dc.description.abstract本研究以電力負載上限內,將延長線以無綑綁、4折綑綁、8折綑綁方式,應用紅外線熱像儀量測溫升變化,探討負載範圍內延長線經綑綁後是否有潛在溫升風險。zh_TW
dc.description.abstractIn this study, in the electric load limit will be extended to non-tied bundle, tied 4 fold, tied 8 fold bundled manner, the application of infrared thermal image amount of temperature rise, and to explore whether an extension cord tied after potential risks rise.en_US