Browsing by Author "Yin, Gung-Chian"
Now showing 1 - 10 of 10
- Results Per Page
- Sort Options
Item type:Item, 30 nm resolution x-ray imaging at 8 keV using third order diffraction of a zone plate lens objective in a transmission microscope(2006-11-27) ;Yin, Gung-Chian ;Song, Yen-Fang ;Tang, Mau-Tsu ;Chen, Fu-RongLiang, Keng S.A hard x-ray transmission microscope with 30 nm spatial resolution has been developed employing the third diffraction order of a zone plate objective. The microscope utilizes a capillary type condenser with suitable surface figure to generate a hollow cone illumination which is matched in illumination range to the numerical aperture of the third order diffraction of a zone plate with an outmost zone width of 50 nm. Using a test sample of a 150 nm thick gold spoke pattern with finest half-pitch of 30 nm, the authors obtained x-ray images with 30 nm resolution at 8 keV x-ray energy. (c) 2006 American Institute of Physics.Item type:Item, Capabilities of time-resolved X-ray excited optical luminescence of the Taiwan Photon Source 23A X-ray nanoprobe beamline(2020-01-01) ;Lin, Bi-Hsuan ;Wu, Yu-Hao ;Li, Xiao-Yun ;Hsu, Hsu-ChengChiu, Yu-ChengTime-resolved X-ray excited optical luminescence (TR-XEOL) was developed successfully for the 23A X-ray nanoprobe beamline located at the Taiwan Photon Source (TPS). The advantages of the TR-XEOL facility include (i) a nano-focused X-ray beam (<60 nm) with excellent spatial resolution and (ii) a streak camera that can simultaneously record the XEOL spectrum and decay time. Three time spans, including normal (30 ps to 2 ns), hybrid (30 ps to 310 ns) and single (30 ps to 1.72 mu s) bunch modes, are available at the TPS, which can fulfil different experimental conditions involving samples with various lifetimes. It is anticipated that TR-XEOL at the TPS X-ray nanoprobe could provide great characterization capabilities for investigating the dynamics of photonic materials.Item type:Item, Dark field image of full-field transmission hard x-ray microscope in 8-11 keV(2006-01-01) ;Yin, Gung-Chian ;Duewer, Fred ;Zeng, Xianghui ;Lyon, AlanYun, WenbingWe have demonstrated dark-field imaging using a full-field hard x-ray microscope by using a custom capillary-based condenser. The condenser provides illumination with a numeric aperture about 3-mrad with high efficiency. This high illumination angle allows full-resolution imaging using a 50 rim hard x-ray zone plate. The zeroth order beam from the condenser is well out of the zoneplate range - which allows a high signal-to-noise ratio in the image plane. Small particles with high scattering power, such as colloidal gold markers used in biology are well-suited for dark-field imaging. Combining with high brightness source from NSRRC BL01B, the dark field image can be acquired within several minutes with high contrast ratio. In this paper, the dark field image of IC and the zoneplate defect will be demonstrated and studied in different energy under dark field mode.Item type:Item, Investigation of Cavity Enhanced XEOL of a Single ZnO Microrod by Using Multifunctional Hard X-ray Nanoprobe(2019-01-18) ;Lin, Bi-Hsuan ;Li, Xiao-Yun ;Lin, Dai-Jie ;Jian, Bo-LunHsu, Hsu-ChengThe multifunctional hard X-ray nanoprobe at Taiwan Photon Source (TPS) exhibits the excellent ability to simultaneously characterize the X-ray absorption, X-ray excited optical luminescence (XEOL) as well as the dynamics of XEOL of materials. Combining the scanning electron microscope (SEM) into the TPS 23A end-station, we can easily and quickly measure the optical properties to map out the morphology of a ZnO microrod. A special phenomenon has been observed that the oscillations in the XEOL associated with the confinement of the optical photons in the single ZnO microrod shows dramatical increase while the X-ray excitation energy is set across the Zn K-edge. Besides having the nano-scale spatial resolution, the synchrotron source also gives a good temporal domain measurement to investigate the luminescence dynamic process. The decay lifetimes of different emission wavelengths and can be simultaneously obtained from the streak image. Besides, SEM can provide the cathodoluminescence (CL) to be a complementary method to analyze the emission properties of materials, we anticipate that the X-ray nanoprobe will open new avenues with great characterization ability for developing nano/microsized optoelectronic devices.Item type:Item, Observation of anomalous emissions of nonpolar a-plane MgZnO and ZnO epi-films based on XEOL and time-resolved XEOL in hybrid bunch mode(2020-08-01) ;Lin, Bi-Hsuan ;Wu, Yu-Hao ;Wu, Yung-Chi ;Liu, Wei-ReinLee, Chien-YuX-ray excited optical luminescence (XEOL) using an x-ray nanobeam operating in the hybrid bunch mode provides not only a sufficiently high peak power density but also high-quality temporal domain measurements for studying the luminescence dynamics of photonic materials and devices. We used these features to investigate the peculiar emission behavior of the as-grown and rapid thermal annealing (RTA)-treated a-plane MgZnO epi-films, from which an anomalous emission was observed at similar to 325 nm, along with a rapid increase in near-band edge (NBE) emission with increasing x-ray irradiation time. This peculiar emission behavior was also observed in the cathodoluminescence spectra obtained under electron beam excitation. Increases in the NBE emission intensity of the RTA-treated a-plane MgZnO epi-film were observed in terms of both photoluminescence and small anomalous emissions of XEOL. This can be explained by the effective transfer of Mg atoms from interstitial sites to suitable sites as a result of RTA treatment. Based on comparison with an a-plane ZnO epi-film without Mg, we conclude that the anomalous emission peak is caused by Mg-related energy states created by the high-dose x-ray or electron beam irradiation. Furthermore, the rapid