Browsing by Author "Takayama, Toshio"
Now showing 1 - 10 of 10
- Results Per Page
- Sort Options
Item type:Item, 3D pH MEASUREMENT FOR CELL CULTURE USING CT SCAN(2017-01-01) ;Higashino, Nobuya ;Takayama, Toshio ;Ito, Hiroaki ;Horade, MitsuhiroTsai, Chia-Hung DylanIn cell culture, the pH of culture liquid is one of the most important conditions. However, culture liquid may have pH-gradient due to the activity of cells and change of the environment. In order to confirm the existence of pH-gradient, we propose a method for 3D pH measurement using the color change of phenol red. Using the principle of CT scan, we can measure pH-gradient without contacting culture liquid, and thus, decrease the possibility of contamination. In this paper, we consider the influence of light refraction by a cylindrical vessel, and show that we can measure local pH of culture liquid by light absorbance.Item type:Item, 3D pH MEASUREMENT FOR CELL CULTURE USING CT SCAN(2017-01-01) ;Higashino, Nobuya ;Takayama, Toshio ;Ito, Hiroaki ;Horade, MitsuhiroTsai, Chia-Hung DylanItem type:Item, Inverse Streamline Mapping for Finding an Optimum Medicine Injection Point in Micro Chamber(2018-01-01) ;Takayama, Toshio ;Akai, Takayuki ;Tsai, Chia-Hung Dylan ;Kaneko, Makoto機械工程學系This paper proposes a new concept of "Inverse Streamline Mapping for Finding an Optimum Medicine Injection Point in Micro Chamber". We search the streamlines from the target chamber to the point in the cross-section at the entrance, so that we can find an optimum medicine injection point. The optimum condition is that all streamlines in target chamber start from the smallest cross-sectional area for a given microfluidic chip. The idea is enhanced by designing the microfluidic channel with the desirable streamline mapping between the target chamber and the cross-section at the entrance. We show that the liquid supplied at a particular point can fully cover the chamber in both simulations and experiments.Item type:Item, LED-CT Scan for pH Distribution on a Cross-Section of Cell Culture Medium(2018-01-01) ;Higashino, Nobuya ;Takayama, Toshio ;Ito, Hiroaki ;Horade, MitsuhiroYamaguchi, YasutakaIn cell culture, the pH of the culture medium is one of the most important conditions. However, the culture medium may have non-uniform pH distribution due to activities of cells and changes in the environment. Although it is possible to measure the pH distribution with an existing pH meter using distributed electrodes, the method involves direct contact with the medium and would greatly increase the risk of contamination. Here in this paper, we propose a computed tomography (CT) scan for measuring pH distribution using the color change of phenol red with a light-emitting diode (LED) light source. Using the principle of CT scan, we can measure pH distribution without contacting culture medium, and thus, decrease the risk of contamination. We have developed the device with a LED, an array of photo receivers and a rotation mechanism. The system is firstly calibrated with different shapes of wooden objects that do not pass light, we succeeded in obtaining their 3D topographies. The system was also used for measuring a culture medium with two different pH values, it was possible to obtain a pH distribution that clearly shows the boundary.Item type:Item, On-chip density mixer enhanced by air chamber(2018-07-01) ;Takayama, Toshio ;Miyashiro, Hiroki ;Tsai, Chia-Hung Dylan ;Ito, HiroakiKaneko, MakotoThis paper proposes an on-chip density mixer that can achieve even density in a target chamber with a swirling flow enhanced by an air chamber. The system is composed of a main channel, a target chamber where two liquids with different densities are included, an isolated air chamber, and an external vibration pump driven by a piezo actuator at the entrance of the main channel. The air chamber is expected to amplify the vibration owing to structure softening. The amplification would be more pronounced at the resonance frequencies of the structure. We developed the system and conducted experiments. We showed that the swirling motion in the target chamber with an air chamber is stronger than that without an air chamber. We also confirmed that the time resulting in even density is shorter when the pump is driven at a resonance frequency. An air-based virtual valve is introduced for maintaining a constant density in the target chamber. Published by AIP Publishing.Item type:Item, On-Chip Virtual Vortex Gear and Its Application(2018-01-01) ;Takayama, Toshio ;Tsai, Chia-Hung Dylan ;Kaneko, Makoto ;機械工程學系Department of Mechanical EngineeringItem type:Item, Simultaneous observation of cell behavior on multiple substrates with different heights(2017-01-01) ;Taniguchi, Tsukasa ;Horade, Mitsuhiro ;Ito, Hiroaki ;Takayama, ToshioTsai, Chia-Hung DylanWe propose a microscopic system that can perform simultaneous time-lapse recordings for studying cell behavior on different substrates. The microscopic objective lens is controlled up and down so that the focal plane is matched with different heights of each surface. The captured video includes two types of images with a given time interval. Later, the focused image corresponding to each substrate is rearranged every time segment. To confirm the working principle, we show the experimental results for smooth muscle cells (SMCs) by using two different substrates.Item type:Item, Simultaneous observation of cell behavior on multiple substrates with different heights(2017-01-01) ;Taniguchi, Tsukasa ;Horade, Mitsuhiro ;Ito, Hiroaki ;Takayama, ToshioTsai, Chia-Hung DylanItem type:Item, VIBRATION BASED VIRTUAL VORTEX GEAR(2018-01-01) ;Miyashiro, Hiroki ;Takayama, Toshio ;Tsai, Chia-Hung Dylan ;Kaneko, Makoto機械工程學系This paper proposes Vibration based Virtual Vortex Gear (V(3)G) that can eventually produce a vortex flow in a micro chamber by pressure vibration. An interesting observation is that a vortex flow can be induced under V(3)G without continuous fluid flow in or out at the entrance of chamber, while it is completely different from our previously discovered Virtual Vortex Gear (V(2)G) where we apply a continuous fluid flow. The experiments have been performed to support the idea. Furthermore, we find that the characteristics of V(3)G is enhanced with an additional air chamber.Item type:Item, Virtual vortex gear: Unique flow patterns driven by microfluidic inertia leading to pinpoint injection(2018-05-01) ;Tsai, Chia-Hung Dylan ;Takayama, Toshio ;Shimozyo, Yuta ;Akai, TakayukiKaneko, MakotoAn interesting phenomenon that vortices are sequentially generated on a microfluidic chip is investigated in this paper. The direction of every two adjacent vortices is opposite to each other, like a set of gears, and thus is named virtual vortex gear (VVG). Both experiments and computational simulations were conducted in order to make clear the mechanism of VVG. The experimental results show that only the flow from a particular point would form vortices and enter the target chamber. A technique of inverse mapping is proposed based on the phenomenon and it demonstrates that only a pinpoint injection is sufficient to control the contents of a microfluidic chamber. VVG can significantly reduce the volume of chemical usage in biological research and has potential for other on-chip applications, such as mixing and valving. Published by AIP Publishing.