完整後設資料紀錄
DC 欄位 | 值 | 語言 |
---|---|---|
dc.contributor.author | Wang, Chi-Chuan | en_US |
dc.date.accessioned | 2015-07-21T11:20:42Z | - |
dc.date.available | 2015-07-21T11:20:42Z | - |
dc.date.issued | 2014-12-22 | en_US |
dc.identifier.issn | 1359-4311 | en_US |
dc.identifier.uri | http://dx.doi.org/10.1016/j.applthermaleng.2014.08.012 | en_US |
dc.identifier.uri | http://hdl.handle.net/11536/124255 | - |
dc.description.abstract | In this study, an overview of the system performance of R-1234yf in association with R-134a is carried out. Based on the existing researches, it is found that the COP and heat capacity of R-134a system may suffer from direct drop-in replacement of R-1234yf. The deterioration is around 0-27% depending on the operational conditions. With the introduction of internal heat exchanger, ejector, expander, or adjustment of the thermal expansion valve, the deterioration can be relieved, and a comparable performance becomes likely. For the heat transfer performance in the evaporator, R-1234yf is almost comparable with that of R-134a. However, the performance in the condenser is inferior to R-134a. The phenomenon may be quite severe for a water cooled condenser since the dominant thermal resistance may fall in the refrigerant side. The volumetric efficiency of R-1234yf system is slightly lower than that of R-134a due to higher frictional drop of R-1234yf. For the same thermal expansion valve for controlling the suction superheat, it appears that higher suction superheat may occur for R-1234yf refrigerant. Hence further adjustment of spring in the valve is required for soft optimization. (C) 2014 Elsevier Ltd. All rights reserved. | en_US |
dc.language.iso | en_US | en_US |
dc.subject | R-1234yf | en_US |
dc.subject | R-134a | en_US |
dc.subject | System performance | en_US |
dc.subject | Heat pump | en_US |
dc.subject | Air-conditioning | en_US |
dc.title | System performance of R-1234yf refrigerant in air-conditioning and heat pump system - An overview of current status | en_US |
dc.type | Article | en_US |
dc.identifier.doi | 10.1016/j.applthermaleng.2014.08.012 | en_US |
dc.identifier.journal | APPLIED THERMAL ENGINEERING | en_US |
dc.citation.volume | 73 | en_US |
dc.citation.spage | 1412 | en_US |
dc.citation.epage | 1420 | en_US |
dc.contributor.department | 機械工程學系 | zh_TW |
dc.contributor.department | Department of Mechanical Engineering | en_US |
dc.identifier.wosnumber | WOS:000347502300003 | en_US |
dc.citation.woscount | 1 | en_US |
顯示於類別: | 期刊論文 |