A Reliable Brain Computer Interface Implemented On FPGA For Mobile Dialing System
Loading...
Date
Journal Title
Journal ISSN
Volume Title
Publisher
DOI
Abstract
This paper demonstrates a high performance brain-computer interface (BCI) that allows users to dial phone numbers. The system is based on Canonical Correlation Analysis (CCA) and Steady-State Visual Evoked Potential (SSVEP). Through six buttons (9Hz, 10Hz, 11Hz, 12Hz, 13 Hz, 14Hz) displayed on the screen, subjects can choose the number by gazing at the computer interface. This proposed EEG (Electroencephalography) system has been implemented in Field-Programmable Gate Arrays (FPGA) and it features high accuracy, integration density, and low cost. These features are meaningful for implementing a real time SSVEP-based BCI.