Browsing by Author "Sung, Jung-Che"
Now showing 1 - 2 of 2
- Results Per Page
- Sort Options
Item type:Item, Sampling efficiency of low-volume PM10 inlets with different impaction substrates(2019-03-04) ;Thi-Cuc Le ;Shukla, Krishna Kumar ;Sung, Jung-Che ;Li, ZiyiYeh, HuajunThe louvered 16.7 L min(-1) PM10 inlet is commonly used in PM10 and PM2.5 FRM samplers or FEM monitors. Its sampling efficiency is influenced by particle bounce, re-entrainment, and overloading since the PM10 inlet contains a PM10 impactor with an uncoated impaction surface. In this study, a modified PM10 (M-PM10) inlet with an oil-soaked glass fiber filter substrate supported by an oil-soaked porous metal disc was developed to eliminate the particle bounce and overloading effects. The oiled M-PM10 inlet and the traditional PM10 inlets with and without grease coating were collocated at the field for long-term comparison tests. The results show that the traditional uncoated PM10 inlet which is cleaned initially but not cleaned daily afterwards oversamples PM10 concentration after one 24-h sampling day and has the high positive average sampling bias during 14 sampling days due to particle bounce and re-entrainment. The grease-coated PM10 inlet without daily cleaning shows a better performance with a smaller sampling bias, but it still oversamples PM10 concentrations after the first three 24-h sampling days and then undersamples after 10 sampling days due to particle bounce and overloading effects, respectively. In comparison, the M-PM10 inlet shows a good performance with a small average sampling bias during 35 sampling days since vacuum oil wicks up through the deposit to eliminate particle bounce and overloading. It is suggested that the oiled M-PM10 inlet can be used to replace the traditional EPA PM10 inlet and for long-term sampling of over 1 month without the frequent maintenance need. Copyright (c) 2019 American Association for Aerosol ResearchItem type:Item, The performance of the PM2.5 VSCC and oil-wetted M-WINS in long-term field sampling studies(2020-10-15) ;Thi-Cuc Le ;Fu, Chang-Xing ;Sung, Jung-Che ;Li, Zi-YiPui, David Y. H.Most of PM2.5 FRM samplers and FEM monitors use a well impactor ninety-six (WINS) or very sharp cut cyclone (VSCC) to classify particles smaller than 2.5 mu m in diameter. However, the WINS has the particle loading effect and needs to be cleaned after 3 to 5 sampling days. The VSCC was claimed not to be affected by the particle loading effect in a laboratory study but without the support of field studies. In this field comparison study using daily cleaned VSCC as the reference, the uncleaned VSCC showed overall good performance in three long-term testing periods: period #1 (21 days), period #2 (124 days), and period #3 (30 days). However the fluctuation in PM2.5 concentrations of the uncleaned VSCC occurred in day 14 (D14) and D16 of period #1 due to particle bounce and re-entrainment effects; and also in D19, D31 and D44 of period #2, and in D28 and D29 of period #3 due to particle loading effect. After the sampling periods longer than 21 days in period #2 and #3, the particle loading effect resulted in persistently lower PM2.5 concentrations due to smaller cut-sizes and smoother penetration curves. In comparison, the oil-wetted M-WINS designed by our group showed a better performance with less than +/- 5% bias and +/- 2 mu g m(-3) concentration difference during two long-term tests: periods #2 and #3. This study proved once again that the M-WINS is a viable PM2.5 sampling inlet that meets the long-term PM2.5 sampling or monitoring need.