完整後設資料紀錄
DC 欄位 | 值 | 語言 |
---|---|---|
dc.contributor.author | Chen, Ya-Chen | en_US |
dc.contributor.author | Hsiao, Tzu-Chien | en_US |
dc.date.accessioned | 2015-07-21T08:30:51Z | - |
dc.date.available | 2015-07-21T08:30:51Z | - |
dc.date.issued | 2015-01-01 | en_US |
dc.identifier.isbn | 978-3-319-11127-8 | en_US |
dc.identifier.issn | 1680-0737 | en_US |
dc.identifier.uri | http://dx.doi.org/10.1007/978-3-319-11128-5_106 | en_US |
dc.identifier.uri | http://hdl.handle.net/11536/124982 | - |
dc.description.abstract | According to ventilation of acceptable indoor air quality (IAQ), the air carbon dioxide concentration (C-CO2) and air temperature (T-a) increase with human in poor ventilation. The main source of CO2 pollution indoor is human respiration. This study simulates a poor ventilation condition and 10 volunteers participate with non-mask method to study the physiological responses in three C-CO2 levels. Facial temperature (T-f), saturation of percentage oxygen (SpO(2)), and electrocardiography (HR) were spontaneously acquired while subjects were inside an airtight room. Analytical results indicate SpO(2) decreased as C-CO2 increased. Those results further demonstrate a positive correlation between C-CO2/HR and C-CO2/T-f, implying that the central-chemoreflex can stimulate the respiratory system since SpO(2) variance and increased HR can promote pulmonary gas exchange. Notably, temperature difference in T-f and T-a increased under low C-CO2 and then reversed and stabilized inference the antagonistic pattern accelerated rapidly initially and decelerated finally stabilized. These findings also imply that the internal body responded to changes in the external environment rapidly, attempted to homeostasis, and reached equilibrium slowly. Variations of C-CO2 and T-a can be modeled by equations. Results of this study prove that IAQ affects physiological responses in the symbiotic relationship between the human body and surrounding environment. | en_US |
dc.language.iso | en_US | en_US |
dc.subject | indoor air quality | en_US |
dc.subject | carbon dioxide concentration | en_US |
dc.subject | facial temperature | en_US |
dc.subject | electrocardiography | en_US |
dc.subject | poor ventilation room | en_US |
dc.title | Physiological Responses to Different CO2 Levels in Poor Ventilation Room | en_US |
dc.type | Proceedings Paper | en_US |
dc.identifier.doi | 10.1007/978-3-319-11128-5_106 | en_US |
dc.identifier.journal | 6TH EUROPEAN CONFERENCE OF THE INTERNATIONAL FEDERATION FOR MEDICAL AND BIOLOGICAL ENGINEERING | en_US |
dc.citation.volume | 45 | en_US |
dc.citation.spage | 423 | en_US |
dc.citation.epage | 426 | en_US |
dc.contributor.department | 資訊工程學系 | zh_TW |
dc.contributor.department | Department of Computer Science | en_US |
dc.identifier.wosnumber | WOS:000349454200106 | en_US |
dc.citation.woscount | 0 | en_US |
顯示於類別: | 會議論文 |