    Non-Uniform Three-Dimensional Pulsating Heat Pipe for Anti-Gravity High-Flux Applications
    (2020-06-01)
    Tseng, Chih-Yung
    ;
    Yang, Kai-Shing
    ;
    Wang, Chi-Chuan
    ;
    交大名義發表
    ;
    National Chiao Tung University
    This study proposes a novel high-flux pulsating heat pipe that can lift the major constraint of the conventional pulsating heat pipe (PHP) which is unable to function properly upon anti-gravity operations. The proposed PHP introduces additional unbalance force via uneven tube diameter/geometry in the adiabatic sections to tailor the problem in anti-gravity operation. The design contains a three-dimensional configuration circuitry with compact arrangement tubes on the evaporator and condenser. Through this design, the non-uniform three-dimensional pulsating heat pipe (3D-PHP) manipulates the uneven inner diameters of the adiabatic sections to form uneven vapor/liquid distributions in the adiabatic sections to yield a unitary flow pattern that is able to withstand a much higher input power. The present PHP uses methanol as working fluid, with 38% volumetric filling ratio, and has a high-flux of 22.9 W/cm(2)and a low the thermal resistance ratio (Ranti-gravity/Rgravity-assisted) of 1.05 when the input power is 800 W. Both the heat flux and thermal resistance ratio for the proposed design are far better than the existing literature.
  • Item type:Item,
    A novel "partial bypass" concept to augment the performance of air-cooled heat exchangers
    (2012-09-01)
    Wang, Chi-Chuan
    ;
    Chen, Kuan-Yu
    ;
    Liaw, Jane-Sunn
    ;
    Tseng, Chih-Yung
    ;
    機械工程學系
    This study proposes a novel "partial bypass" concept which facilitates the heat transfer augmentation without the pumping power penalty. The basic idea is to introduce bypass cold stream which bypasses the front part of the heat exchanger and mixes with the hot stream across the front part of the heat exchanger, and the mixed stream flows through the rear part of the heat exchanger. Through this concept, heat transfer performance at the front part is slightly reduced but the rear part is substantially increased. The concept can be implemented with either maintaining the same total flowrate, heat transfer rate but accompanies with a much lower pressure drop or it can be applied with the same pumping power but accompanies with a much higher heat transfer rate. It is found that the "partial bypass" concept is especially fruitful for a heat exchanger with a comparatively large number of transfer unit (NTU). The concept is especially helpful in the design of a deep tube bank operated at lower frontal velocity. For validating the proposed concept, the calculation is also compared with the experimental measurements, and good agreement amid the calculations and measurements are reported. (C) 2012 Elsevier Ltd. All rights reserved.
  • Item type:Item,
    Investigation of the evacuation pressure on the performance of pulsating heat pipe
    (2017-07-01)
    Sun, Chien-Hung
    ;
    Tseng, Chih-Yung
    ;
    Yang, Kai-Shing
    ;
    Wu, Shih-Kuo
    ;
    Wang, Chi-Chuan
    This study examines the influence of evacuation pressure on the startup and overall performance of pulsating heat pipes (PHP). The outer diameter of the copper tube is 3 mm and 2 mm (double tube design) having a wall thickness of 0.3 mm and 0.2 mm, respectively. The working fluids in this study include water and HFE-7000 with filling ratios around 50%, and the evacuation pressure ranging from 0.01 Torr to atmosphere pressure. For an evacuation pressure of 0.01 Torr at a supplied power of 80 W, the thermal resistance of the PHP filling with water is 0.928 K/W while it is 1.161 K/W for HFE-7000. However, the trend is reversed and the thermal resistance for HFE-7000 is lower than water when the evacuation pressure is increased over 100 Torr. The corresponding effective thermal conductivity of waterfilling PHP reaches 51,448 W/m K in comparison with 12,692 W/m K for HFE-7000. However, the effective thermal conductivity for waterfilling PHP drops appreciably with rising evacuation pressure, and the PHP is not functional at the atmosphere pressure. Conversely, although the effective thermal conductivity for HFE-7000 PHP still drops with the rise of evacuation pressure, the HFE-7000 PHP is still in operation even without any evacuation. The gigantic difference in the startup and performance of PHP is related to the solubility of noncondensable gas amid water and HFE-7000.
