Browsing by Author "Wan, Kai Tai"
Now showing 1 - 2 of 2
- Results Per Page
- Sort Options
Item type:Item, Development of low drying shrinkage foamed concrete and hygro-mechanical finite element model for prefabricated building fascade applications(2018-03-20) ;Wan, Kai Tai ;Zhu, Honggang ;Yuen, Terry Y. P. ;Chen, BinmengHu, ChuanlinPrefabricated lightweight concrete building fascade can improve the energy efficiency of buildings and reduce the carbon emission of transportation. However, it is essential to maintain the dimensional stability of the full scale element. The drying shrinkage of lightweight foamed concrete was investigated in this study. The hypothesis of using the drying shrinkage of normal weight concrete to approximate that of lightweight foamed concrete of dry density about 1500 kg/m(3) counterpart was verified. Three different strategies of reducing drying shrinkage were studied. The drying shrinkage of common ingredients of ordinary Portland cement (OPC) and ground granulated blast-furnace slag (GGBS) was commonly up to 2000-3000 mu epsilon. The use of magnesium expansive agent with different calcination conditions could not reduce the drying shrinkage. The use of calcium sulfoaluminate (CSA) cement with OPC and GGBS could significantly reduce the drying shrinkage within 1000 me in standard testing environment. The formulation developed in laboratory was scaled up in a concrete production plant for prefabricated concrete elements. A lightweight full scale panel (the wet density was about 1700 kg/m(3)) was fabricated. The drying shrinkage of the developed formulation with CSA cement was only 161 mu epsilon in the field test. A hygro-mechanical model was developed to model the diffusion, shrinkage and plastic strain evolution. The incremental stress-strain constitutive relationship of the hygro-mechanical model was derived for incorporating it into general finite element routine. The model parameters were calibrated by the drying shrinkage measurements in this study. The calibrated model demonstrated the cracking potential of three typical reinforced concrete panels of three different formulations studied in this study. (C) 2018 Elsevier Ltd. All rights reserved.Item type:Item, Large Structural Shear Deformation and Failure Monitoring Using Bend Losses in Polymer Optical Fibre(2020-01-01) ;Yuen, Terry Y. P. ;Tsai, Cheng-An ;Deb, Trissa ;Lin, Yu-HsiangNyienyi, JuneRapid identification of structural damage positions is essential to the post-disaster rehabilitation of structures and infrastructures. Large shear deformation, e.g., shear failure of bridge piers, shear-slip of slopes, and shear cracking of structural walls, is often the cause of structural instability. Distributed optical fibre sensing (DOFS) techniques have an advantage over point-based sensors in terms of spatial continuous structural condition monitoring. This paper presents the development of new measurement theory and algorithm to evaluate the structural shear deflection based on the large beam deflection and optical bend loss theories. The proposed technique adopted a photon-counting Optical Time Domain Reflectometer (nu-OTDR) with polymer optical fibres (POFs) which has a large deformation measurement range and high spatial resolution. In the experiment, shear deformation events can be successfully detected and evaluated from the proposed technique. When the normalised shear deformation is larger than 0.2, both the event locations and the magnitudes can be accurately determined. When normalised shear deformation is lesser than 0.2, the error in the magnitude evaluation increased, but the event location can be found with an absolute error <0.5 m. Multiple shear events can be treated as independent events when they are separated by more than 5 m. Various configurations of POFs attached to concrete beam specimens for rupture failure monitoring were also studied. The configuration that could maximise the POF curvature at the beam failure produced the largest nu-OTDR signals. In other configurations in which the POFs were only stretched at failure, the signals were less strong and were influenced by the POF-structure bonding strength.