標題: New sensing technology for detection of the common inhalational anesthetic agent sevoflurane using conducting polypyrrole films
作者: Wu, Ren-Jang
Huang, Yu-Ching
Chavali, Murthy
Lin, Tzu Hsuan
Hung, Shih-Lin
Luk, Hsiang-Ning
土木工程學系
Department of Civil Engineering
關鍵字: sevoflurane;polypyrrole;conducting polymer;UV-photopolymerization;VOC sensor
公開日期: 1-十月-2007
摘要: A new type of gas sensor to measure resistance was developed to detect sevoflurane concentrations at room temperature. The measured FTIR spectrum of sevoflurane vapor was given. The sensing material polypyrrole was synthesized in situ by UV-photopolymerization. The relative resistance variation was 3.9 for a sevoflurane concentration of 1.2%. The sensor response time (60 s) and recovery time (20 s) were very short. Molecular dynamic calculations made for sevoflurane adsorption on polypyrrole revealed formation of a new bond, N-H-F. The bond length was predicted to be in the range of 0.2-0.4 nm. The bond energy was about 7.2 kcal/mol. Sensor responses to the concentrations 0. 1-10% were 1.57-5.9, respectively. (C) 2007 Elsevier B.V. All rights reserved.
URI: http://dx.doi.org/10.1016/j.snb.2007.03.026
http://hdl.handle.net/11536/10302
ISSN: 0925-4005
DOI: 10.1016/j.snb.2007.03.026
期刊: SENSORS AND ACTUATORS B-CHEMICAL
Volume: 126
Issue: 2
起始頁: 387
結束頁: 393
顯示於類別:期刊論文