完整後設資料紀錄
DC 欄位語言
dc.contributor.authorChung, Ying-Chienen_US
dc.contributor.authorHo, Kuo-Lingen_US
dc.contributor.authorTseng, Ching-Pingen_US
dc.date.accessioned2014-12-08T15:14:31Z-
dc.date.available2014-12-08T15:14:31Z-
dc.date.issued2007-03-01en_US
dc.identifier.issn1047-3289en_US
dc.identifier.urihttp://hdl.handle.net/11536/11046-
dc.description.abstractA high H2S concentration inhibits nitrification when H2S and NH3 are simultaneously treated'in a single biofilter. To improve NH3 removal from waste gases containing concentrated H2S, a two-stage biofilter was designed to solve the problem. In this study, the first biofilter, inoculated with Thiobacillus thioparus, was intended mainly to remove H2S and to reduce the effect of H2S concentration on nitrification in the second biofilter, and the second biofilter, inoculated with Nitrosomonas europaea, was to remove NH3. Extensive studies, which took into account the characteristics of gas removal, the engineering properties of the two biofilters, and biological parameters, were conducted in a 210-day operation. The results showed that an average 98% removal efficiency for H2S and a 100% removal efficiency for NH3 (empty bed retention time = 23-180 sec) were achieved after 70 days. The maximum degradation rate for NH3 was measured as 2.35 g N day(-1) kg of dry granular activated carbon'. Inhibition of nitrification was not found in the biofilter. This two-stage biofilter also exhibited good adaptability to shock loading and shutdown periods. Analysis of metabolic product and observation of the bacterial community revealed no obvious acidification or alkalinity phenomena. In addition, a lower moisture content (similar to 40%) for microbial survival and low pressure drop (average 24.39 mm H2O m(-1)) for system operation demonstrated that the two-stage biofilter was energy saving and economic. Thus, the two-stage biofilter is a feasible system to enhance NH3 removal in the concentrated coexistence of H2S.en_US
dc.language.isoen_USen_US
dc.titleTwo-stage biofilter for effective NH3 removal from waste gases containing high concentrations of H2Sen_US
dc.typeArticleen_US
dc.identifier.journalJOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATIONen_US
dc.citation.volume57en_US
dc.citation.issue3en_US
dc.citation.spage337en_US
dc.citation.epage347en_US
dc.contributor.department生物科技學系zh_TW
dc.contributor.departmentDepartment of Biological Science and Technologyen_US
dc.identifier.wosnumberWOS:000244827600012-
dc.citation.woscount13-
顯示於類別:期刊論文


文件中的檔案:

  1. 000244827600012.pdf

若為 zip 檔案,請下載檔案解壓縮後,用瀏覽器開啟資料夾中的 index.html 瀏覽全文。