摘要: | Process capability indices have been widely used in the manufacturing industry. Those capability indices, quantifying process potential and performance, are important for any successful quality improvement activities and quality program implementation. Because of the simplicity and easy of understanding, the precision index C-p has gained its popularity for measuring process consistency. However, the quality of data on the process characteristics relies very much on the gauge measurement. Conclusions about capability of the process just only based on the single numerical value of the index are not reliable. In this paper, we not only conduct the performance of the index C-p with gauge measurement errors, but also present adjusted confidence interval bounds and critical values for capability testing purpose of C-p with unavoidable measurement errors. Our research would help practitioners to determine whether the factory processes meet the capability requirement, and make more reliable decisions. |