Browsing by Author "Wang, Yijun"
Now showing 1 - 5 of 5
- Results Per Page
- Sort Options
Item type:Item, Cell-phone Based Drowsiness Monitoring and Management System(2012) ;Wang, Yu-Te ;Cheng, Chung-Kuan ;Huang, Kuan-Chih ;Lin, Chin-TengWang, YijunIn recent years, driving fatigue and cognitive lapses have gained increasing attentions in the fields of public security, especially regarding the safe manipulation of vehicles. Studies have explored the relation between electroencephalogram (EEG) and driving behavior and several of them further proposed effective approaches (e. g., auditory feedback) to arouse subjects from drowsiness. However, these studies were performed under laboratory-oriented configurations using tethered, ponderous EEG equipment. In real environments, the setup of bulky cognitive monitoring equipment with a long-prep time is not feasible. Therefore, this study extends previous laboratory work by developing an on-line Drowsiness Monitoring and Management (DMM) System featuring a mobile wireless dry-sensor EEG headgear and a cell-phone based real-time EEG processing platform. The DMM system can continuously observe EEG dynamics, deliver arousing feedback to users experiencing momentary cognitive lapses, and assess the efficacy of the feedback in near real-time.Item type:Item, Detecting Glaucoma With a Portable Brain-Computer Interface for Objective Assessment of Visual Function Loss(2017-06-01) ;Nakanishi, Masaki ;Wang, Yu-Te ;Jung, Tzyy-Ping ;Zao, John K.Chien, Yu-YiIMPORTANCE The current assessment of visual field loss in diseases such as glaucoma is affected by the subjectivity of patient responses and the lack of portability of standard perimeters. OBJECTIVE To describe the development and initial validation of a portable brain-computer interface (BCI) for objectively assessing visual function loss. DESIGN, SETTING, AND PARTICIPANTS This case-control study involved 62 eyes of 33 patients with glaucoma and 30 eyes of 17 healthy participants. Glaucoma was diagnosed based on a masked grading of optic disc stereophotographs. All participants underwent testing with a BCI device and standard automated perimetry (SAP) within 3 months. The BCI device integrates wearable, wireless, dry electroencephalogram and electrooculogram systems and a cellphone-based head-mounted display to enable the detection of multifocal steady state visual-evoked potentials associated with visual field stimulation. The performances of global and sectoral multifocal steady state visual-evoked potentials metrics to discriminate glaucomatous from healthy eyes were compared with global and sectoral SAP parameters. The repeatability of the BCI device measurements was assessed by collecting results of repeated testing in 20 eyes of 10 participants with glaucoma for 3 sessions of measurements separated by weekly intervals. MAIN OUTCOMES AND MEASURES Receiver operating characteristic curves summarizing diagnostic accuracy. Intraclass correlation coefficients and coefficients of variation for assessing repeatability. RESULTS Among the 33 participants with glaucoma, 19 (58%) were white, 12 (36%) were black, and 2 (6%) were Asian, while among the 17 participants with healthy eyes, 9 (53%) were white, 8 (47%) were black, and none were Asian. The receiver operating characteristic curve area for the global BCI multifocal steady state visual-evoked potentials parameter was 0.92 (95% CI, 0.86-0.96), which was larger than for SAP mean deviation (area under the curve, 0.81; 95% CI, 0.72-0.90), SAP mean sensitivity (area under the curve, 0.80; 95% CI, 0.69-0.88; P = .03), and SAP pattern standard deviation (area under the curve, 0.77; 95% CI, 0.66-0.87; P = .01). No statistically significant differences were seen for the sectoral measurements between the BCI and SAP. Intraclass coefficients for global and sectoral parameters ranged from 0.74 to 0.92, and mean coefficients of variation ranged from 3.03% to 7.45%. CONCLUSIONS AND RELEVANCE The BCI device may be useful for assessing the electrical brain responses associated with visual field stimulation. The device discriminated eyes with glaucomatous neuropathy from healthy eyes in a clinically based setting. Further studies should investigate the feasibility of the BCI device for home-based testing as well as for detecting visual function loss over time.Item type:Item, Habituation of Steady-State Visual Evoked Potentials in response to High-Frequency