完整後設資料紀錄
DC 欄位語言
dc.contributor.authorLee, Chung-Hunen_US
dc.contributor.authorWang, Shih-Changen_US
dc.contributor.authorYuan, Chiun-Jyeen_US
dc.contributor.authorWen, Meng-Fangen_US
dc.contributor.authorChang, Ku-Shangen_US
dc.date.accessioned2014-12-08T15:14:53Z-
dc.date.available2014-12-08T15:14:53Z-
dc.date.issued2007-01-15en_US
dc.identifier.issn0956-5663en_US
dc.identifier.urihttp://dx.doi.org/10.1016/j.bios.2006.03.008en_US
dc.identifier.urihttp://hdl.handle.net/11536/11227-
dc.description.abstractDifferent strategies, including palladium electrodeposition (Pd-CV), I'd sputtering (Pd-S) and Nafion-solubilized carbon nanotube casting (Nafion/CNT), were used to modify screen-printed carbon electrodes (SPCEs) for the fabrication of amperometric enzyme biosensors. The electrochemical properties of the bare and modified SPCEs and the optimal conditions for surface modification were determined. The electrochemical response of the bare SPCE to H2O2 under the potential of 0.3 V could be improved about 100-fold by Pd modification by electrodeposition or sputtering. By contrast, the electrochemical response of the bare SPCE was enhanced by only about 11-fold by Nafion/CNT casting. Moreover, the Pd-CV-SPCEs exhibited better reproducibility of electrochemical response (a relative standard deviation (R.S.D.)< 6.0%) than freshly prepared Pds-SPCEs (R.S.D. > 10%). The glucose biosensor fabricated from Pd-modified electrodes could be stored for up to 108 days without loosing significant activity. The Pd-CV-SPCE also showed very reliable signal characteristics upon 50 consecutively repeated measurements of ascorbic acid. The electrocatalytic detection of the Pd-SPCE was combined with additional advantages of resistance to surface fouling and hence good stability. In conclusion, this study demonstrated that deposition of Pd thin film on SPCEs by electrodeposition or sputtering provided superior enhancement of electrochemical properties compared to Nafion/CNT-SPCEs. Despite their high electrochemical response, Pds-SPCEs required an activation process to improve stability and Pd-CV-SPCEs suffered from poor between electrode reproducibility. (c) 2006 Elsevier B.V. All rights reserved.en_US
dc.language.isoen_USen_US
dc.subjectscreen-printed carbon electrodesen_US
dc.subjectelectrodepositionen_US
dc.subjectsputteringen_US
dc.subjectcarbon nanotubeen_US
dc.subjectpalladiumen_US
dc.titleComparison of amperometric biosensors fabricated by palladium sputtering, palladium electrodeposition and Nafion/carbon nanotube casting on screen-printed carbon electrodesen_US
dc.typeArticleen_US
dc.identifier.doi10.1016/j.bios.2006.03.008en_US
dc.identifier.journalBIOSENSORS & BIOELECTRONICSen_US
dc.citation.volume22en_US
dc.citation.issue6en_US
dc.citation.spage877en_US
dc.citation.epage884en_US
dc.contributor.department生物科技學系zh_TW
dc.contributor.departmentDepartment of Biological Science and Technologyen_US
dc.identifier.wosnumberWOS:000243541800014-
dc.citation.woscount47-
顯示於類別:期刊論文


文件中的檔案:

  1. 000243541800014.pdf

若為 zip 檔案,請下載檔案解壓縮後,用瀏覽器開啟資料夾中的 index.html 瀏覽全文。