    Investigation of the evacuation pressure on the performance of pulsating heat pipe
    (2017-07-01)
    Sun, Chien-Hung
    ;
    Tseng, Chih-Yung
    ;
    Yang, Kai-Shing
    ;
    Wu, Shih-Kuo
    ;
    Wang, Chi-Chuan
    This study examines the influence of evacuation pressure on the startup and overall performance of pulsating heat pipes (PHP). The outer diameter of the copper tube is 3 mm and 2 mm (double tube design) having a wall thickness of 0.3 mm and 0.2 mm, respectively. The working fluids in this study include water and HFE-7000 with filling ratios around 50%, and the evacuation pressure ranging from 0.01 Torr to atmosphere pressure. For an evacuation pressure of 0.01 Torr at a supplied power of 80 W, the thermal resistance of the PHP filling with water is 0.928 K/W while it is 1.161 K/W for HFE-7000. However, the trend is reversed and the thermal resistance for HFE-7000 is lower than water when the evacuation pressure is increased over 100 Torr. The corresponding effective thermal conductivity of waterfilling PHP reaches 51,448 W/m K in comparison with 12,692 W/m K for HFE-7000. However, the effective thermal conductivity for waterfilling PHP drops appreciably with rising evacuation pressure, and the PHP is not functional at the atmosphere pressure. Conversely, although the effective thermal conductivity for HFE-7000 PHP still drops with the rise of evacuation pressure, the HFE-7000 PHP is still in operation even without any evacuation. The gigantic difference in the startup and performance of PHP is related to the solubility of noncondensable gas amid water and HFE-7000.
  • Item type:Item,
    A novel double pipe pulsating heat pipe design to tackle inverted heat source arrangement
    (2016-08-05)
    Tseng, Chih-Yung
    ;
    Yang, Kai-Shing
    ;
    Chien, Kuo-Hsiang
    ;
    Wu, Shih-Kuo
    ;
    Wang, Chi-Chuan
    Traditional pulsating heat pipe with fewer turns is functional only when the heat source is placed at the bottom while the heat sink is on top. This study proposes a novel design having alternative double-pipe tube diameter with some extra open connections of these double-pipes. By introducing extra un-balanced pressure force, capillary force and gravity force, the PHP can be easily starting up even for an opposite heat source/sink arrangement while the conventional single tube design fails to start up with this opposite arrangement. The thermal resistance of double pipe PHP can be lowered to 0.0729 W/K with an effective thermal conductivity of 12,603 W/m.K when the heat source is placed on top. Yet the thermal resistance for the proposed double pipe design is only half of the single tube design. (C) 2016 Elsevier Ltd. All rights reserved.
  • Item type:Item,
    Investigation of the performance of pulsating heat pipe subject to uniform/alternating tube diameters
    (2014-04-01)
    Tseng, Chih-Yung
    ;
    Yang, Kai-Shing
    ;
    Chien, Kuo-Hsiang
    ;
    Jeng, Ming-Shan
    ;
    Wang, Chi-Chuan
    The present study examines the performance of closed-loop pulsating heat pipes (CLPHPs) with an ID of 2.4 mm. The effect of uniform and alternating tube diameter on the performance is investigated. The working fluids include distilled water, methanol and HFE-7100. Tests are performed with both horizontal and vertical arrangement. For the horizontal arrangement, when compared to uniform design, the alternating channel design can be started at a rather low heat input with a much smaller thermal resistance. Normally the thermal resistance is decreased with the rise of heat input, and reveals a minimum value at a certain heat input followed by shows a marginal rise when the heat input is increased further. Both uniform and alternating design reveals the similar trend. For the vertical arrangement, the thermal resistance is much lower than that in horizontal arrangement. Different from that in horizontal arrangement, the thermal resistance shows a continuous decline against heat input for all the working fluids. For a low input power, CLPHP with HFE-7100 shows the least thermal resistance. By contrast, CLPHP with distilled water shows the smallest thermal resistance when the input power is increased over 60 W. (C) 2014 Elsevier Inc. All rights reserved.
  • Item type:Item,
    A novel design of pulsating heat pipe with fewer turns applicable to all orientations
    (2012-10-01)
    Chien, Kuo-Hsiang
    ;
    Lin, Yur-Tsai
    ;
    Chen, Yi-Rong
    ;
    Yang, Kai-Shing
    ;
    Wang, Chi-Chuan
    This study presents a novel pulsating heat pipe (PHP) concept that is functional even when PHP is with fewer turns and is operated horizontally. Two heat pipes were made of copper capillary tubes with an overall size of 122 mm x 57 mm x 5.5 mm is investigated, one had 16 parallel square channels having a uniform cross-section of 2 mm x 2 mm (uniform CLPHP), and the other had 16 alternative size of parallel square channels (non-uniform CLPHP; a cross-section 2 mm x 2 mm and a cross-section of 1 mm x 2 mm in alternating sequence). Test results showed that the performance of PHP rises with the inclination but the uniform channel CLPHP is not functional at horizontal configuration whereas the proposed non-uniform design is still functional even at horizontal arrangement. The thermal resistance for uniform PHP is relative insensitive to change of inclination when the inclination angle exceeds certain threshold value. (c) 2012 Elsevier Ltd. All rights reserved.