Browsing by Author "Tseng, Yuhwai"
Now showing 1 - 6 of 6
- Results Per Page
- Sort Options
Item type:Item, A 0.09 mu W Low Power Front-End Biopotential Amplifier for Biosignal Recording(2012-10-01) ;Tseng, Yuhwai ;Ho, Yingchieh ;Kao, Shuoting ;Su, Chauchin電子工程學系及電子研究所This work presents a biopotential front-end amplifier in which the MOS transistors are biased in subthreshold region with a supply voltage and current of 0.4-0.8 V and 0.23-1.86 mu A, respectively, to reduce the system power. Flicker noise is then removed using a chopping technique, and differential interference produced by electrode impedance imbalance is suppressed using a Gm-C filter. Additionally, the circuit is fabricated using TSMC 0.18 mu m CMOS technology with a core area of 0.77 X 0.36 mm(2). With a minimum supply voltage of 0.4 V, the measured SNR and power consumption of the proposed IC chip are 54.1 dB and 0.09 mu W, respectively.Item type:Item, A 0.5V/22 mu W Low Power Transceiver IC for Use in FSC Intra-body Communication System(2016) ;Tseng, Yuhwai ;Lin, Tinyou ;Yau, Songwen ;Ho, YingchiehSu, ChauchinThis paper presents an integrated transciver chip for use in electro-static coupling intra body communication. A simplified circuit model was developed to analyze the channel characteristics. A Manchester code was used to increase signal energy. In front of the receiver, an inverter-based amplifier applies to amplify the received data. Then, a Clock and Data Recovery data develops to recover the transmitted data. The chip is fabricated using UMC 0.18um CMOS process with a chip area of 0.75 X 0.7 mm(2), power consumption of 22uW and a data transmission rate of 10M bit per second.Item type:Item, Analysis and Design of Wide-Band Digital Transmission in an Electrostatic-Coupling Intra-Body Communication System(2009-11-01) ;Tseng, Yuhwai ;Su, Chauchin ;Liu, Chien-Nan Jimmy ;電控工程研究所Institute of Electrical and Control EngineeringThis study develops a form of digital baseband Intra-Body communication for wideband transmission. A simplified circuit model of signal and noise is constructed to analyze the contribution of the high pass filter function of the electrostatic coupling Intra-Body communication system to wideband digital transmission in electrostatic coupling Intra-Body communication. A unit step function is presented to determine the maximum high pass 3 dB pole that can ensure favorable signal quality in a baseband Intra-Body communication system. Body noise is measured to estimate the range of the high pass 3dB pole with good Signal to Noise Ratio. A 3.3 Volt battery-powered FPGA is experimentally implemented to confirm the feasibility of the wideband Intra-Body communication system. The experimental results indicate that the digital baseband Intra-Body communication system supports a data rate of more than 16MPS.Item type:Item, Evaluation and Verification of Channel Transmission Characteristics of Human Body for Optimizing Data Transmission Rate in Electrostatic-Coupling Intra Body Communication System: A Comparative Analysis(2016-02-11) ;Tseng, Yuhwai ;Su, Chauchin ;Ho, Yingchieh ;電控工程研究所Institute of Electrical and Control EngineeringBackground Intra-body communication is a new wireless scheme for transmitting signals through the human body. Understanding the transmission characteristics of the human body is therefore becoming increasingly important. Electrostatic-coupling intra-body communication system in a ground-free situation that integrate electronic products that are discretely located on individuals, such as mobile phones, PDAs, wearable computers, and biomedical sensors, are of particular interest. Materials and Methods The human body is modeled as a simplified Resistor-Capacitor network. A virtual ground between the transmitter and receiver in the system is represented by a resister-capacitor network. Value of its resistance and capacitance are determined from a system perspective. The system is characterized by using a mathematical unit step function in digital baseband transmission scheme with and without Manchester code. As a result, the signal-to-noise and to-intersymbol-interference ratios are improved by manipulating the load resistor. The data transmission rate of the system is optimized. A battery-powered transmitter and receiver are developed to validate the proposal. Results A ground-free system fade signal energy especially for a low-frequency signal limited system transmission rate. The system transmission rate is maximized by simply manipulating the load resistor. Experimental results demonstrate that for a load resistance of 10k-50k Omega, the high-pass 3 dB frequency of the band-pass channel is 400kHz-2MHz in the worst-case scenario. The system allows a Manchester-coded baseband signal to be transmitted at speeds of up to 20M bit per second with signal-to-noise and signal-to-intersymbol-interference ratio of more than 10 dB. Conclusion The human body can function as a high speed transmission medium with a data transmission rate of 20Mbps in an electrostatic-coupling intra-body communication system. Therefore, a wideband signal can be transmitted directly through the human body with a good signal-to-noise quality of 10 dB if the high-pass 3 dB frequency is suitably selected.Item type:Item, Measurement and Evaluation of the Bioelectrical Impedance of the Human Body by Deconvolution of a Square Wave(2010-06-01) ;Tseng, Yuhwai ;Su, Chauchin ;Liu, Chien-Nan Jimmy ;電控工程研究所Institute of Electrical and Control EngineeringIn this study, we use the deconvolution of a square test stimulus to replace a series of sinusoidal test waveforms with different frequencies to simplify the measurement of human body impedance. The average biological impedance of body parts is evaluated by constructing a frequency response of the equivalent human body system. Only two stainless-steel electrodes are employed in the measurement and evaluation.Item type:Item, Measuring the Transmission Characteristic of the Human Body in an Electrostatic-Coupling Intra Body Communication System Using a Square Test Stimulus(2010-03-01) ;Tseng, Yuhwai ;Su, Chauchin ;Liu, Chien-Nan Jimmy ;電控工程研究所Institute of Electrical and Control EngineeringThis study employs a simple measurement methodology that is based on the de-convolution of a square test stimulus to measure the transmission characteristics of the human body channel in an electrostatic-coupling intra body communication system. A battery-powered square waveform generator was developed to mimic the electrostatic-coupling intra body communication system operating in the environment of the ground free. The measurement results are then confirmed using a reliable measuring method (single tone) and spectral analysis. The results demonstrate that the proposed measurement approach is valid for up to 32.5 MHz, providing a data rate of over 16 Mbps.