Browsing by Author "Tarng, Der-Cherng"
Now showing 1 - 8 of 8
- Results Per Page
- Sort Options
Item type:Item, A Novel Wireless Photoplethysmography Blood-Flow Volume Sensor for Assessing Arteriovenous Fistula of Hemodialysis Patients(2017-12-01) ;Chiang, Pei-Yu ;Chao, Paul C. -P. ;Tarng, Der-Cherng ;Yang, Chih-Yu電控工程研究所A novel blood-flow volume (BFV) sensor is presented for assessing quality of arteriovenous fistula in hemodialysis patients via noninvasive reflectance-type photoplethysmography (PPG). BFV is nowadays in clinic practices evaluated using an ultrasound Doppler monitor, which is expensive, bulky, and can only be operated by well-trained medical personnels. This study is devoted to develop a low-cost, small-sized, portable, and easy-to-use PPG sensor that is capable of continuous measurement of BFV. New designs of front-end analog circuits, signal processing, and an intelligent neural network calibration method are employed to finally achieve high correlation (R-2 = 0.7176), as opposed to the ultrasound Doppler monitor, with the root-mean-squared errors successfully controlled under 289 ml/min.Item type:Item, A Portable, Wireless Photoplethysomography Sensor for Assessing Health of Arteriovenous Fistula Using Class-Weighted Support Vector Machine(2018-11-01) ;Chao, Paul C. -P. ;Chiang, Pei-Yu ;Kao, Yung-Hua ;Tu, Tse-YiYang, Chih-YuA portable, wireless photoplethysomography (PPG) sensor for assessing arteriovenous fistula (AVF) by using class-weighted support vector machines (SVM) was presented in this study. Nowadays, in hospital, AVF are assessed by ultrasound Doppler machines, which are bulky, expensive, complicated-to-operate, and time-consuming. In this study, new PPG sensors were proposed and developed successfully to provide portable and inexpensive solutions for AVF assessments. To develop the sensor, at first, by combining the dimensionless number analysis and the optical Beer Lambert's law, five input features were derived for the SVM classifier. In the next step, to increase the signal-noise ratio (SNR) of PPG signals, the front-end readout circuitries were designed to fully use the dynamic range of analog-digital converter (ADC) by controlling the circuitries gain and the light intensity of light emitted diode (LED). Digital signal processing algorithms were proposed next to check and fix signal anomalies. Finally, the class-weighted SVM classifiers employed five different kernel functions to assess AVF quality. The assessment results were provided to doctors for diagonosis and detemining ensuing proper treatments. The experimental results showed that the proposed PPG sensors successfully achieved an accuracy of 89.11% in assessing health of AVF and with a type II error of only 9.59%.Item type:Item, Machine Learning Classification for Assessing the Degree of Stenosis and Blood Flow Volume at Arteriovenous Fistulas of Hemodialysis Patients Using a New Photoplethysmography Sensor Device(2019-08-01) ;Chiang, Pei-Yu ;Chao, Paul C. -P. ;Tu, Tse-Yi ;Kao, Yung-HuaYang, Chih-YuThe classifier of support vector machine (SVM) learning for assessing the quality of arteriovenous fistulae (AVFs) in hemodialysis (HD) patients using a new photoplethysmography (PPG) sensor device is presented in this work. In clinical practice, there are two important indices for assessing the quality of AVF: the blood flow volume (BFV) and the degree of stenosis (DOS). In hospitals, the BFV and DOS of AVFs are nowadays assessed using an ultrasound Doppler machine, which is bulky, expensive, hard to use, and time consuming. In this study, a newly-developed PPG sensor device was utilized to provide patients and doctors with an inexpensive and small-sized solution for ubiquitous AVF assessment. The readout in this sensor was custom-designed to increase the signal-to-noise ratio (SNR) and reduce the environment interference via maximizing successfully the full dynamic range of measured PPG entering an analog-digital converter (ADC) and effective filtering techniques. With quality PPG measurements obtained, machine learning classifiers including SVM were adopted to assess AVF quality, where the input features are determined based on optical Beer-Lambert's law and hemodynamic model, to ensure all the necessary features are considered. Finally, the clinical experiment results showed that the proposed PPG sensor device successfully achieved an accuracy of 87.84% based on SVM