Browsing by Author "Yu, Yi-Hsin"
Now showing 1 - 7 of 7
- Results Per Page
- Sort Options
Item type:Item, An EEG-based Classification System of Passenger's Motion Sickness Level by using Feature Extraction/Selection Technologies(2010) ;Yu, Yi-Hsin ;Lai, Pei-Chen ;Ko, Li-Wei ;Chuang, Chun-HsiangKuo, Bor-ChenPast studies reported that the main electrogastrography (EEG) dynamic changes related to motion sickness (MS) were occurred in occipital, parietal, and somatosensory brain area, especially in the power increasing of the alpha band (8-13 Hz) and theta band (4-7 Hz) which had positive correlation with the subjective MS level. Depend on these main findings correlated with MS, we attempt to develop an EEG based classification system to automatically classify subject's MS level and find the suitable EEG features via common feature extraction, selection and classifiers technologies in this study. If we can find the regulations and then develop an algorithm to predict MS occurring, it would be a great benefit to construct a safe and comfortable environment for all drivers and passengers when they are cruising in the car, bus, ship or airplane. EEG is one of the best methods for monitoring the brain dynamics induced by motion-sickness because of its high temporal resolution and portability. After collecting the EEG signals and subjective MS level in a realistic driving environment, we first do the data pre-processing part including ICA, component clustering analysis and time-frequency analysis. Then we adopt three common feature extractions and two feature selections (FE/FS) technologies to extract or select the correlated features such as principal component analysis (PCA), linear discriminate analysis (LDA), nonparametric weighted feature extraction (NWFE), forward feature selections (FFS) and backward feature selections (BFS) and feed the feature maps into three classifiers (Gaussian Maximum Likelihood Classifier (ML), k-Nearest-Neighbor Classifier (kNN) and Support Vector Machine (SVM)). Experimental results show that classification performance of all our proposed technologies can be reached almost over 95%. It means it is possible to apply the effective technology combination to predict the subject's MS level in the real life applications. The better combination in this study is using LDA and Gaussian based ML classifier. This advantage can be widely used in machine learning area for developing the prediction algorithms in the future.Item type:Item, An Inflatable and Wearable Wireless System for Making 32-Channel Electroencephalogram Measurements(2016-07) ;Yu, Yi-Hsin ;Lu, Shao-Wei ;Chuang, Chun-Hsiang ;King, Jung-TaiChang, Che-LunPotable electroencephalography (EEG) devices have become critical for important research. They have various applications, such as in brain-computer interfaces (BCI). Numerous recent investigations have focused on the development of dry sensors, but few concern the simultaneous attachment of high-density dry sensors to different regions of the scalp to receive qualified EEG signals from hairy sites. An inflatable and wearable wireless 32-channel EEG device was designed, prototyped, and experimentally validated for making EEG signal measurements; it incorporates spring-loaded dry sensors and a novel gasbag design to solve the problem of interference by hair. The cap is ventilated and incorporates a circuit board and battery with a high-tolerance wireless (Bluetooth) protocol and low power consumption characteristics. The proposed system provides a 500/250 Hz sampling rate, and 24 bit EEG data to meet the BCI system data requirement. Experimental results prove that the proposed EEG system is effective in measuring audio event-related potential, measuring visual event-related potential, and rapid serial visual presentation. Results of this work demonstrate that the proposed EEG cap system performs well in making EEG measurements and is feasible for practical applications.Item type:Item, Augmented Wire-Embedded Silicon-Based Dry-Contact Sensors for Electroencephalography Signal Measurements(2020-04-01) ;Lin, Chin-Teng ;Yu, Yi-Hsin ;King, Jung-Tai ;Liu, Chi-HsienLiao, Lun-DeThe aim of this study was to develop a novel dry electroencePhalography (EEG) sensor with a soft, pliable pad that conforms to the contours of the skin and skull providing a suitable surface contact area for collecting elec: trical potential signals and ensuring a reliable connection. In this study, based on our experience in developing flexible silver/silicon-based dry-contact sensors (SBDSs) for biognal measurements, we proposed a new, augmented weirle-embedded silicon-based dry-contact sensor (WSBDS) with a long lifespan and better performance in EEG measurements. The following two augmentation concepts were proposed in this design and implemented in fabrication: 1) the addition of a metal stud and 2) the embedding of copper wires into the fingers of an acicular SBDS. The forehead sensor is suitable for forehead EEG measurements, and the acicular sensor is designed for application to hair-covered sites, where it can overcome hair interference to achieve satisfactory scalp contact while maintaining low impedance at the skin-electrode interface. Finally, thisi faugm!nted WSBDS performed well in human EEG recording in a designed brain-computer interface (BCI) experiment and is easiblefor practical applications.Item type:Item, EEG Alpha and Gamma Modulators Mediate Motion Sickness-Related Spectral Responses(2016-03) ;Chuang, Shang-Wen ;Chuang, Chun-Hsiang ;Yu, Yi-Hsin ;King, Jung-TaiLin, Chin-TengMotion sickness (MS) is a common experience of travelers. To provide insights into brain dynamics associated with MS, this study recruited 19 subjects to participate in an electroencephalogram (EEG) experiment in a virtual-reality driving