  • Item type:Item,
    A novel double pipe pulsating heat pipe design to tackle inverted heat source arrangement
    (2016-08-05)
    Tseng, Chih-Yung
    ;
    Yang, Kai-Shing
    ;
    Chien, Kuo-Hsiang
    ;
    Wu, Shih-Kuo
    ;
    Wang, Chi-Chuan
    Traditional pulsating heat pipe with fewer turns is functional only when the heat source is placed at the bottom while the heat sink is on top. This study proposes a novel design having alternative double-pipe tube diameter with some extra open connections of these double-pipes. By introducing extra un-balanced pressure force, capillary force and gravity force, the PHP can be easily starting up even for an opposite heat source/sink arrangement while the conventional single tube design fails to start up with this opposite arrangement. The thermal resistance of double pipe PHP can be lowered to 0.0729 W/K with an effective thermal conductivity of 12,603 W/m.K when the heat source is placed on top. Yet the thermal resistance for the proposed double pipe design is only half of the single tube design. (C) 2016 Elsevier Ltd. All rights reserved.
  • Item type:Item,
    An experimental study of the air-side performance of fin-and-tube heat exchangers having plain, louver, and semi-dimple vortex generator configuration
    (2015-01-01)
    Wang, Chi-Chuan
    ;
    Chen, Kuan-Yu
    ;
    Liaw, Jane-Sunn
    ;
    Tseng, Chih-Yung
    ;
    機械工程學系
    In this study, a comparative study of the airside performance of fin-and-tube heat exchangers having plain, louver, and semi-dimple vortex generator (VG) are made. A total of eighteen samples are made and tested with the corresponding fin pitch (F-p) being 1.6 mm and 2.0 mm and the number of tube row (N) are 1, 2 and 4, respectively. Test results indicate that the heat transfer coefficient for N = 1 for louver fin geometry with a smaller fin pitch of 1.6 mm is higher than that of semi-dimple VG and plain fin geometry. For N = 1 with a larger fin pitch of 2.0 mm, the semi-dimple VG is marginally higher than that of louver fin geometry when the frontal velocity is lower than 2 m s(-1). However, the trend is reversed where the heat transfer coefficient for louver fin outperforms that of semi-dimple VG when the velocity is increased further. For the airside performance for N = 2 or N = 4, the heat transfer coefficients for louver fin geometry is about 2-15% higher than those of semi-dimple geometry. The difference is increased with the rising velocity and the results prevail for both fin pitches. However, the difference is smaller at a larger fin pitch due to the comparatively effectively swirled motion of the semi-dimple VG. The effect of the number of tube row on the heat transfer coefficients is negligible for louver fin geometry and is also rather small for semi-dimple VG. For the plain fin geometry, the effect of tube row is also small when N > 1. The heat transfer performance for N = 1 is different from N = 2 or N = 4 due to its inline configuration. (C) 2014 Elsevier Ltd. All rights reserved.
  • Item type:Item,
    "A novel ""partial bypass"" concept to augment the performance of air-cooled heat exchangers"
    (2012-09-01)
    Wang, Chi-Chuan
    ;
    Chen, Kuan-Yu
    ;
    Liaw, Jane-Sunn
    ;
    Tseng, Chih-Yung
    ;
    機械工程學系
    "This study proposes a novel ""partial bypass"" concept which facilitates the heat transfer augmentation without the pumping power penalty. The basic idea is to introduce bypass cold stream which bypasses the front part of the heat exchanger and mixes with the hot stream across the front part of the heat exchanger, and the mixed stream flows through the rear part of the heat exchanger. Through this concept, heat transfer performance at the front part is slightly reduced but the rear part is substantially increased. The concept can be implemented with either maintaining the same total flowrate, heat transfer rate but accompanies with a much lower pressure drop or it can be applied with the same pumping power but accompanies with a much higher heat transfer rate. It is found that the ""partial bypass"" concept is especially fruitful for a heat exchanger with a comparatively large number of transfer unit (NTU). The concept is especially helpful in the design of a deep tube bank operated at lower frontal velocity. For validating the proposed concept, the calculation is also compared with the experimental measurements, and good agreement amid the calculations and measurements are reported. (C) 2012 Elsevier Ltd. All rights reserved."