analysis in assessing DOS at AVF, while an accuracy of 88.61% was achieved for assessing BFV at AVF.Item type:Item, MicroRNA-92a Mediates Endothelial Dysfunction in CKD(2017-11-01) ;Shang, Fenqing ;Wang, Shen-Chih ;Hsu, Chien-Yi ;Miao, YifeiMartin, MarcyCKD is an independent risk factor for cardiovascular disease (CVD). The accumulation of uremic toxins in CKD induces oxidative stress and endothelial dysfunction. MicroRNA-92a (miR-92a) is induced by oxidative stress in endothelial cells (ECs) and involved in angiogenesis and atherosclerosis. We investigated a role for oxidative stress responsive miR-92a in CKD. Our study of patients at three clinical sites showed increased serum miR-92a level with decreased kidney function. In cultured ECs, human CKD serum or uremic toxins (such as indoxyl sulfate), compared with non-CKD serum, induced the levels of miR-92a and suppressed the expression of miR-92a targets, including key endothelial-protective molecules. The antioxidant N-acetylcysteine inhibited these vasculopathic properties. In rats, adenine-induced CKD associated with increased levels of miR-92a in aortas, serum, and CD144(+) endothelial microparticles. Furthermore, CD144(+) microparticles from human uremic serum contained more miR-92a than those from control serum. Additional analysis showed a positive correlation between serum levels of miR-92a and indoxyl sulfate in a cohort of patients with ESRD undergoing hemodialysis. Collectively, our findings suggest that the uremic toxins accumulated in CKD can upregulate miR-92a in ECs, which impairs EC function and predisposes patients to CVD.Item type:Item, The Anastomotic Angle of Hemodialysis Arteriovenous Fistula Is Associated With Flow Disturbance at the Venous Stenosis Location on Angiography(2020-07-23) ;Yang, Chih-Yu ;Li, Ming-Chia ;Lan, Chien-Wen ;Lee, Wang-JiunLee, Chen-JuThe juxta-anastomotic stenosis of an arteriovenous fistula (AVF) is a significant clinical problem in hemodialysis patients with no effective treatment. Previous studies of AV anastomotic angles on hemodynamics and vascular wall injury were based on computational fluid dynamics (CFD) simulations using standardized AVF geometry, not the real-world patient images. The present study is the first CFD study to use angiographic images with patient-specific outcome information, i.e., the exact location of the AVF stenotic lesion. We conducted the CFD analysis utilizing patient-specific AVF geometric models to investigate hemodynamic parameters at different locations of an AVF, and the association between hemodynamic parameters and the anastomotic angle, particularly at the stenotic location. We analyzed 27 patients who used radio-cephalic AVF for hemodialysis and received an angiographic examination for juxta-anastomotic stenosis. The three-dimensional geometrical model of each patient's AVF was built using the angiographic images, in which the shape and the anastomotic angle of the AVF were depicted. CFD simulations of AVF hemodynamics were conducted to obtain blood flow parameters at different locations of an AVF. We found that at the location of the stenotic lesion, the AV angle was significantly correlated with access flow disturbance (r= 0.739;p< 0.001) and flow velocity (r= 0.563;p= 0.002). Furthermore, the receiver operating characteristic (ROC) curve analysis revealed that the AV angle determines the lesion's flow disturbance with a high area under the curve value of 0.878. The ROC analysis also identified a cut-off value of the AV angle as 46.5 degrees, above or below which the access flow disturbance was significantly different. By applying CFD analysis to real-world patient images, the present study provides evidence that an anastomotic angle wider than 46.5 degrees might lead to disturbed flow generation, demonstrating a reference angle to adopt during the anastomosis surgery.Item type:Item, Theoretical developments and clinical experiments of measuring blood flow volume (BFV) at arteriovenous fistula (AVF) using a photoplethysmography (PPG) sensor(2018-11-01) ;Chiang, Pei-Yu ;Chao, Paul C. -P. ;Yang, Chih-Yu ;Tarng, Der-Cherng電子工程學系及電子研究所A new theoretical developments of measuring blood flow volume at arteriovenous fistula (AVF) using a photoplethysmography (PPG) sensor is presented in this work. The mathematical equation is derived under the practical perspective, aiming at applying to small-size, portable, inexpensive and easy-to-use