Browsing by Author "Yu, Shiang-Yi"
Now showing 1 - 3 of 3
- Results Per Page
- Sort Options
Item type:Item, A highly selective turn-on fluorescence chemosensor for Hg(II) and its application in living cell imaging(2014-10-01) ;Yu, Shiang-Yi ;Wu, Shu-Pao ;應用化學系Department of Applied ChemistryA new coumarin derivative (MS1) containing an imine moiety and a hydroxyl moiety exhibits an enhanced fluorescence in the presence of Hg2+ ions. Other metal ions Al3+, Ca2+, Co2+, Cr3+, Cu2+, Fe2+, Fe3+, Hg-2+,Hg- Mg2+, Mn2+, Ni2+, Pb2+, and Zn2+ produced only minor changes in the fluorescence values of MS1. The binding ratio of MS1-Hg2+ complexes was determined from the Job plot to be 1:1. The binding constant (Ka) of Hg2+ binding to MS1 was found to be 6.85 x 103 M-1. The maximum fluorescence enhancement caused by Hg2+ binding to MS1 was observed in the pH range of 6.5-9.0. Confocal fluorescence microscopy imaging using RAW 264.7 cells showed that MS1 could be used as an effective fluorescent probe for detecting Hg2+ in living cells. (C) 2014 Elsevier B.V. All rights reserved.Item type:Item, A highly selective turn-on fluorescence chemosensor for Hg(II) and its application in living cell imaging(2014-10-01) ;Yu, Shiang-Yi ;Wu, Shu-Pao ;應用化學系Department of Applied ChemistryA new coumarin derivative (MS1) containing an imine moiety and a hydroxyl moiety exhibits an enhanced fluorescence in the presence of Hg2+ ions. Other metal ions Al3+, Ca2+, Co2+, Cr3+, Cu2+, Fe2+, Fe3+, Hg-2+,Hg- Mg2+, Mn2+, Ni2+, Pb2+, and Zn2+ produced only minor changes in the fluorescence values of MS1. The binding ratio of MS1-Hg2+ complexes was determined from the Job plot to be 1:1. The binding constant (Ka) of Hg2+ binding to MS1 was found to be 6.85 x 103 M-1. The maximum fluorescence enhancement caused by Hg2+ binding to MS1 was observed in the pH range of 6.5-9.0. Confocal fluorescence microscopy imaging using RAW 264.7 cells showed that MS1 could be used as an effective fluorescent probe for detecting Hg2+ in living cells. (C) 2014 Elsevier B.V. All rights reserved.Item type:Item, A hypochlorous acid turn-on fluorescent probe based on HOCl-promoted oxime oxidation and its application in cell imaging(2014-06-01) ;Yu, Shiang-Yi ;Hsu, Chen-Yi ;Chen, Wei-Chieh ;Wei, Ling-FangWu, Shu-PaoA coumarin-based fluorometric probe, HS1, has been successfully developed for highly sensitive and selective detection of hypochlorous acid (HOCl). The probe is based on the specific HOCl-promoted oxidation of oxime. The reaction is accompanied by a 7-fold increase in the fluorescent quantum yield (from 0.03 to 0.21). The fluorescence intensity of the reaction between HOCl and HS1 shows a good linearity in the HOCl concentration range of 1-20 mu M and a low detection limit of 25 nM (S/N = 3). In addition, confocal fluorescence microscopy imaging using RAW264.7 macrophages demonstrates that the HS1 probe could be an efficient fluorescent probe for HOCl in living cells. (C) 2014 Elsevier B.V. All rights reserved.