<link rel="stylesheet" href="styles.cf390c6bfbe7555f.css"> Skip to main content

學術出版;;Publications

Permanent URI for this communityhdl:11536/1

收集所有交通大學研究人員與學生個人或團體所發表之各項學術著作,涵蓋期刊論文、教師專書、學位論文等項。;;Collections of Publications of NCTU Researchers and Students Like Journal Papers and Thesis.

Browse

🏛️國立陽明交通大學機構典藏

Search Results

Now showing 1 - 2 of 2
  • Item type:Item,
    Low-voltage GaInP/GaAs HBT wideband Gilbert downconverter using transformer RF balun
    (2007)
    Tseng, Sheng-Che
    ;
    Meng, Chinchun
    ;
    Wu, Chih-Kai
    ;
    Huang, Guo-Wei
    ;
    電信工程研究所
    This paper demonstrates a low-voltage wideband downconverter along with an integrated transformer RF balun using the 2-mu m GaInP/GaAs HBT technology. This transformer is a symmetric type and plays a role as a single-to-differential balun. Without the parasitics between the transformer and the substrate, the transformer can work at higher frequencies. This transformer downconverter operates from 1.5 GHz to 14 GHz with around 20-dB conversion gain and 1.8-GHz IF 3-dB bandwidth. The frequency range of the mixing operation is wide and covers the digital video broadcasting via satellite (DVB-S) bands. This mixer hence is useful for DVB-S applications. Since there is no dc voltage drop on the transformer, the voltage supply of the mixer core is only 2.4 V and the current consumption is approximately 8.6 mA. The chip size of the entire mixer is 1 mm x 1 mm while the transformer occupies the estate of 150 mu m x 150 mu m.
  • Item type:Item,
    SiGe HBT Gilbert downconverter with an integrated miniaturized Marchand balun for UWB applications
    (2007)
    Tseng, Sheng-Che
    ;
    Meng, Chinchun
    ;
    Chang, Chia-Hung
    ;
    Huang, Guo-Wei
    ;
    電信工程研究所
    A 15.5-dB conversion gain 0.35-mu m SiGe HBT Gilbert mixer with the lumped-element Marchand balun for 3.1 GHz to 10.6 GHz UWB applications is implemented using standard silicon processes. This mixer has the 1.5-GHz IF 3-dB bandwidth as well as the 15.8-dB noise figure. The balun size is only 0.25 mm x 0.5 mm. Because of the balanced structure of the Marchand balun, the magnitude imbalance and phase difference of outputs are below 1 dB and about 184 degrees, respectively. In the present of a lossy substrate, the dissipated loss of the balun is still less than 4 dB thanks to the advantage of the lumped-element technique. The total current consumption of the entire mixer is 13.9 mA at 5 V voltage supply while the chip size including probing pads is 1 mm x 0.9 mm.