完整後設資料紀錄
DC 欄位 | 值 | 語言 |
---|---|---|
dc.contributor.author | Hsu, Li-Chieh | en_US |
dc.contributor.author | Cion, Sian-Wun | en_US |
dc.contributor.author | Lin, Kuo-Wei | en_US |
dc.contributor.author | Wang, Chi-Chuan | en_US |
dc.date.accessioned | 2015-07-21T08:28:39Z | - |
dc.date.available | 2015-07-21T08:28:39Z | - |
dc.date.issued | 2015-03-01 | en_US |
dc.identifier.issn | 0735-1933 | en_US |
dc.identifier.uri | http://dx.doi.org/10.1016/j.icheatmasstransfer.2015.01.007 | en_US |
dc.identifier.uri | http://hdl.handle.net/11536/124546 | - |
dc.description.abstract | In this study, the effect of inclination on the two-phase convective boiling heat transfer characteristics of HFE-7100 is investigated experimentally in a multiport micro-channel having a hydraulic diameter of 440 mu m. The corresponding mass flux is 100 and 200 kg m(-2) S-1, respectively. The inclinations include -90, -45, 0, 45, and 90 degrees with respect to the horizon. Test results show that normally the heat transfer coefficient for upward arrangements is superior to those of downward arrangement at a supplied heat flux of 25 kW m(-2). Yet this is applicable for G = 100 or 200 kg m(-2) s(-1). The heat transfer coefficients increase with the vapor quality and peak again at a vapor quality of 0.6, suggesting a controlled mechanism of convective boiling. With the rise of heat flux to 40 kW m(-2), it appears that nucleate boiling may impose appreciable effect on the heat transfer mechanism. For G = 100 kg m(-2) s(-1), the heat transfer coefficients for all arrangements are insensitive to change of vapor quality (x < 0.6), implicating that nucleate boiling is in control. Analogous results prevail for G = 200 kg m(-2) s (-1). Six heat transfer correlations are used to predict experimental data in different orientation. It appears that the Kandlikar correlation shows the best-predictive ability against the present data with an overall mean deviation of 29.04% (C) 2015 Elsevier Ltd. All rights reserved. | en_US |
dc.language.iso | en_US | en_US |
dc.subject | Dielectric fluid | en_US |
dc.subject | Inclination | en_US |
dc.subject | Micro-channel | en_US |
dc.subject | Convective boiling | en_US |
dc.title | An experimental study of inclination on the boiling heat transfer characteristics of a micro-channel heat sink using HFE-7100 | en_US |
dc.type | Article | en_US |
dc.identifier.doi | 10.1016/j.icheatmasstransfer.2015.01.007 | en_US |
dc.identifier.journal | INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER | en_US |
dc.citation.volume | 62 | en_US |
dc.citation.spage | 13 | en_US |
dc.citation.epage | 17 | en_US |
dc.contributor.department | 機械工程學系 | zh_TW |
dc.contributor.department | Department of Mechanical Engineering | en_US |
dc.identifier.wosnumber | WOS:000351656400002 | en_US |
dc.citation.woscount | 0 | en_US |
顯示於類別: | 期刊論文 |