標題: | Performance evaluation of steel reduced flange plate moment connections |
作者: | Chou, Chung-Che Wu, Chia-Ching 土木工程學系 Department of Civil Engineering |
關鍵字: | reduced flange plate moment connection;cyclic test;finite element analysis;nonlinear regression analysis;buckling |
公開日期: | 1-Nov-2007 |
摘要: | This study details a new moment connection that overcomes difficulties in achieving field-weld quality and eliminates steel beam buckling encountered in steel moment connections. This study presents cyclic test and finite element analysis results of full-scale subassemblies using steel reduced flange plates (RFPs) to connect steel beam flanges and the column without any other direct connection. Since the RFP connection is designed as strong column-strong beam-weak RFPs, the RFP functions as a structural fuse that eliminates weld fractures and beam buckling. Test and analytical results show that (1) the connections transferred the entire beam flexural strength to the column and reached an interstorey drift of 4% with minor strength degradation, (2) failure of the connections was owing to buckling or fracturing of the RFP and not of the beam, and (3) the RFP connection subassembly, modelled using the nonlinear finite element computer program ABAQUS, exhibited hysteretic behaviour similar to that of the flange plate (FP) moment connection subassembly. The inelastic buckling force of the RFP was also evaluated by nonlinear regression analyses performed on a nonlinear model that relates buckling force to RFP geometries. Copyright (C) 2007 John Wiley & Sons, Ltd. |
URI: | http://dx.doi.org/10.1002/eqe.714 http://hdl.handle.net/11536/10162 |
ISSN: | 0098-8847 |
DOI: | 10.1002/eqe.714 |
期刊: | EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS |
Volume: | 36 |
Issue: | 14 |
起始頁: | 2083 |
結束頁: | 2097 |
Appears in Collections: | Articles |
Files in This Item:
If it is a zip file, please download the file and unzip it, then open index.html in a browser to view the full text content.