge method were executed, and the morphology of the composite electrode was examined by scanning electron microscope. This nanocomposite electrode greatly enhanced the utilization efficiency of supercapacitor electrode material, low material cost and provided both high capacitance and power density.