Browsing by Author "Lin, T. C."
Now showing 1 - 4 of 4
- Results Per Page
- Sort Options
Item type:Item, A gasket-type standard leak element using femtosecond laser micromachining(2020-10-01) ;Chan, C. K. ;Tu, C. Y. ;Yeh, S. D. ;Chang, C. C.Lin, T. C.A gasket-type standard leak element with a microfluidic channel was developed and measured. The microfluidic channel with a diameter of several micrometers and a length of one hundred micrometers was fabricated by using femtosecond laser micromachining. The conductances (<1 x 10(-6) L s(-1)) of the micmfluidic channel for various non-condensable gases - H-2, He, CH4, N-2 and CO2 were determined by a measuring system based on conductance modulation (CM) method. The experimental results show that the flow characteristics of our devices exhibit molecular flow at a pressure up to 100 mbar and the conductance values of H-2, He, CH4, N-2 and CO2 are inversely proportional to the square root of their molecular mass.Item type:Item, Electron delocalization of tensily strained GaAs quantum dots in GaSb matrix(2010-12-15) ;Lin, T. C. ;Wu, Y. H. ;Li, L. C. ;Sung, Y. T.Lin, S. D.The magneto-optical response of type-II tensily strained GaAs self-assembled quantum dots in GaSb was investigated in magnetic fields up to 14 T. By depositing different GaAs amount, the dot sizes and the corresponding emission energies were varied. We analyzed the carrier wave function extent of different dots using the diamagnetic shift results. It was found that, with the increase in the energy (the reduction in the dot size), the diamagnetic coefficient first rises quickly and then saturates at around 21 mu eV/T(2). Based on a simple calculation model, this unusual tendency is attributed to the electrons gradually spilling out of the quantum dot to the wetting layer as the dots get smaller. This delocalization effect is enhanced in this material system due to the tensile strain relaxation within the dots, which raises the conduction band edge over that in the wetting layer. (c) 2010 American Institute of Physics. [doi: 10.1063/1.3520669]Item type:Item, Extreme Hyperlactatemia After Heart Transplantation: One Center's Experience(2015-07-01) ;Hsu, Y. C. ;Hsu, C. H. ;Huang, G. S. ;Lu, C. C.Wu, Z. F.Introduction. Hyperlactatemia may occur early after cardiac surgery and is correlated with prognosis. This study was conducted to analyze the perioperative variables and postoperative outcomes among heart transplant recipients with extremely high lactate levels (>15 mmol/L). Methods. The single-center medical records of heart transplantation from June 2006 to May 2013 were retrospectively reviewed for patient characteristics, perioperative hemodynamic variables, arterial blood gas analysis data, and postoperative mortality. Results. Among 58 consecutive heart transplant recipients, lactate levels over the detectable upper limit (>15 mmol/L) were identified in 12 patients after intensive care unit admission, with peak time at 1.9 +/- 2.0 (range 0-6.1) hours. The maximal preoperative lactate level was 3.1 mmol/L, and most (11/12) postoperative lactate levels returned to <4 mmol/L at 27.5 +/- 12.8 hours after surgery (range 15-58, median 24), displaying a trend toward delayed extubation time in 10 recipients (P < .01). Blood glucose levels elevated significantly from preoperative 148.9 +/- 45.2 to 375.7 +/- 96.9 mg/dL at peak lactate level (P < .01). Four patients died in the ICU (range 5-32 days), 4 died after discharge (range 5-57 months), with 6 in total surviving over 1 year. Conclusion. Extreme hyperlactatemia commonly occurred early after heart transplantation and mostly recovered within 30 hours; however, with delayed extubation time after operation.Item type:Item, Type-I/type-II exciton in strained Si/SiGe multi-QWs(2008-03-01) ;Wang, K. Y. ;Huang, W. P. ;Lin, T. C. ;Lee, C. P.Sung, Y. T.Using magneto-luminescence (ML) measurement, we have observed the formation of magneto-excitons with either type-I or type-II band alignment depending on the strain distribution in the Si/SiGe quantum well structures. This observation is consistent with the analysis of strain-induced band shifting and exciton-transition energy. (c) 2007 Elsevier B.V. All rights reserved.