Browsing by Author "Sung, Yu-Chien"
Now showing 1 - 2 of 2
- Results Per Page
- Sort Options
Item type:Item, Chiral liquid crystals as biosensing platforms(2016-01-01) ;Lee, Mon-Juan ;Sung, Yu-Chien ;Hsiao, Yu-Cheng ;Lee, Wei影像與生醫光電研究所The texture observation has long been the core technique in liquid crystal (LC)-based bioassays. Its working principle stems from the dark-to-bright texture change induced by the interruption of the initially homeotropic alignment in nematic bulks or from the radial-to-bipolar configuration transition in LC droplets in the presence of biomolecules. One of the drawbacks of this observational scheme, which requires a polarizing optical microscope, is the difficulty in quantitative analysis. In this invited paper, we report on our recent development of alternative optical biosensing techniques based on cholesteric LCs (CLCs) without the use of a polarizer. The increase in structural order in a vertically anchored CLC cell in the quasi-planar state provides a means to allow detection and quantification of the concentration of biomolecules immobilized on the interface between the mesophase and the surfactant DMOAP for LC vertical alignment.Item type:Item, Highly sensitive color-indicating and quantitative biosensor based on cholesteric liquid crystal(2015-12-01) ;Hsiao, Yu-Cheng ;Sung, Yu-Chien ;Lee, Mon-Juan ;Lee, Wei影像與生醫光電研究所Liquid crystal (LC)-based biosensors employ highly sensitive interfaces between the alignment layers and LCs to detect biomolecules and their interactions. Present techniques based on optical texture observation of the homeotropic-to-planar response of nematic LCs are limited by their quantitative reproducibility of results, indicating that both the accuracy and reliability of LC-based detection require further improvements. Here we show that cholesteric LC (CLC) can be used as a novel sensing element in the design of an alternative LC-based biosensing device. The chirality of the vertically anchored (VA) CLC was exploited in the detection of bovine serum albumin (BSA), a protein standard commonly used in protein quantitation. The color appearance and the corresponding transmission spectrum of the cholesteric phase changed with the concentration of BSA, by which a detection limit of 1 fg/ml was observed. The optical response of the VA CLC interface offers a simple and inexpensive platform for highly sensitive and naked-eye color-indicating detection of biomolecules, and, thus, may facilitate the development of point-of-care devices for the detection of disease-related biomarkers. (C) 2015 Optical Society of America