PPG sensor, in order to replace bulky, expensive Doppler machines which is the commonly used instruments for accessing AVF noninvasively nowadays. Furthermore, a new, portable and wireless PPG sensor with ambient light compensation and motion artifact detection, is designed for performing clinical validation of the proposed equation. After neural network calibration with the gold standard, dilution concentration sensor, the experiment result reveals that the PPG sensors implementing the proposed equation successfully achieve much higher correlation (R-2=0.8064) and much lower error (RMSE=171.68ml/min, MAPE=15.84%) compared to the commercial Doppler machine and other previous works.Item type:Item, Trichostatin A Alleviates Renal Interstitial Fibrosis Through Modulation of the M2 Macrophage Subpopulation(2020-09-01) ;Tseng, Wei-Cheng ;Tsai, Ming-Tsun ;Chen, Nien-Jung ;Tarng, Der-Cherng交大名義發表Mounting evidence indicates that an increase in histone deacetylation contributes to renal fibrosis. Although inhibition of histone deacetylase (HDAC) can reduce the extent of fibrosis, whether HDAC inhibitors exert the antifibrotic effect through modulating the phenotypes of macrophages, the key regulator of renal fibrosis, remains unknown. Moreover, the functional roles of the M2 macrophage subpopulation in fibrotic kidney diseases remain incompletely understood. Herein, we investigated the role of HDAC inhibitors on renal fibrogenesis and macrophage plasticity. We found that HDAC inhibition by trichostatin A (TSA) reduced the accumulation of interstitial macrophages, suppressed the activation of myofibroblasts and attenuated the extent of fibrosis in obstructive nephropathy. Moreover, TSA inhibited M1 macrophages and augmented M2 macrophage infiltration in fibrotic kidney tissue. Interestingly, TSA preferentially upregulated M2c macrophages and suppressed M2a macrophages in the obstructed kidneys, which was correlated with a reduction of interstitial fibrosis. TSA also repressed the expression of proinflammatory and profibrotic molecules in cultured M2a macrophages and inhibited the activation of renal myofibroblasts. In conclusion, our study was the first to show that HDAC inhibition by TSA alleviates renal fibrosis in obstructed kidneys through facilitating an M1 to M2c macrophage transition.Item type:Item, Tubular transcriptional co-activator with PDZ-binding motif protects against ischemic acute kidney injury(2020-07-01) ;Wu, Chia-Lin ;Chang, Chia-Chu ;Yang, Tao-Hsiang ;Tsai, Alexander Charng-DarWang, Jui-LinTranscriptional co-activator with PDZ-binding motif (TAZ) is a key downstream effector of the Hippo tumor-suppressor pathway. The functions of TAZ in the kidney, especially in tubular epithelial cells, are not well-known. To elucidate the adaptive expression, protective effects on kidney injury, and signaling pathways of TAZ in response to acute kidney injury (AKI), we used in vitro (hypoxia-treated human renal proximal tubular epithelial cells [RPTECs]) and in vivo (mouse ischemia-reperfusion injury [IRI]) models of ischemic AKI. After ischemic AKI, TAZ was up-regulated in RPTECs and the renal cortex or tubules. Up-regulation of TAZ in RPTECs subjected to hypoxia was controlled by I kappa B kinase (IKK)/nuclear factor kappa-light-chain-enhancer of activated B cell (NF-kappa B) signaling. TAZ overexpression attenuated hypoxic and oxidative injury, inhibited apoptosis and activation of p38 and c-Jun N-terminal kinase (JNK) proteins, and promoted wound healing in an RPTEC monolayer. However, TAZ knockdown aggravated hypoxic injury, apoptosis, and activation of p38 and JNK signaling, delayed wound closure of an RPTEC monolayer, and promoted G(0)/G(1) phase cell-cycle arrest. Chloroquine and verteporfin treatment produced similar results to TAZ overexpression and knockdown in RPTECs, respectively. Compared with vehicle-treated mice, chloroquine treatment increased TAZ in the renal cortex and tubules, improved renal function, and attenuated tubular injury and tubular apoptosis after renal IRI, whereas TAZ siRNA and verteporfin decreased TAZ in the renal cortex and tubules, deteriorated renal failure and tubular injury, and aggravated tubular apoptosis. Our findings indicate the renoprotective role of tubular TAZ in ischemic AKI. Drugs augmenting (e.g., chloroquine) or suppressing (e.g., verteporfin) TAZ in the kidney might be beneficial or deleterious to patients with AKI.