完整後設資料紀錄
DC 欄位語言
dc.contributor.authorChen, Tzu-Mingen_US
dc.contributor.authorTsai, Chuen-Jinnen_US
dc.contributor.authorYan, Shaw-Yien_US
dc.contributor.authorLi, Shou-Nanen_US
dc.date.accessioned2015-07-21T11:21:12Z-
dc.date.available2015-07-21T11:21:12Z-
dc.date.issued2014-11-05en_US
dc.identifier.issn1383-5866en_US
dc.identifier.urihttp://dx.doi.org/10.1016/j.seppur.2014.08.032en_US
dc.identifier.urihttp://hdl.handle.net/11536/123915-
dc.description.abstractAn efficient wire-to-plate single-stage wet electrostatic precipitator (WESP) was designed and tested to control nanoparticles, submicron and micron-sized particles emitted from semiconductor manufacturing processes. Tungsten-wires of 0.36 mm in diameter were used as discharge electrodes and a fixed voltage of -15 kV was supplied to generate the electric field and corona ions. Fine water mist at room temperature was used to quench the high temperature exhaust gas to enhance particle condensation growth and improve the collection efficiency of nanoparticles. Experimental results showed that without fine water mist, nanoparticle collection efficiency was 67.9-92.9%, which was greatly enhanced to 99.2-99.7% when the WESP was operated with fine water mist. A predictive method was developed to calculate the particle collection efficiency equation eta(%) in the form as eta(%) = [1 - exp(-alpha(N-De)(beta) + gamma)] x 100%, in which alpha, beta and gamma are regression coefficients and N-De is the Deutsch number. Good agreement was obtained between present predictions and experimental data. For longer term operation, the periodic wall-cleaning water was used to clean discharge electrodes and collection electrodes regularly. In the field tests, the total collection efficiencies (40 <= d(p) <= 8100 nm) of the WESP were found to maintain greater than 98.7% and 97.3% for continuous operation for 35 and 22 day at fab A and fab B, respectively. (C) 2014 Elsevier B.V. All rights reserved.en_US
dc.language.isoen_USen_US
dc.subjectWet electrostatic precipitatoren_US
dc.subjectDeutsch-Anderson equationen_US
dc.subjectHeterogeneous condensationen_US
dc.subjectParticle controlen_US
dc.titleAn efficient wet electrostatic precipitator for removing nanoparticles, submicron and micron-sized particlesen_US
dc.typeArticleen_US
dc.identifier.doi10.1016/j.seppur.2014.08.032en_US
dc.identifier.journalSEPARATION AND PURIFICATION TECHNOLOGYen_US
dc.citation.volume136en_US
dc.citation.spage27en_US
dc.citation.epage35en_US
dc.contributor.department環境工程研究所zh_TW
dc.contributor.departmentInstitute of Environmental Engineeringen_US
dc.identifier.wosnumberWOS:000344831100004en_US
dc.citation.woscount0en_US
顯示於類別:期刊論文


文件中的檔案:

  1. 000344831100004.pdf

若為 zip 檔案,請下載檔案解壓縮後,用瀏覽器開啟資料夾中的 index.html 瀏覽全文。