S-parameters-based high speed signal characterization of Al and Cu interconnect on low-K hydrogen silsesquioxane-Si substrate
Loading...
Date
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
DOI
Abstract
In this study, hydrogen silsesquioxane (HSQ) thin films are employed as the intermetal dielectric, and the high frequency characteristics of Al-HSQ and Cu/Ta-HSQ system are investigated and compared with those of Al-SiO2 system. The S-parameters of the interconnect are measured for insertion loss and crosstalk noise. The interconnect transmission parameters are extracted from the S-parameters. A figure of merit (FOM) is employed to evaluate the characteristics of the interconnect system at high frequencies (100MHz similar to 20GHz). It is found that the insertion losses are 2.01dB/mm, and 1.50dB/mm, 2.73dB/mm, 2.44dB/mm, and 1.66dB/mm at 10GHz, and 2.16dB/mm, 1.64dB/mm, 3.08dB/mm, 2.62dB/mm, and 1.82dB/mm at 20GHz for Al-SiO2, Al-HSQ, Al-HSQ (02 plasma), Cu/Ta-HSQ, and Cu/Ta-HSQ (NH3 plasma), respectively. The Al/HSQ system has better performance than the other ones do from 100MHz to 20GHz. The high frequency characteristics of Al and Cu interconnect with HSQ dielectrics are discussed.