完整後設資料紀錄
DC 欄位語言
dc.contributor.authorSun, Shih-Hungen_US
dc.contributor.authorLee, Mon-Juanen_US
dc.contributor.authorLee, Yun-Hanen_US
dc.contributor.authorLee, Weien_US
dc.contributor.authorSong, Xiaolongen_US
dc.contributor.authorChen, Chao-Yuanen_US
dc.date.accessioned2019-04-03T06:40:23Z-
dc.date.available2019-04-03T06:40:23Z-
dc.date.issued2015-01-01en_US
dc.identifier.issn2156-7085en_US
dc.identifier.urihttp://dx.doi.org/10.1364/BOE.6.000245en_US
dc.identifier.urihttp://hdl.handle.net/11536/124247-
dc.description.abstractThe use of fluorescence is ubiquitously found in the detection of immunoreaction; though with good sensitivity, this technique requires labeling as well as other time-consuming steps to perform the measurement. An alternative approach involving liquid crystals (LCs) was proposed, based on the fact that an immunocomplex can disturb the orientation of LCs, leading to an optical texture different from the case when only antigen or antibody exists. This method is label-free, easy to manipulate and lowcost. However, its sensitivity was low for practical usage. In this study, we adopted a high-birefringence liquid crystal (LC) to enhance the sensitivity for the immunodetection. Experiments were performed, targeting at the cancer biomarker CA125. We showed that the larger birefringence (Delta n = 0.33 at 20 degrees C) amplifies the detected signal and, in turn, dramatically improves the detection limit. To avoid signal loss from conventional rinsing steps in immunodetection, CA125 antigen and antibody were reacted before immobilized on substrates. We studied the specific binding events and obtained a detection limit as low as 1 ng/ml. The valid temperature ranges were compared by using the typical single-compound LC 5CB and the high-birefringence LC mixture. We further investigated time dependency of the optical textures and affirmed the capability of LC-based immunodetection in distinguishing between specific and nonspecific antibodies.en_US
dc.language.isoen_USen_US
dc.titleImmunoassays for the cancer biomarker CA125 based on a large-birefringence nematic liquid-crystal mixtureen_US
dc.typeArticleen_US
dc.identifier.doi10.1364/BOE.6.000245en_US
dc.identifier.journalBIOMEDICAL OPTICS EXPRESSen_US
dc.citation.volume6en_US
dc.citation.issue1en_US
dc.citation.spage245en_US
dc.citation.epage256en_US
dc.contributor.department影像與生醫光電研究所zh_TW
dc.contributor.departmentInstitute of Imaging and Biomedical Photonicsen_US
dc.identifier.wosnumberWOS:000347474800022en_US
dc.citation.woscount13en_US
顯示於類別:期刊論文


文件中的檔案:

  1. c306a89fff1ad0223bc8c74c4e0e73c6.pdf

若為 zip 檔案,請下載檔案解壓縮後,用瀏覽器開啟資料夾中的 index.html 瀏覽全文。