Polychromatic Foveal Visual Stimulation(2013) ;Kuo, Heng-Yuan ;Chiu, George C. ;Zao, John K. ;Lai, Kuan-LinGruber, AllenIn an attempt to develop safe and robust methods for monitoring migraineurs\' brain states, we explores the feasibility of using white, red, green and blue LED lights flickering around their critical flicker fusion (CFF) frequencies as foveal visual stimuli for inducing steady-state visual evoked potentials (SSVEP) and causing discernible habituation trends. After comparing the habituation indices, the multi-scale entropies and the time dependent intrinsic correlations of their SSVEP signals, we reached a tentative conclusion that sharp red and white light pulses flickering barely above their CFF frequencies can replace commonly used 13Hz stimuli to effectively cause SSVEP habituation among normal subjects. Empirical results showed that consecutive short bursts of light can produce more consistent responses than a single prolonged stimulation. Since these high frequency stimuli do not run the risk of triggering migraine or seizure attacks, further tests of these stimuli on migraine patients are warranted in order to verify their effectiveness.Item type:Item, Polychromatic SSVEP stimuli with subtle flickering adapted to brain-display interactions(2017-02) ;Chien, Yu-Yi ;Lin, Fang-Cheng ;Zao, John K. ;Chou, Ching-ChiHuang, Yi-PaiObjective. Interactive displays armed with natural user interfaces (NUIs) will likely lead the next breakthrough in consumer electronics, and brain-computer interfaces (BCIs) are often regarded as the ultimate NUI-enabling machines to respond to human emotions and mental states. Steady-state visual evoked potentials (SSVEPs) are a commonly used BCI modality due to the ease of detection and high information transfer rates. However, the presence of flickering stimuli may cause user discomfort and can even induce migraines and seizures. With the aim of designing visual stimuli that can be embedded into video images, this study developed a novel approach to induce detectable SSVEPs using a composition of red/green/ blue flickering lights. Approach. Based on the opponent theory of colour vision, this study used 32 Hz/40 Hz rectangular red-green or red-blue LED light pulses with a 50% duty cycle, balanced/ equal luminance and 0 degrees/180 degrees phase shifts as the stimulating light sources and tested their efficacy in producing SSVEP responses with high signal-to-noise ratios (SNRs) while reducing the perceived flickering sensation. Main results. The empirical results from ten healthy subjects showed that dual-colour lights flickering at 32 Hz/40 Hz with a 50% duty cycle and 180 degrees phase shift achieved a greater than 90% detection accuracy with little or no flickering sensation. Significance. As a first step in developing an embedded SSVEP stimulus in commercial displays, this study provides a foundation for developing a combination of three primary colour flickering backlights with adjustable luminance proportions to create a subtle flickering polychromatic light that can elicit SSVEPs at the basic flickering frequency.Item type:Item, SNR Analysis of High-Frequency Steady-State Visual Evoked Potentials from the Foveal and Extrafoveal Regions of Human Retina(2012) ;Lin, Fang-Cheng ;Zao, John K. ;Tu, Kuan-Chung ;Wang, YijunHuang, Yi-PaiWith brain-computer interface (BCI) applications in mind, we analyzed the amplitudes and the signal-to-noise ratios (SNR) of steady-state visual evoked potentials (SSVEP) induced in the foveal and extra-foveal regions of human retina. Eight subjects (age 20-55) have been exposed to 2 degrees circular and 16 degrees-18 degrees annular visual stimulation produced by white LED lights flickering between 5Hz and 65Hz in 5Hz increments. Their EEG signals were recorded using a 64-channel NeuroScan system and analyzed using non-parametric spectral and canonical convolution techniques. Subjects' perception of flickering and their levels of comfort towards the visual stimulation were also noted. Almost all subjects showed distinctively higher SNR in their foveal SSVEP responses between 25Hz and 45Hz. They also noticed less flickering and felt more comfortable with the visual stimulation between 30Hz and 45Hz. These empirical evidences suggest that lights flashing above the critical flicker fusion rates (CFF) of human vision may be used as effective and comfortable stimuli in SSVEP BCI applications.