Browsing by Author "Tsai, Yi-Chun"
Now showing 1 - 3 of 3
- Results Per Page
- Sort Options
Item type:Item, A wearable infrared videopupillography with multi-stimulation of consistent illumination for binocular pupil response(2016-01-01) ;Ou-Yang, Mang ;Lan, Ko Mei ;Tsai, Yi-Chun ;Chiou, Jin-ChernHuang, Ting-WeiThe pupil response to light can reflect various kinds of diseases which are related to physiological health. Pupillary abnormalities may be influenced on people by autonomic neuropathy, glaucoma, diabetes, genetic diseases, and high myopia. In the early stage of neuropathy, it is often asymptomatic and difficulty detectable by ophthalmologists. In addition, the position of injured nerve can lead to unsynchronized pupil response for human eyes. In our study, we design the pupilometer to measure the binocular pupil response simultaneously. It uses the different wavelength of LEDs such as white, red, green and blue light to stimulate the pupil and record the process. Therefore, the pupilometer mainly contains two systems. One is the image acquisition system, it use the two cameras modules with the same external triggered signal to capture the images of the pupil simultaneously. The other one is the illumination system. It use the boost converter ICs and LED driver ICs to supply the constant current for LED to maintain the consistent luminance in each experiments for reduced experimental error. Furthermore, the four infrared LEDs are arranged nearby the stimulating LEDs to illuminate eyes and increase contrast of image for image processing. In our design, we success to implement the function of synchronized image acquisition with the sample speed in 30 fps and the stable illumination system for precise measurement of experiment.Item type:Item, Design of synchronizing pupillometer for observing nerve conduction by pupillary responses(2016) ;Tsai, Yi-Chun ;Yan, Yung-Jhe ;Ko, Mei-Lan ;Huang, Ting-WeiChiou, Jin-ChernThe pupil response to light can reflect various kinds of neural diseases, and different response for two eyes can be analyzed relative afferent pupillary defect. This study presents the novel wearable pupillometer for recording the pupil response and designs the experiment for verifying the synchronization of two cameras. Compared with other devices, the main feature of this study is proven reliable, portable, and wearable for obtaining the pupil response. In addition, our experimental result verify that the pupillometer successfully achieve the function of synchronization.Item type:Item, Multi-band filter design with less total film thickness for short-wave infrared(2017-01-01) ;Yan, Yung-Jhe ;Chien, I-Pen ;Chen, Po-Han ;Chen, Sheng-HuiTsai, Yi-ChunA multi-band pass filter array was proposed and designed for short wave infrared applications. The central wavelength of the multi-band pass filters are located about 905 nm, 950 nm, 1055 nm and 1550 nm. In the simulation of an optical interference band pass filter, high spectrum performance (high transmittance ratio between the pass band and stop band) relies on (1) the index gap between the selected high/low-index film materials, with a larger gap correlated to higher performance, and (2) sufficient repeated periods of high/low-index thin-film layers. When determining high and low refractive index materials, spectrum performance was improved by increasing repeated periods. Consequently, the total film thickness increases rapidly. In some cases, a thick total film thickness is difficult to process in practice, especially when incorporating photolithography liftoff. Actually the maximal thickness of the photoresist being able to liftoff will bound the total film thickness of the band pass filter. For the application of the short wave infrared with the wavelength range from 900nm to 1700nm, silicone was chosen as a high refractive index material. Different from other dielectric materials used in the visible range, silicone has a higher absorptance in the visible range opposite to higher transmission in the short wave infrared. In other words, designing band pass filters based on silicone as a high refractive index material film could not obtain a better spectrum performance than conventional high index materials like TiO2 or Ta2O5, but also its material cost would reduce about half compared to the total film thickness with the conventional material TiO2. Through the simulation and several experimental trials, the total film thickness below 4 um was practicable and reasonable. The fabrication of the filters was employed a dual electric gun deposition system with ion assisted deposition after the lithography process. Repeating four times of lithography and deposition process and black matrix coating, the optical device processes were completed.