Browsing by Author "Tang, S. H."
Now showing 1 - 2 of 2
- Results Per Page
- Sort Options
Item type:Item, Development of TDR penetrometer through theoretical and laboratory investigations: 1. Measurement of soil dielectric permittivity(2006-07-01) ;Lin, C. P. ;Tang, S. H. ;Chung, C. C. ;交大名義發表National Chiao Tung UniversityTo better characterize a bulk soil electrically, both the electrical conductivity and dielectric permittivity should be measured. This study developed a time domain reflectometry (TDR) penetrometer to allow simultaneous measurements of dielectric permittivity and electrical conductivity during cone penetration. A TDR penetrometer is formed by placing a multiple-conductor waveguide around a nonconducting shaft. Probe design considerations and calibration methods for measuring dielectric constant were first theoretically discussed and then evaluated through laboratory investigations. A prototype TDR penetrometer was fabricated and used to perform simulated penetration tests in a calibration chamber. The effect of penetration disturbance on dielectric constant is quantitatively reported and explained. The implications of the data that can be measured by the TDR penetrometer are also discussed.Item type:Item, Development of TDR penetrometer through theoretical and laboratory investigations: 2. Measurement of soil electrical conductivity(2006-07-01) ;Lin, C. P. ;Chung, C. C. ;Tang, S. H. ;交大名義發表National Chiao Tung UniversityA TDR penetrometer was introduced to allow simultaneous measurements of dielectric permittivity and electrical conductivity during cone penetration. This study focused on the theoretical development and experimental evaluation of electrical conductivity measurement using the TDR penetrometer. Theoretical development takes into account the cable resistance and nonconducting cone shaft, leading to a new data reduction equation and calibration procedure. Measurement sensitivity and spatial sampling bias were experimentally evaluated for various probe configurations. The results show that the measurement sensitivity of interest may be controlled by the geometric factor of the probe. The complication and implications of the spatial weighting bias are discussed. A prototype TDR penetrometer was calibrated and used to perform simulated penetration tests in a soil. Experimental results do not show significant errors in electrical conductivity due to the penetration disturbance, verifying the effectiveness of the TDR penetrometer for electrical conductivity measurement.