increase in NBE emission and the reduction in the long decay lifetime can be attributed to charge transfer from the Mg clusters, which are thus responsible for the anomalous emissions.Item type:Item, Peculiar near-band-edge emission of polarization-dependent XEOL from a non-polar a-plane ZnO wafer(2018-02-05) ;Lin, Bi-Hsuan ;Wu, Yung-Chi ;Chen, Huang-Yeh ;Tseng, Shao-ChinWu, Jian-XingPolarization-dependent hard X-ray excited optical luminescence (XEOL) was used to study not only the optical properties but also the crystallographic orientations of a non-polar a-plane ZnO wafer. In addition to a positive-edge jump and extra oscillations in the near-band-edge (NBE) XEOL yield, we observed a blue shift of the NBE emission peak that follows the polarization-dependent X-ray absorption near-edge structure (XANES) as the X-ray energy is tuned across the Zn K-edge. This NBE blue shift is caused by the larger X-ray absorption, generating higher free carriers to reduce the exciton-LO phonon coupling, which causes a decrease in the exciton activation energy. The extra oscillations in XANES and XEOL as the polarization is set parallel to the c-axis is attributed to simultaneous excitations of the Zn 4p - O 2p pi-bond along the c-axis and the bilayer sigma-bond, whereas only the sigma-bond is excited when the polarization is perpendicular to the c-axis. The polarization-dependent XEOL spectra can be used to determine the crystallographic orientations. (c) 2018 Optical Society of America under the terms of the OSA Open Access Publishing AgreementItem type:Item, Phase tomography reconstructed by 3D TIE in hard X-ray microscope(2007) ;Yin, Gung-Chian ;Chen, Fu-Rong ;Pyun, Ahram ;Ho, JungHwu, YeukuangX-ray phase tomography and phase imaging are promising ways of investigation on low Z material- A polymer blend of PE/PS sample was used to test the 3D phase retrieval method in the parallel beam illuminated microscope. Because the polymer sample is thick, the phase retardation is quite mixed and the image can not be distinguished when the 2D transport intensity equation (TIE) is applied. In this study, we have provided a different approach for solving the phase in three dimensions for thick sample. Our method involves integration of 3D TIE/Fourier slice theorem for solving thick phase sample. In our experiment, eight sets of de-focal series image data sets were recorded covering the angular range of 0 to 180 degree. Only three set of image cubes were used in 3D TIE equation for solving the phase tomography. The phase contrast of the polymer blend in 3D is obviously enhanced, and the two different groups of polymer blend can be distinguished in the phase tomography.Item type:Item, Probing the exciton-phonon coupling strengths of O-polar and Zn-polar ZnO wafer using hard X-ray excited optical luminescence(2016-11-07) ;Lin, Bi-Hsuan ;Chen, Huang-Yeh ;Tseng, Shao-Chin ;Wu, Jian-XingChen, Bo-YiThe temperature-dependent hard X-ray excited optical luminescence (XEOL) spectroscopy was used to study the optical properties of O and Zn polarity of a c-plane single crystal ZnO wafer. By analyzing the XEOL and XRD, we found an unprecedented blue shift of the free exciton transition with increasing the excited carrier density as tuning the X-ray energy across the Zn K-edge, and the O-polar face possesses better crystal structure than the Zn-polar one. This spectral blue shift is attributed to the Coulomb screening of the spontaneous polarization by the excited free carriers that result in decreasing the exciton-phonon Frohlich interaction to reduce exciton binding energy. Published by AIP Publishing.Item type:Item, Quantitative phase retrieval in transmission hard x-ray microscope(2007-04-30) ;Yin, Gung-Chian ;Chen, Fu-Rong ;Hwu, Yeukuang ;Shieh, Han-Ping D.Liang, Keng S.Quantitative phase retrieval with a sub-100-nm resolution is achieved from micrographs of a zone plate based transmission x-ray microscope. A plastic zone plate containing objects of sizes from micrometers down to tens of nanometers is used as a test sample to quantify the retrieved phase. Utilizing the focal serial images in the image plane, the phase information is retrieved quantitatively across the entire range of sizes by combining the transport intensity equation and self-consistent wave propagation methods in this partial coherence system. The study demonstrates a solution to overcome the deficiency encountered in the two phase retrieval approaches. (c) 2007 American Institute of Physics.Item type:Item, Zone plate tilt study in transmission X-ray microscope system at 8-11 keV(2009) ;Chao, Fu-Han ;Yin, Gung-Chian ;Liang, Keng S. ;Lai, Yin-Chieh光電工程學系Zone plate [1] has been used as a focal lens in transmission X-ray microscope (TXM) optical system in recent decades [2, 3]. In TXM of NSRRC[4,5], the thickness of zone plate is about 900nm and the width of its out most zones is 50nm, which has a high aspect ratio 18. When zone plate is tilted, the image quality will be affected by aberration. Since the aspect ratio of zone plate is large, for incident beam, the shape of zone plate's transmission function will look different when zone plate is tilted. The both experimental and simulation result will be shown in this present. A five axes stage is designed and manufactured for the zone plate holder for three dimensional movement, tip and tilt. According to Fourier theory, we can calculate the wave distribution on image plane, if we know the original wave function, the distances between each element, and the transparencies of the sample and zone plate. A parallel simulation process code in MATLAB is developed in workstation cluster with up to 128Gbytes memory. The effects of aberration generated by tilt effect are compared from the experimental data and simulation result. A maximum tilt angle within the acceptable image quality is calculated by simulation and will be verified by experiment.