Full metadata record
DC FieldValueLanguage
dc.contributor.authorLie, YMen_US
dc.contributor.authorLin, TFen_US
dc.date.accessioned2014-12-08T15:16:15Z-
dc.date.available2014-12-08T15:16:15Z-
dc.date.issued2006-07-01en_US
dc.identifier.issn0017-9310en_US
dc.identifier.urihttp://dx.doi.org/10.1016/j.ijheatmasstransfer.2005.11.032en_US
dc.identifier.urihttp://hdl.handle.net/11536/12055-
dc.description.abstractExperiments are conducted here to investigate how the channel size affects the subcooled flow boiling heat transfer and associated bubble characteristics of refrigerant R-134a in a horizontal narrow annular duct. The gap of the duct is fixed at 1.0 and 2.0 mm in this study. From the measured boiling curves, the temperature undershoot at ONB is found to be relatively significant for the subcooled flow boiling of R-134a in the duct. The R-134a subcooled flow boiling heat transfer coefficient increases with a reduction in the gap size, but decreases with an increase in the inlet liquid subcooling. Besides, raising the imposed heat flux can cause a substantial increase in the subcooled boiling heat transfer coefficient. However, the effects of the refrigerant mass flux and saturated temperature on the boiling heat transfer coefficient are small in the narrow duct. Visualization of the subcooled flow boiling processes reveals that the bubbles are suppressed to become smaller and less dense by raising the refrigerant mass flux and inlet subcooling. Moreover, raising the imposed heat flux significantly increases the bubble population, coalescence and departure frequency. The increase in the bubble departure frequency by reducing the duct size is due to the rising wall shear stress of the liquid flow, and at a high imposed heat flux many bubbles generated from the cavities on the heating surface tend to merge together to form big bubbles. Correlation for the present subcooled flow boiling heat transfer data of R-134a in the narrow annular duct is proposed. Additionally, the present data for some quantitative bubble characteristics such as the mean bubble departure diameter and frequency and the active nucleation site density are also correlated. (c) 2006 Elsevier Ltd. All rights reserved.en_US
dc.language.isoen_USen_US
dc.titleSubcooled flow boiling heat transfer and associated bubble characteristics of R-134a in a narrow annular ducten_US
dc.typeArticleen_US
dc.identifier.doi10.1016/j.ijheatmasstransfer.2005.11.032en_US
dc.identifier.journalINTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFERen_US
dc.citation.volume49en_US
dc.citation.issue13-14en_US
dc.citation.spage2077en_US
dc.citation.epage2089en_US
dc.contributor.department機械工程學系zh_TW
dc.contributor.departmentDepartment of Mechanical Engineeringen_US
dc.identifier.wosnumberWOS:000238269800007-
dc.citation.woscount28-
Appears in Collections:Articles


Files in This Item:

  1. 000238269800007.pdf

If it is a zip file, please download the file and unzip it, then open index.html in a browser to view the full text content.