Browsing by Author "Wang, Shin-Li"
Now showing 1 - 2 of 2
- Results Per Page
- Sort Options
Item type:Item, Highly Sensitive Lead Ion Detection in One Drop of Human Whole Blood Using Impedance-Modulated Field-Effect Transistors and a Portable Measurement Device(2020-06-29) ;Wang, Shin-Li ;Hsieh, Ching-Yen ;Sukesan, Revathi ;Chen, Jung-ChihWang, Yu-LinThis study reports the development of a rapid heavy metal ion screening tool for whole blood samples. The test system consists of an ion selective membrane-based impedance modulated field effect transistor (FET) sensor and a portable sensor measurement unit. This study focuses on the direct detection of lead ions in whole blood, without extensive sample pre-treatments. The sensing methodology is based on impedance changes in the membrane due to the specific ionophore-target metal ion interaction in the presence of a strong electric field. The changes in impedance caused by heavy metal ions are amplified by the FET to obtain a highly sensitive lead ion detection, with very low detection limit (near 10(-11) similar to 10(-10)M Pb2+). To reduce the complexity and enhance sensor performance, the whole blood samples are fractionated on chip without any external actuation/automation using simple gravitational blood cell separation. The test results in PBS, human serum and whole blood samples demonstrate high sensitivity and wide dynamic range of lead ion detection. The miniaturized extended gate FET sensor system is ideal for point of care and home-care diagnostics for heavy metal ion in blood.Item type:Item, Rapid and Highly Sensitive Extended Gate FET-Based Sensors for Arsenite Detection Using a Handheld Device(2020-01-12) ;Tatavarthi, Sai Sudheer ;Wang, Shin-Li ;Wang, Yu-Lin ;Chen, Jung-Chih分子醫學與生物工程研究所Heavy metals are very harmful to the environment and is toxic which affects the human health. Monitoring the heavy metal ion in food and water is necessary. In this research, we developed a FET based ion selective sensor for detecting Arsenite (As(III)) ions by a hand held device. The sensor characteristics are carried out and illustrated. This selective sensor shows higher sensitivity (35.19 mV/log [As3+]) than the ideal Nernstian slope. The dynamic range of the Arsenite based ion sensor is from 10(-10)M to 10(-4)M. The detection limit of this FET based ion selective sensor is below 10(-10)M and is comparable to ICP-MS. The sensor captures the particular target ion and is not affected by the interfering ions such as Cadmium and Lead. The sensitivity and selectivity characteristics are comparatively better than the traditional potentiometric Ion selective electrode (ISE). The sensor has shorter response time and is easy to operate. This sensor is affordable for everyone and convenient to use for monitoring the food and drinking water frequently.