environment. When riding on consecutive winding roads, subjects experienced postural instability and sensory conflict between visual and vestibular stimuli. Meanwhile, subjects rated their level of MS on a six-point scale. Independent component analysis (ICA) was used to separate the filtered EEG signals into maximally temporally independent components (ICs). Then, reduced logarithmic spectra of ICs of interest, using principal component analysis, were decomposed by ICA again to find spectrally fixed and temporally independent modulators (IMs). Results demonstrated that a higher degree of MS accompanied increased activation of alpha (r = 0.421) and gamma (r = 0.478) IMs across remote-independent brain processes, covering motor, parietal and occipital areas. This co-modulatory spectral change in alpha and gamma bands revealed the neurophysiological demand to regulate conflicts among multi-modal sensory systems during MS.Item type:Item, Extracting Patterns of Single-Trial EEG Using an Adaptive Learning Algorithm(2015) ;Lin, Chin-Teng ;Wang, Yu-Kai ;Fang, Chieh-Ning ;Yu, Yi-HsinKing, Jung-TaiThe improvement of brain imaging technique brings about an opportunity for developing and investigating brain-computer interface (BCI) which is a way to interact with computer and environment. The measured brain activities usually constitute the signals of interest and noises. Applying the portable device and removing noise are the benefits to real-world BCI. In this study, one portable electroencephalogram (EEG) system non-invasively acquired brain dynamics through wireless transmission while six subjects participated in the rapid serial visual presentation (RSVP) paradigm. The event-related potential (ERP) was traditionally estimated by ensemble averaging (EA) to increase the signal-to-noise ratio. One adaptive filter of data-reusing radial basis function network (DR-RBFN) was also utilized as the estimator. The results showed that this portable EEG system stably acquired brain activities. Furthermore, the task-related potentials could be clearly explored from the limited samples of EEG data through DR-RBFN. According to the artifact-free data from the portable device, this study demonstrated the potential to move the BCI from laboratory research to real-life application in the near future.Item type:Item, Forehead EEG in support of Future Feasible Personal Healthcare Solutions: Sleep Management, Headache Prevention, and Depression Treatment(2017-01-01) ;Lin, Chin-Teng ;Chuang, Chun-Hsiang ;Cao, Zehong ;Singh, Avinash KumarHung, Chih-ShengThere are current limitations in the recording technologies for measuring EEG activity in clinical and experimental applications. Acquisition systems involving wet electrodes are time-consuming and uncomfortable for the user. Furthermore, dehydration of the gel affects the quality of the acquired data and reliability of long-term monitoring. As a result, dry electrodes may be used to facilitate the transition from neuroscience research or clinical practice to real-life applications. EEG signals can be easily obtained using dry electrodes on the forehead, which provides extensive information concerning various cognitive dysfunctions and disorders. This paper presents the usefulness of the forehead EEG with advanced sensing technology and signal processing algorithms to support people with healthcare needs, such as monitoring sleep, predicting headaches, and treating depression. The proposed system for evaluating sleep quality is capable of identifying five sleep stages to track nightly sleep patterns. Additionally, people with episodic migraines can be notified of an imminent migraine headache hours in advance through monitoring forehead EEG dynamics. The depression treatment screening system can predict the efficacy of rapid antidepressant agents. It is evident that frontal EEG activity is critically involved in sleep management, headache prevention, and depression treatment. The use of dry electrodes on the forehead allows for easy and rapid monitoring on an everyday basis. The advances in EEG recording and analysis ensure a promising future in support of personal healthcare solutions.Item type:Item, New Flexible Silicone-Based EEG Dry Sensor Material Compositions Exhibiting Improvements in Lifespan, Conductivity, and Reliability(2016-11-01) ;Yu, Yi-Hsin ;Chen, Shih-Hsun ;Chang, Che-Lun ;Lin, Chin-TengHairston, W. DavidThis study investigates alternative material compositions for flexible silicone-based dry electroencephalography (EEG) electrodes to improve the performance lifespan while maintaining high-fidelity transmission of EEG signals. Electrode materials were fabricated with varying concentrations of silver-coated silica and silver flakes to evaluate their electrical, mechanical, and EEG transmission performance. Scanning electron microscope (SEM) analysis of the initial electrode development identified some weak points in the sensors' construction, including particle pull-out and ablation of the silver coating on the silica filler. The newly-developed sensor materials achieved significant improvement in EEG measurements while maintaining the advantages of previous silicone-based electrodes, including flexibility and non-toxicity. The experimental results indicated that the proposed electrodes maintained suitable performance even after exposure to temperature fluctuations, 85% relative humidity, and enhanced corrosion conditions demonstrating improvements in the environmental stability. Fabricated flat (forehead) and acicular (hairy sites) electrodes composed of the optimum identified formulation exhibited low impedance and reliable EEG measurement; some initial human experiments demonstrate the feasibility of using these silicone-based electrodes for typical lab data collection applications.